Loading...
HomeMy WebLinkAboutUP 06-0022FILE NO.: PROJECT TYPE: APN: APPLICANT ADDRESS: PHONE: OWNER: ADDRESS REPRESENTATIVE: ADDRESS: s PROJECT SUMMARY SHEET UP 07-06 Use Permit 072-070-197 Clearwire LLC 381 South Lexington Dr 530-878-9117 Suite 103, Folsom, CA 95630 Leland Stanford Masonic Temple Association PO Box 784, Chico, CA 95927 Epic Wireless/ David Wiltsee 381 South Lexington Dr. Suite 103, Folsom, CA 95630 PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound LOCATED: on the north side of West East Ave., 1300'(0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) PROPERTY ZONED: A-5 (Agricultural, 5 -acre parcels) GENERAL PLAN DESIGNATION: OFC (Orchard & Field Crops) TOWN/AREA: Chico 1. 2. 4. 5. 6. 7. 8. 9. 10 11 12 13 14 15 16. 17. 18. 19. 20. 21. Application accepted: 9/7/2006 Amount: $ 3550.5 Receipt #: 456687, 456688 Assigned To: Chris Tolley Comments sent to: Public Works Director, Environmental Health, Assessor, LAFCo, Agricultural Commissioner, CDF, Building Manager, County Counsel Sent to Inter -Departmental Review Committee (IDR): Status Letter sent to applicant: Date scheduled for IDR: 9/27/2006 Comments received from: Rezone Petition Signatures Checked: Mailing List/Lead-in Sheet: Environmental Determination: Clearinghouse circulation required: Yes No Date Sent to SCH: State Clearinghouse No. Categorical Exemption-CEQA# Negative Declaration Mitigation Negative Declaration Environmental Impact Report Gen. Rule Ex. — CEQA # Other De Minimis: Subject to Fish & Game: Staff Recommends: Approval Denial �� f Date Notices Mailed: Neg Dec. Hearing Number of Notic . rj Newspaper Publication Date: Neg Dec. Hearing O (SI P G B Planning Commission Hearing(s): Action taken:— - Board of Supervisors' Hearing(s): Action taken: Board Resolution No.: Ordinance No: Adopted: Type Use Permit, Send for signature: N.O.E. / N.O.D. / APPENDIX G: Fish & Game Fees Paid: Yes No Send letter if approval/denial to applicant/representative: Copies to Environmental Health, Building, Land Development: Assessor's Memo: Copy of Use Permit to GIS: 0, . 0 AGENT AUTHORIZATION TO: Butte County, Department of Development Services: Clearwire LLC (Agent: EPIC Wireless Group (David Wiltsee)) Phone Number (530) 878-9117 Print Name 381 South Lexington Dr., Ste 103, Folsom, CA 95630 Mailing Address is hereby authorized to process the application for Clearwire LLC on my property, identified as Butte County Assessor Parcel Number (APN) 042-070-197. This authorization allows representation for all applications, hearings, appeals, etc. and to sign all documents necessary for said processing, but not including document(s) relating to record title interest. Owner(s) of Record: (sign and print name) C'ca rzk M4, -J O.S ZA77 W AA . Print Signature Print Name Signature Architect and/or Engineer: Max Engineering by: Sam Lamendola Phone Number (717) 873-0466 Print Name of Architect/Engineer 9000 Southwest Freeway, Suite 410. Houston, TX 77074 Mailing Address FOR OFFICE USE ONLY Verify: Date Received: �%� � �� (� Total Amount Received: AP Number(s) � egal Description Owners Authorization '® Zoning Requirements Project Description ,Copies of plot plan Taken by: C , �',� 1 Receipt No. PW/LD Plan �c/�?0,EbE.H. CDF 70o NOD/NOE Fees AG. � ❑ Archaeological Resources Project Review Fee6$ 0.00 (paid by a separate check, necessary for all discretionary land use projects requiring an environmental review, made payable to the Northeast Information Center) Payment of the currently required Application Fee and/or Deposit (any unused portion of a deposit) will be returned upon final action. Current fee for this application i 7�, �) ,� �. S �� as of Make check payable to "Butte County Treasurer". Revised 1/27/05 CADocuments and Settings\Bryon\Local Setting\Temporary Internet Fi1es\0LK73\CA-CHC01 I Butte Uniform Application.doc Page 2 of 4 COUNTY OF BUTTE ENVIRONMENTAL INFORMATION FORM (To be completed by Project Applicant) GENERAL INFORMATION: 1. Name and address of owner, and/or deve 'PGt_:: lT e 7')A✓/7) �i�i/LISW Date Filed and/or project sponsor: n- Ess, (29/Qc p 2. Address of project: .moi 44� . Ci4 9�>'73 Assessor's Parcel Number: ®x/ ,� 72 � - /97 3. Name, address, and telephone number of person to be contacted concerning this project: D.4V1V 1,0/LTSE d!5 -_P/C /if%/.R�LESS cF/ 7ZiA/ del. , ST� 17):3. C4 �Rref,-3:::� 6-3x) .P-7oo-5//7 4. List and describe any other related permits and other public approvals required for this project, including those required by city, regional, state and federal agencies: /ly"e- 5. Existing general plan designation: 6. Existing zoning district: A-5 7. How is land currently used? 11%IASbNiG L50244E al7d r0Ci),2 6R00A.0 8. Proposed use of site (Project for which this form is filed): C_DGLOC/-�T�.�i +t!T�iilRl�s �%N X1�'77it/G Tdiw9_R ' �/�I �7 to C3�-f3��ET" /i(! n.�iG C/1r�lr �AIA If Project Description: L� ,Q� 7� - 9. Site size: (Acres/Sq. Feet) 10. Off-street parking spaces: Full size: `10-. Compact: '�1 Total: 11. Plans attached: Yes No 12. Proposed development schedule _ OpAl2LET_ eG/✓,577120C 7-101J I%lkrg OF �5'cS'U /c AC_R0rL!7i/16 !D�17- 13. Assgciated projects ,T//!l/!_-R_ AA/ {Z71/Wfl Si'T�S C/�/CO; 14. Anticipated incremental or phased development ■ Butte County Department of Development Services ■ Planning Division 0 Attach description of project containing the following information: 15. If residential, include the number of units, schedule of unit sizes, range of sale prices or rents, and type of household size expected. y. 1A 16. If commercial, indicate the type, whether neighborhood, city or regionally oriented, square footage of sales area and loading facilities. NIX 17. If industrial, indicate type, estimated employment per shift, and loading facilities -40 18. If institutional, indicate the major function, estimated employment per shift, estimated occupancy, loading facilities, and community benefits to be derived from the project. ILI/A 19. If the project involves a minor variance, conditional use, rezoning application, or any development permits, state this and indicate clearly why the application is required. If permits have already been issued, please attach as Exhibit Are the following items applicable to the project or its effects? Discuss below all items checked yes (attach additional sheets as necessary). YES NO 20. Change in existing features of any hills, buttes, canyons Change in dust, ash, smoke, fumes or odors in vicinity. _ or substantial alteration of ground contours. 25. 21. Change in scenic views or vistas from existing residential areas or public lands or roads. or quantity, or alteration of existing drainage patterns. 22. Change in pattern or character of general area of project. _ 26. 23. Significant amounts of solid waste or litter. X 24. Change in dust, ash, smoke, fumes or odors in vicinity. _ 25. Change in bay, lake, river, stream or ground water quality or quantity, or alteration of existing drainage patterns. 26. Substantial change in existing noise or vibration levels X in the vicinity. 27. Site on filled land or on slopes of 10 percent or more. 28. Use of, or disposal of potentially hazardous materials, flammable \/ such as toxic substances, or explosives. 29. Substantial change in demand for municipal services (police, fire, water, sewage, etc. including special districts). _ 30. Substantially increase fossil fuel consumption (electricity, oil, natural gas,. etc.). 31. Relationship to a larger project or series of projects. X ■ Butte County Department of Development Services ■ Planning Division ■ 2 Environmental Setting: (Attach brief description) 32. Describe the project site as it exists before the project, including information on topography, soil stability, plants and animals, and any cultural, historical, or scenic aspects. Describe any existing structures on the site and the use of the structures. Attach photographs of the site. Snapshots or Polaroid photos will be accepted. 33. Describe the surrounding properties, including information on plants and animals and any cultural, historical, or scenic aspects. Indicate the type of land use (residential, commercial, etc.), intensity of land use (one - family, apartment houses, shops, department stores, etc.), and scale of development (height, frontage, set- back, rear yard, etc.). Attach photographs of the vicinity. Snapshots or Polaroid photos will be accepted. Certification I hereby certify that the statements furnished above and in the attached exhibits present the data and information required for this initial evaluation to the best of my ability, and that the facts, statements, and information presented are true and correct to the best of my knowledge and belief. 71�-7106 ��_ Date Signature 3Z. G'i�w0,1 ,esrc�ei. .1'.Vif 1e- a 33, Ac, -Mo D/'-cha rj�zce.c4- -lo sig k:\planning\forms\submittal\env.doc ■ Butte County Department of Development Services ■ Planning Division ■ 3 A • • USE PERMIT APPLICATION PACKET CHECKLIST This checklist is designed to assist applicants in making sure all necessary information is included in their application packet. Please include this checklist along with your submittal. Applicant Planner l . ❑ ❑ Complete a Pre -Application. Review with the Environmental Health Division for on- site sewage disposal requirements for the proposed use. The Environmental Health Division charges a $202.00 fee for this review. (This fee will be applied towards the $404.00 Environmental Health Division fee required at the time of application submittal). A/0 f re� u4,Ysc1 - 6(,,1-e /,7� - /Ue, -v e-4 e ev J ewe.- 2 . A completed, signed, Uniform Application and Environmental Information form. If the. application is signed by an agent for the property owner, an went authorization form must be submitted along with the Uniform Application. The application shall not be accepted unless signed by the owner or authorized agent. ,g, -.e{ 3. -Payment of the currently required Application Fee and/or Deposit (Any unused portion of the deposit will be returned upon final action, if any remains.) (Planner advises applicant) 4. Ld Thirty-five 35) copies of plans which shall include a detailed site plan drawn to scale. All plans shall be drawn on uniform size sheets no greater than 24" x 36". The finished plans shall be folded to 8 %2" x 11". The detailed site plan must include: a . Er Name and address of Applicant, Engineer and/or person who prepared the plan b . U Property lines and lot dimensions c. 0 Assessor Parcel Number(s) and the street address. d. Proposed use and/or uses of the property. e . Er ❑ Proposed landscaping plan, if applicable. f. EJ Ef Dimensioned locations of existing and proposed improvements on the property_ (including, but not limited to, buildings, driveways, parking areas, wells, septic tanks and leach fields):. IF INSUFFICIENT INFORMATION IS SUBMITTED, THE APPLICATION WILL BE DEEMED INCOMPLETE. 5. g. Distances from any -significant natural and constructed features of the property, such as streets, access roads, streams, rock outcroppings, major tree stands, storm drains, bodies of water, railroads, to the property lines. h. LJ Location of all slope banks, ponds, creeks, buttes, sloughs, rock outcroppings, natural drainage courses, irrigation canals and existing vegetation worthy of consideration for preservation, such as oak trees. 1. Any existing faults or fractures and geologic hazards. J. E LJ North arrow and scale of drawing. All plans shall be drawn to an engineering scale with the preferred scale of 1" = 20', with a north arrow preferably oriented to the top of sheet. k. All plans must be clear and legible. Er One copy of 8 %' x 11" transparency reduction of the detailed site plan. 6. LSI ld A vicinity map showing closest major cross streets, zoning and existing land use. After a meeting with a Butte County Planner the following checked items will be required to be submitted at the time of application: (optional) 7. ❑ ❑ One (1) set of colored.plans mounted on foam boards, which shall include an illustrative site plan, illustrative building elevations, and any necessary cross-sections. Portions of this requirement may be waived by the Planning Manager. Portions waved ❑ YES ❑ NO 8. ❑ ❑ One (1) full size reproducible sepia for each sheet in the plan set of the detailed site plan. 9. ❑ F-11 Building materials on a sample board, 8 %z" X 11 ". 10. ❑ ❑ Detailed site plan including the following: a. ❑ ❑ Building setbacks from the ultimate road right-of-way (front, rear, sides). b. ❑ - ❑ C. ❑ ❑ Proposed and existing on-site driveways and/or roads. Location, height, and materials of walls and fences (sections may be required). - - --- - - --_ -_- ----- -- 1- r T%T T%T7 ^ /Lr%TATrV-aXDT RTC d. ❑ El All driveways, drawn to scale, on adiacent and across the street properties within 100 feet of the subject site. e. ❑ ❑ Existing curbs, gutters, sidewalks and existing paving widths on-site or within 100 feet of the site, on adjacent and across the street properties. f. ❑ ❑ Typical street section(s). g. ❑ ❑ Nearest cross streets on both sides with plus or minus distances from subject site. h. ❑ ❑ Approximate location of all buildings within 100 feet, on adjacent properties. I. ❑ ❑ Proposed method of sewer and water connection or alternative method of sewage disposal and potable water supply. j . ❑ ❑ Existing and nearest fire hydrants. k. ❑ ❑ Access, both pedestrian and vehicular, showing service areas and points of ingress and egress. i. ❑ ❑ Internal circulation pattern. m. ❑ ❑ Elevation contours, at a minimum per USGS maps. 11. ❑ ❑ Illustrative. Site Plan The plan should include a graphic scale and north arrow, all proposed and existing improvements, landscape concepts such as earth mounding and meandering walkways, walls, ground cover, trees, shrubs, shadows, paving and other elements as maybe necessary to illustrate the site plan. (Dimensions maybe excluded from this plan.) 12. ® ❑ Conceptual Grading Plan Items to be shown include: a. ❑ ❑ Natural areas to be preserved. b. 11 ❑ Proposed cut and fill areas in contrasting colors of zipatone pattern.. 0 • c. ❑ ❑ Existing and proposed contours within 100 feet of project boundaries. d. ❑ ❑ Proposed drainage and flood control facilities. e. .❑ ❑ Erosion control measures (e.g. -.slope landscaping). f. ❑ ❑ Natural drainage. g. ❑ ❑ Elevations and finished contours. h. ❑ ❑ Location of retaining walls, drainage channels and existing structures. - I. ❑ ❑ Location, elevation and size of proposed building pads. 13. ❑ � ❑ Illustrative Building Elevations Illustrative building elevations showing all sides of existing and proposed buildings and structures. Illustrative building elevations means architectural elevations showing typical materials to be used, trees, landscaping and shadows to give the elevations graphic dimension. Additional information may be required in order to clarify, amplify, correct or otherwise supplement the above submittal information or to complete any required environmental review documents, as deemed necessary by the Department of Development Services, Public Works, Environmental Health Division, Butte County Fire Department, or Agriculture Commissioner. Signature: Applicant/Repres tative L 01C Gt% Signature: 2:52 4 Planner Receiving Application KAFORMSTLANNING FORMS\usepermitchecUstdoc Revised 2/1/05 Date: 27-7 lee, Date: TlP; naeT TrrIT . T YMPORMATTOW ig Si IRM M7ED. THE APPLICATION WILL BE DEEMM INCOMPLETE. � FILE COPY � RESOLUTION NO. PC 06-65 A RESOLUTION OF THE BUTTE COUNTY PLANNING COMMISSION APPROVING USE PERMIT 06-0022 WHEREAS, the Planning Commission has considered Use Permit 06-0022 for Clearwire, LLC, in accordance with Chapter 24, Section 45; Use Permits, of the Butte County Code on Assessor's Parcel Number 042-070-197; and WHEREAS, the Planning Commission has determined that project is categorically exempt under Section 15311 in accordance with the California Environmental Quality Act; and WHEREAS, said Use Permit was referred to various affected public and private agencies, County departments, and referral agencies for review and comments; and WHEREAS, the Use Permit was considered. at a duly noticed public hearing held on November 30,2006; and WHEREAS, the Planning Commission has considered a report from the Planning Division and public comments. NOW, THEREFORE, BE IT RESOLVED, that the Planning Commission: I. Finds that this project is exempt from the provisions of the California Environmental Quality Act under Section 15311. Section 15311 consists of construction of minor structures accessory (appurtenant) to existing facilities. Antennas placed on an existing communications lattice tower are considered to be accessory structures. A. Because the project is exempt from the provisions of CEQA, the payment of fees pursuant to Fish and Game Code Section 711.4 and 14 CCR 753.5 is not required. B. The custodian of the record is the Department of Development Services. The location of the record is 7 County Center Drive, Oroville CA 95965. II. Makes the following Use Permit findings: A. The proposed location, size, design, and operating characteristics of the proposed use are in accordance with the purpose of this Ordinance, the purpose of the zone in which the site is located, the Butte County General Plan, and the development policies and standards of the County because: Conditions of approval have been applied to this project pursuant to the applicable requirements of Zoning Code Section 24-262 (Wireless Communication Facilities). The project is in accordance with the purpose of the A-5 Zone and the Butte County General Plan land use designation Orchard and Field Crops, in which the land lies. The Orchard and Field Crops land use designation allows public utilities as Secondary Uses. The A- 5 zone allows collocations with approval of a Use Permit when the facilities that fall within 1, 000 feet of the zones identified in the "Permit Requirements " table located in section 24-262(d). 1 B. The location, size, design, and operating characteristics of the proposed use would be compatible with, and would not adversely affect, or be detrimental to adjacent uses, residents, buildings, structures, or natural resources, with consideration given to: 1. Harmony in scale, bulk, coverage, and density: The proposed antennas and microwave dishes would not increase the height of the existing communications lattice tower or extend horizontally beyond the existing vertical plane. 2. The availability of public facilities, services and utilities: Electrical power service is already established to the property and no additional services or utilities are required. A water source and a sewage disposal system are not required. 3. The harmful effect, if any, upon desirable neighborhood character: The project site is already developed with a 130 foot tall communications lattice tower and accessory ground mounted equipment cabinets and shelters. The radio-frequency emissions from the existing and proposed antennas and microwave dishes would meet FCC standards for public exposure. The proposed antennas would not result in a significant visual impact to the neighborhood in that the new antennas and mounting hardware would be painted to match the color of the existing tower. 4. The generation of traffic and the capacity and physical character of surrounding streets: Only a minor amount of vehicle traffic would be generated during installation of the antennas, microwave dishes and equipment cabinet. The project would result in approximately one to two site visits per month by maintenance personnel. West East Avenue, which would provide access for the project site, would not be impacted by this increase in vehicular traffic. 5. The suitability of the site for the type and intensity of use or development which is proposed: The site is ideally suited for the project because the proposed antennas and microwave dishes would be mounted on an existing communications lattice tower. 6. Any other relevant impact of the proposed use: The Planning Division has circulated the proposed communication facility application to County Agencies and has received no evidence that the use would cause any other relevant impact. C. Based on the above findings, the proposed location, size, design, and operating characteristics of the proposed use and the conditions under which it would be operated or maintained would not be detrimental to the public health, safety or welfare, or injurious to properties or improvements in the vicinity. 2 • • D. The proposed use will comply with each of the applicable provisions of Butte County Code Chapter 24, Section 262. E. This project would place antennas on an existing communications lattice tower, which eliminates the need for a new communications tower/monopole to be erected elsewhere in the project area. F. The radio-frequency emissions generated by the antennas on the communications lattice tower would be below the public exposure limits set by the Federal Communications Commission for wireless communication facilities. G. The proposed antennas and microwave dishes would not create any impacts to aircraft operations because they will not increase the height of the existing communications lattice tower nor extend horizontally beyond the existing antennas. H. Wireless telephone services are regulated by the California Public Utilities Commission and are considered to be a public use. M. Approves Use Permit 06-0022 for Clearwire, LLC, subject to the conditions as set forth in the attachment Exhibit A to the resolution. DULY PASSED AND ADOPTED this 30th Day of November, 2006, the following vote: AYES: Commissioners Marin, Leland, Lambert, Wilson, and Chairman Nelson NOES: No one ABSENT: No one ABSTAIN: No one CHUCK NELSON, Chairman Planning Commission County of Butte, State of California ATTEST: L RICHARDSON, Secretary Planning Commission County of Butte, State of California 3 • EXHIBIT A USE PERMIT BUTTE COUNTY PLANNING COMMISSION DATE: • (Certified Mail Rec.) UP06-0022 PERMIT NO. 042-070-197 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Clearwire, LLC is hereby granted a Use Permit in accordance with application filed to collocate four pannel antennas and four microwave dishes at a height of 113 - feet within 1,000 feet of designated residential zones. Approval is also granted for the associated ground equipment and Global Positioning System antenna. The project site is zoned A-5 and is designated as Orchard and Field Crops by the Butte County General Plan. 1. Failure to comply with the conditions specified herein as ' the basis for approval of application and issuance of permit constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Sec. 24-45. 2. Unless otherwise provided for in a special condition to this Use Permit, all conditions must be completed prior to or concurrently with the establishment of the granted use. The use granted by this permit must be established within 24 months of the delivery of the countersigned permit to the Permittee. Minor changes may be approved administratively by the Directors of Development Services, Environmental Health, or Public Works upon receipt of a substantiated written request by the applicant, or their respective designee. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. 4. If any use for which a Use Permit has been granted is not established within two. years of the date of receipt of the countersigned permit by the Permittee, the permit shall become null and void and reapplication and a new permit shall be required to establish the use. 5. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Permittee. 0 Conditions of Approval: Planning Division 1. The project site shall be developed in accordance with the approved project site plan and the conditions contained herein. Said site plan is on file in the Planning Division, is identified as "Attachment D" and date-stamped September 7, 2006, and is incorporated herein by this reference. 2. The new antennas, microwave dishes and mounting hardware shall be painted to match the color scheme of the existing tower. 3. The installation of the Facility shall comply with all applicable building and electrical codes. The Facility operator shall submit certification from a registered structural engineer to the Building Division that all associated monopoles and towers in excess of thirty (30) feet in height will withstand sustained winds as required by the Uniform Building Code. 4. No advertisements or displays shall be permitted on the Facility. 5. The placement of any antenna or structure shall not adversely affect any on-site sewage disposal system or its replacement area without written approval from the Division of Environmental Health. 6. The installation of the Facility shall not violate any existing deed restrictions. 7. The Facility shall have a twelve (12) foot wide all-weather access to a publicly maintained road capable of supporting a forty thousand (40,000) pound fire apparatus with fifteen (15) feet of vertical clearance. 8. There shall be no outdoor vehicle or equipment storage except for emergency purposes. 9. The Facility shall fall within current standards and regulations of the FAA, the FCC, and any other State and/or Federal agency with the authority to regulate such Facility. If such standards and regulations are changed, the property owner or responsible party shall bring the Facility into compliance with such revised standards and regulations within ninety (90) days of the effective date of such standards and regulations, unless a more stringent compliance schedule is mandated by the controlling agency. 10. The Facility or combination of the Facilities on the site shall not generate, at any time, electromagnetic frequency radiation (EMF) or radio frequency radiation (RF) in excess of the FCC adopted standards for human exposure, as amended over time. 11. If it is found that the Facility is or will be detrimental to the health, safety, or welfare of persons working or residing near such facility, then the service provider(s) and property owner shall be jointly and solely responsible for the removal, adjustment, or replacement of the Facility. In no case shall the Facility remain in operation if it is found to create a hazard to health, safety, and welfare. The Facility shall not be found to create a hazard to health, safety, or welfare as a result of EMF or RF emissions from the Facility so long as it meets all current standards established by the FCC, pursuant to FCC OET 65. 12. Prior to issuance of the Use Permit, the applicant shall post a performance security in an amount and form determined by the Director of Development Services that is sufficient to cover the cost of a one-time test by a radio frequency consultant selected by the County, sufficient to determine whether the Facility's RF/EMF emissions comply with FCC standards. If the Facility's emissions are determined to exceed FCC standards, the 5 applicant is required to pay for such other tests and other corrective measures as are necessary to establish compliance with FCC OET 65 and its successors and such noncompliance shall constitute sufficient grounds to commence a permit revocation hearing which may lead to permit revocation. The applicant shall cooperate in all respects with the County's consultant to assist the consultant to reach his/her conclusion. 13. All Facilities that are not in continual use for a period of six (6) months shall be considered abandoned. Abandoned Facilities are hereby designated as unlawful and as public nuisances, requiring no amortization period. 14. The Facility may not encroach into, under, over, above, or upon any public street in the unincorporated area of the County in the absence of a valid encroachment permit from the County. 15. The owner/operator of the Facility shall annually submit a written verification, attested to under penalty of perjury, signed by both the owner/operator and an FCC licensee in the employ of or retained by the owner/operator, that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by the facility conforms to safety standards set forth in FCC OET 65. The reports prepared for the Facility shall conform to reporting requirements set by the FCC and the County. The reports shall be submitted to the Planning Division no later than January 31 of each year. 16. The Facility shall be secured at all times to prevent access by the public. 17. The collocation of the antennas allowed by this Use Permit requires the issuance of a building permit from the Butte County Building Division. The Building Division, based upon engineered calculations submitted by the applicant, may determine that the lattice tower cannot physically support the requested number of antennas. If that is the case, the number of new antennas allowed on the tower may be less than the number of antennas permitted by this Use Permit. California Department of Forestry/Butte County Fire 18. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 pound fire apparatus to within 150 feet of all structures. Environmental Health Division 19. Prior to issuance of a building permit, provide a completed Hazardous Materials Release Response Plan to Butte County Environmental Health as required by Chapter 6.95 of the California Health & Safety Code. Pacific Gas and.Electric 20. Any relocation or rearrangement of any existing PG&E facilities in the area to accommodate this project will be at the expense of the developer. 21. There shall be no building of structures, or the storage of materials allowed over or under any existing PG&E facilities, or inside any easements that exist which would infringe on PG&E easement rights. County Counsel C" 0 22. If this entire matter or any finding, action or condition of this matter is appealed to the Board of Supervisors, the applicant or any other developer/operator other than the applicant agrees to indemnify the County of Butte from liability or loss related to the approval of this project and agrees to sign an indemnification agreement in a form approved by County Counsel before the Board's appeal hearing. If the application is not appealed, this condition is deemed satisfied. NOTE: Issuance of this Use Permit does not waive requirement of obtaining Building and Health Division permits before starting construction, nor does it waive any other requirements. Butte County Planning Commission Chairman cc: Land Development Division Building Division Environmental Health Division Butte County Fire Department/CDF Assessors Office Owner z:\up\clearwire Ile up 07-06\planning conunission documents\clearwire Ile - up06-0022 - agenda report draft.doc 7 COUNTY OF BUTTE • FIELD • NUMBER � OROVILLE, CALIFORNIA PURCHASE ORDER F 07-172 S Chico Enterprise Record U Attn: Donna P P.O. Box 9 P Chico, CA 95927 L I E R Issued By DDS/Planning Division Department �a �7 X06 DATE QNTY INVOICE NUMBER AND DESCRIPTION AMOUNT CHARGE TO W.O. # 11/9/06 AMOUNT NOTICE OF PUBLIC HEARING 00.70 40-001-53 2 To be published in the Chico Enterprise Record 3 Thursday, November 16, 2006 4 Please furnish this office two copies of the affidavit of 5 Publication. 6 (Clearwire, LLC, UP06-0022' r/ Butte County Planning Lynn - 538-7602 7 County Center Drive U l e y Oroville, CA 95965 1 Account #016410 I TOTALI 110' 9C2 ITOTALI � 10- 9C2 I I, the undersigned, hereby certify that, to the best of my knowledge, the services or articles specified above have been performed or delivered or, where authorized, are hereby contracted for and that there is a Budget Appropriation for the same. F 07-172 Date: 110*0 y1-GiQ9&",C e men ea or u onze epu SUPPLIER NO. Submit WHITE, CANARY and PINK to PURCHASING SERVICES with supplier's invoice. Retain GOLDENROD DEPT ACCOUNT NO. PROJECT NO. INVOICE NO. INV. DATE ENCUMBRANCE AMOUNT 1 2 3 4 5 6 Submit WHITE, CANARY and PINK to PURCHASING SERVICES with supplier's invoice. Retain GOLDENROD BUTTE COUNTY PLANNING COMMISSION NOTICE OF A PUBLIC HEARING Notice is hereby given by the Butte County Planning Commission that a public hearing is published for Thursday, November 30, 2006, in the Butte County Board of Supervisors' Room, County Administration Center, 25 County Center Drive, Oroville, California, regarding the following item: ITEM DETERMINED TO BE CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW Name: Clearwire,LLC Project: Use Permit, UP06-0022 Planner: Chris Tolley APN: 042-070-197 Zoning: A-5 Location: 1110 WestEast Avenue (on the north side of West East Avenue, 0.25 miles northeast of the Highway 32, West East Avenue intersection), on the west side of the City of Chico. Proposal: Use Permit to collocate four panel antennas at a height of 113 feet on an existing 130 - foot communications tower and the installation of ground equipment including radio cabinets and a Global Positioning System antenna within the existing compound. The above mentioned application is on file and available for public viewing at the office of the Butte County Development Services Department, Planning Division, 7 County Center Drive, Oroville, California. For information call: Chris Tolley, (530) 538-7603, (Monday through Friday, 7:30 a.m. to 4:30 p.m.) Comments maybe submitted in writing at anytime prior to the hearing or orally at the meeting listed above or as may be continued to a later date. Upon action taken by the Planning Commission on the project an appeal may be filed with the Clerk of the Board of Supervisors. The appeal period is 10 days. If you challenge the above application in court, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice or in written correspondence delivered to the Planning Commission, at or prior to, the public hearing. BUTTE COUNTY PLANNING COMMISSION TIM SNELLINGS, DIRECTOR OF DEVELOPMENT SERVICES ADVERTISING INVOICE STATEMENT CHICO ENTERPRISE RECORD 400 EAST PARK AVE. (P.O. BOX 9) CHICO, CA 95927 530-891-1234 ACCOUNT: 016410 November 17, 2006 B.C. DEPT OF DEV 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 NOTICE OF PUBLIC HEARING P.O. # F07-172 PUB: NOVEMBER 16, 2006 111/4 " @ 9.68 / IN INTERNET 108.90 2.00 TOTAL DUE: 110.90 (SPACE FOR FILING STAMP ONLY) IN THE SUPERIOR COURT OF THE STATE OF CALIFORNIA, IN AND FOR THE COUNTY OF BUTTE In The Matter Of NOTICE OF A PUBLIC HEARING-UP06-022 NO: AFFIDAVIT OF PUBLICATION State of California SS. County of Butte The undersigned resident of the county of Butte, State of California, says: That I am, and at all time herein mentioned Was a citizen of the United States and not a party To nor interested in the above entitled matter; That I am the principal clerk of the printer and Publisher of The Chico Enterprise -Record The Oroville Mercury -Register That said newspaper is one of general circula- Tion as.defined by Section 6000 Government Code of the State of California, Case No. 26796 By the Superior Court of the State of California, In and for the County of Butte; that said newspa- Per at all times herein mentioned was printed And published daily in the City of Chico and County of Butte; that the notice of which the Annexed is a true printed copy, was published in Said newspaper on the following days NOVEMBER 16, 2006. Dated November 16. 2006. 4t Chico, Califor (Signature) 1, -, • BUTT E UUUN I Y PLANNING UUMN11b +VPI . . . NOTICE OF A PUBLIC HEARING l 4otice is herebygiven by the Butte County Planning Commission that a public nearing is published for Thursday, November 30, 2006, in the Butte County Board of Supervisors' Room, County Administration Center, 25 County Center Drive, Oroville, California, regarding the following item : ITEM DETERMINED TO BE CATEGORICALL, EXEMPT' FROM . ENVIRONMENTAL REVIEW, Name: Clearwire, LLC + -•-Project: Use Permit UP06-0022 Planner: Chris Tolley . 1 APN: 042-070-197 Zoning: A-5 Location: 1110 West East'AVenue (on tKe'north side of West East Avenue,' 0.25 miles northeast of the Highway 32,%West East Avenue intersection), on the west side of the City of Chico. . Proposal: Use. Permit to collocate four panel antennas ata height of 113 feet on an existing,130-foot communications tower and installation of ground equipment including radio cabinets and a Glbbal.Positioning System antenna within the existing compound.', The above mentioned application is on file and available for -public viewing at the office of the Butte County Development Services Department, Planning 'divisions, 7 Countg.,Center Drive, Oroville'California. For information call : Chris Tolley, (530) 538-7603, (Monday through Friday, 7:30 a.m: tof4:30 p.m.) Comments maybe submitted in writing at any time prior to the hearing or oral- �ly at the meeting listed above or as may be continued to a later ate. Upon action.taken by the Planning Commission on the project an appeal may be filed with the Clerk of the Board of Supervisors the Appeal period is 10 days. ay It you challenge the -above application in court;!you mbe limited to raising, only those issues you'or someone else -raised at the public hearing described in this notice or in written correspondence delivered to the Planning Commis- sion, at or prior to; the public hearing." , BUTTE COUNTY PLANNING COMMISSION TIM SNELLINGS, DIRECTOR OF. DEVELOPMENT SERVICES P0: F07-172 Pablish' 11 /16/2006 R ti No. .................................. In the Matter of Affidavit of Publication --of-- B-02 a RESOLUTION NO. PC 06-65 A RESOLUTION OF THE BUTTE COUNTY PLANNING COMMISSION APPROVING USE PERMIT 06-0022 WHEREAS, the Planning Commission has considered Use Permit 06-0022 for Clearwire, LLC, in accordance with Chapter 24, Section 45; Use Permits, of the Butte County Code on Assessor's Parcel Number 042-070-197; and WHEREAS, the Planning Commission has determined that project is categorically exempt under Section 15311 in accordance with the California Environmental Quality Act; and WHEREAS, said Use Permit was referred to various affected public and private agencies, County departments, and referral agencies for review and comments; and WHEREAS, the Use Permit was considered. at a duly noticed public hearing held on November 30, 2006; and WHEREAS, the Planning Commission has considered a report from the Planning Division and public comments. NOW, THEREFORE, BE IT RESOLVED, that the Planning Commission: I. Finds that this project is exempt from the provisions of the California Environmental Quality Act under Section 15311. Section 15311 consists of construction of minor structures accessory (appurtenant) to existing facilities. Antennas placed on an existing communications lattice tower are considered to be accessory structures. A. Because the project is exempt from the provisions of CEQA, the payment of fees pursuant to Fish and Game Code Section 711.4 and 14 CCR 753.5 is not required. B. The custodian of the record is the Department of Development Services. The location of the record is 7 County Center Drive, Oroville CA 95965. II. Makes the following Use Permit findings: A. The proposed location, size, design, and operating characteristics of the proposed use are in accordance with the purpose of this Ordinance, the purpose of the zone in which the site is located, the Butte County General Plan, and the development policies and standards of the County because: Conditions of approval have been applied to this project pursuant to the applicable requirements of Zoning Code Section 24-262 (Wireless Communication Facilities). The project is in accordance with the purpose of the A-5 Zone and the Butte County General Plan land use designation Orchard and Field Crops, in -which the land lies. The Orchard and Field Crops land use designation allows public utilities as Secondary Uses. The A- 5 zone allows collocations with approval of a Use Permit when the facilities that fall within 1, 000feet of the zones identified in the "Permit Requirements " table located in section 24-262(d). 1 B. The location, size, design, and operating characteristics of the proposed use would be compatible with, and would not adversely affect, or be detrimental to adjacent uses, residents, buildings, structures, or natural resources, with consideration given to: 1. Harmony in scale, bulk, coverage, and density: The proposed antennas and microwave dishes would not increase the height of the existing communications lattice tower or extend horizontally beyond the existing vertical plane. 2. The availability of public facilities, services and utilities: Electrical power service is already established to the property and no additional services or utilities are required. A water source and a sewage disposal system are not required. 3. The harmful effect, if any, upon desirable neighborhood character: The project site is already developed with a 130 foot tall communications lattice tower and accessory ground mounted equipment cabinets and shelters. The radio-frequency emissions from the existing and proposed antennas and microwave dishes would meet FCC standards for public exposure. The proposed antennas would not result in a significant visual impact to the neighborhood in that the new antennas and mounting hardware would be painted to match the color of the existing tower. 4. The generation of traffic and the capacity and physical character of surrounding streets: Only a minor amount of vehicle traffic would be generated during installation of the antennas, microwave dishes and equipment cabinet. The project would result in approximately one to two site visits per month by maintenance personnel. West East Avenue, which would provide access for the project site, would not be impacted by this increase in vehicular traffic. 5. The suitability of the site for the type and intensity of use or development which is proposed: The site is ideally suited for the project because the proposed antennas and microwave dishes would be mounted on an existing communications lattice tower. 6. Any other relevant impact of the proposed use: The Planning Division has circulated the proposed communication facility application to County Agencies and has received no evidence that the use would cause any other relevant impact. C. Based on the above findings, the proposed location, size, design, and operating characteristics of the proposed use and the conditions under which it would be operated or maintained would not be detrimental to the public health, safety or welfare, or injurious to properties or improvements in the vicinity. 0) D. The proposed use will comply with each of the applicable provisions of Butte County Code Chapter 24, Section 262. E. This project would place antennas on an existing communications lattice tower, which eliminates the need for a new communications tower/monopole to be erected elsewhere in the project area. F. The radio-frequency emissions generated by the antennas on the communications lattice tower would be below the public exposure limits set by the Federal Communications Commission for wireless communication facilities. G. The proposed antennas and microwave dishes would not create any impacts to aircraft operations because they will not increase the height of the existing communications lattice tower nor extend horizontally beyond the existing antennas. H. Wireless telephone services are regulated by the California Public Utilities Commission and are considered to be a public use. III. Approves Use Permit 06-0022 for Clearwire, LLC, subject to the conditions as set forth in the attachment Exhibit A to the resolution. DULY PASSED AND ADOPTED this 30th Day of November, 2006, the following vote: AYES: Commissioners Marin, Leland, Lambert, Wilson, and Chairman Nelson NOES: No one ABSENT: No one ABSTAIN: No one CHUCK NELSON, Chairman Planning Commission County of Butte, State of California ATTEST: LYft RICHARDSON, Secretary Planning Commission County of Butte, State of California 3 e ^s EXHIBIT A USE PERMIT BUTTE COUNTY PLANNING COMMISSION DATE: (Certified Mail Rec.) UP06-0022 PERMIT NO. 042-070-197 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Clearwire, LLC is hereby granted a Use Permit in accordance with application filed to collocate four pannel antennas and four microwave dishes at a height of 113 - feet within 1,000 feet of designated residential zones. Approval is also granted for the associated ground equipment and Global Positioning System antenna. The project site is zoned A-5 and is designated as Orchard and Field Crops by the Butte County General Plan. 1. Failure to comply with the conditions specified herein as the basis for approval of application and issuance of permit constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Sec. 24-45. 2. Unless otherwise provided for in a special condition to this Use Permit, all conditions must be completed prior to or concurrently with the establishment of the granted use. The use granted by this permit must be established within 24 months of the delivery of the countersigned permit to the Permittee. 3. Minor changes may be approved administratively by the Directors of Development Services, Environmental Health, or Public Works upon receipt of a substantiated written request by the applicant, or their respective designee. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. 4. If any use for which a Use Permit has been granted is not established within two years of the date of receipt of the countersigned permit by the Permittee, the permit shall become null and void and reapplication and a new permit shall be required to establish the use. 5. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Permittee. 4 Conditions of Approval: Planning Division 1. The project site shall be developed in accordance with the approved project site plan and the conditions contained herein. Said site plan is on file in the Planning Division, is identified as "Attachment D" and date-stamped September 7, 2006, and is incorporated herein by this reference. 2. The new antennas, microwave dishes and mounting hardware shall be painted to match the color scheme of the existing tower. 3. The installation of the Facility shall comply with all applicable building and electrical codes. The Facility operator shall submit certification from a registered structural engineer to the Building Division that all associated monopoles and towers in excess of thirty (30) feet in height will withstand sustained winds as required by the Uniform Building Code. 4. No advertisements or displays shall be permitted on the Facility. 5. The placement of any antenna or structure shall not adversely affect any on-site sewage disposal system or its replacement area without written approval from the Division of Environmental Health. 6. The installation of the Facility shall not violate any existing deed restrictions. 7. The Facility shall have a twelve (12) foot wide all-weather access to a publicly maintained road capable of supporting a forty thousand (40,000) pound fire apparatus with fifteen (15) feet of vertical clearance. 8. There shall be no outdoor vehicle or equipment storage except for emergency purposes. 9. The Facility shall fall within current standards and regulations of the FAA, the FCC, and any other State and/or Federal agency with the authority to regulate such Facility. If such standards and regulations are changed, the property owner or responsible party shall bring the Facility into compliance with such revised standards and regulations within ninety (90) days of the effective date of such standards and regulations, unless a more stringent compliance schedule is mandated by the controlling agency. 10. The Facility or combination of the Facilities on the site shall not generate, at any time, electromagnetic frequency radiation (EMF) or radio frequency radiation (RF) in excess of the FCC adopted standards for human exposure, as amended over time. 11. If it is found that the Facility is or will be detrimental to the health, safety, or welfare of persons working or residing near such facility, then the service provider(s) and property owner shall be jointly and solely responsible for the removal, adjustment, or replacement of the Facility. In no case shall the Facility remain in operation if it is found to create a hazard to health, safety, and welfare. The Facility shall not be found to create a hazard to health, safety, or welfare as a result of EMF or RF emissions from the Facility so long as it meets all current standards established by the FCC, pursuant to FCC OET 65. 12. Prior to issuance of the Use Permit, the applicant shall post a performance security in an amount and form determined by the Director of Development Services that is sufficient to cover the cost of a one-time test by a radio frequency consultant selected by the County, sufficient to determine whether the Facility's RF/EMF emissions comply with FCC standards. If the Facility's emissions are determined to exceed FCC standards, the 5 applicant is required to pay for such other tests and other corrective measures as are necessary to establish compliance with FCC OET 65 and its successors and such noncompliance shall constitute sufficient grounds to commence a permit revocation hearing which may lead to permit revocation. The applicant shall cooperate in all respects with the County's consultant to assist the consultant to reach his/her conclusion. 13. All Facilities that are not in continual use for a period of six (6) months shall be considered abandoned. Abandoned Facilities are hereby designated as unlawful and as public nuisances, requiring no amortization period. 14. The Facility may not encroach into, under, over, above, or upon any public street in the unincorporated area of the County in the absence of a valid encroachment permit from the County. 15. The owner/operator of the Facility shall annually submit a written verification, attested to under penalty of perjury, signed by both the owner/operator and an FCC licensee in the employ of or retained by the owner/operator, that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by the facility conforms to safety standards set forth in FCC OET 65. The reports prepared for the Facility shall conform to reporting requirements set by the FCC and the County. The reports shall be submitted to the Planning Division no later than January 31 of each year. 16. The Facility shall be secured at all times to prevent access by the public. 17. The collocation of the antennas allowed by this Use Permit requires the issuance of a building permit from the Butte County Building Division. The Building Division, based upon engineered calculations submitted by the applicant, may determine that the lattice tower cannot physically support the requested number of antennas. If that is the case, the number of new antennas allowed on the tower may be less than the number of antennas permitted by this Use Permit. California Department of Forestry/Butte County Fire 18. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 pound fire apparatus to within 150 feet of all structures. Environmental Health Division 19. Prior to issuance of a building permit, provide a completed Hazardous Materials Release Response Plan to Butte County Environmental Health as required by Chapter 6.95 of the California Health & Safety Code. Pacific Gas and.Electric 20. Any relocation or rearrangement of any existing PG&E facilities in the area to accommodate this project will be at the expense of the developer. 21. There shall be no building of structures, or the storage of materials allowed over or under any existing PG&E facilities, or inside any easements that exist which would infringe on PG&E easement rights. County Counsel Co I S JP 22. If this entire matter or any finding, action or condition of this matter is appealed to the Board of Supervisors, the applicant or any other developer/operator other than the applicant agrees to indemnify the County of Butte from liability or loss related to the approval of this project and agrees to sign an indemnification agreement in a form approved by County Counsel before the Board's appeal hearing. If the application is not appealed, this condition is deemed satisfied. NOTE: Issuance of this Use Permit does not waive requirement of obtaining Building and Health Division permits before starting construction, nor does it waive any other requirements. r B e County Planning Commission Chairman cc: Land Development Division Building Division Environmental Health Division Butte County Fire Department/CDF Assessors Office Owner z:\up\clearwire llc up 07-06\planning commission documents\clearwire 11c - up06-0022 - agenda report draft.doc 7 USE PERMIT 'SEC 2 0 2006 BUTTE COUNTY PLANNING COMMISSION DATE: (Certified Mail Rec.) UP06-0022 PERMIT NO. 042-070-197 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Clearwire, LLC is hereby granted a Use Permit in accordance with application filed to collocate four pannel antennas and four microwave dishes at a height of 113 - feet within 1,000 feet of designated residential zones. Approval is also granted for the associated ground equipment and Global Positioning System antenna. The project site is zoned A-5 and is designated as Orchard and Field Crops by the Butte County General Plan. 1. Failure to comply with the conditions specified herein as the basis for approval of application and issuance of permit constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Sec. 24-45. 2. Unless otherwise provided for in a special condition to this Use Permit, all conditions must be completed prior to or concurrently with the establishment of the granted use. The use granted by this permit must be established within 24 months of the delivery of the countersigned permit to the Permittee. 3. Minor changes may be approved administratively by the Directors of Development Services, Environmental Health, or Public Works upon receipt of a substantiated written request by the applicant, or their respective designee. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. 4. If any use for which a Use Permit has been granted is not established within two years of the date of receipt of the countersigned permit by the Permittee, the permit shall become null and void and reapplication and a new permit shall be required to establish the use. 5. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Permittee. 1 Conditions of Approval: Planning Division The project site shall be developed in accordance with the approved project site plan and the conditions contained herein. Said site plan is on file in 'the Planning Division, is identified as "Attachment D" and date-stamped September 7, 2006, and is incorporated herein by this reference. 2. The new antennas, microwave dishes and mounting hardware shall be painted to match the color scheme of the existing tower. 3. The installation of the Facility shall comply with all applicable building and electrical codes. The Facility operator shall submit certification from a registered structural engineer to the Building Division that all associated monopoles and towers in excess of thirty (30) feet in height will withstand sustained winds as required by the Uniform Building Code. 4. No advertisements or displays shall be permitted on the Facility. . 5. The placement of any antenna or structure shall not adversely affect any on-site sewage disposal system or its replacement area without written approval from the Division of Environmental Health. 6. The installation of the Facility shall not violate any existing deed restrictions. 7. The Facility shall have a twelve (12) foot wide all-weather access to a publicly maintained road capable of supporting a forty thousand (40,000) pound fire apparatus with fifteen (15) feet of vertical clearance. 8. There shall be no outdoor vehicle or equipment storage except for emergency purposes. 9. The Facility shall fall within current standards and regulations of the FAA, the FCC, and any other State and/or Federal agency with the authority to regulate such Facility. If such standards and regulations are changed, the property owner or responsible party shall bring the Facility into compliance with such revised standards and regulations within ninety (90) days of the effective date of such standards and regulations, unless a more stringent compliance schedule is mandated by the controlling agency. 10. The Facility or combination of the Facilities -on the site shall not generate, at any time, electromagnetic frequency radiation (EMF) or radio frequency radiation (RF) in excess of the FCC adopted standards for human exposure, as amended over time. 1.1. If it is found that the Facility is or will be detrimental to the health, safety, or welfare of persons working or residing near such facility, then the service provider(s) and property owner shall be jointly and solely responsible for the removal, adjustment, or replacement of the Facility. In no case shall the Facility remain in operation if it is found to create a hazard to health, safety, and welfare. The Facility shall not be found to create a hazard to health, safety, or welfare as a result of EMF or RF emissions from the Facility so long as it -meets all current standards established by the FCC, pursuant to FCC OET 65. 12. Prior to issuance of the Use Permit, the applicant shall post a performance security in an amount and form determined by the Director of Development Services that is sufficient to cover the cost of a one-time test by a radio frequency consultant selected by the County, sufficient to determine whether the Facility's RF/EMF emissions comply with FCC standards. If the Facility's emissions are determined to exceed FCC standards, the i 2 applicant is required to pay for such other tests and other corrective measures as are necessary to establish compliance with FCC OET 65 and its successors and such noncompliance shall constitute sufficient grounds to commence a permit revocation hearing which may lead to permit revocation. The applicant shall cooperate in all respects with the County's consultant to assist the consultant to reach his/her conclusion. 13. All Facilities that are not in continual use for a period of six (6) months shall be considered abandoned. Abandoned Facilities are hereby designated as unlawful and as public nuisances, requiring no amortization period. 14. The Facility may not encroach into, under, over, above, or upon any public street in the unincorporated area of the County in the absence of a valid encroachment permit from the County. 15. The owner/operator of the Facility shall annually submit a written verification, attested to under penalty of perjury, signed by both the owner/operator and an FCC licensee in the employ of or retained by the owner/operator, that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by the facility conforms to safety standards set forth in FCC OET 65. The reports prepared for the Facility shall conform to reporting requirements set by the FCC and the County. The reports shall be submitted to the Planning Division no later than January 31 of each year. 16. The Facility shall be secured at all times to prevent access by the public. 17. The collocation of the antennas allowed by this Use Permit requires the issuance of a building permit from the Butte County Building Division. The Building Division, based upon engineered calculations submitted by the applicant, may determine that the lattice tower cannot physically support the requested number of antennas. If that is the case, the number of new antennas allowed on the tower may be less than the number of antennas permitted by this Use Permit. California Department of Forestry/Butte County Fire 18. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 pound fire apparatus to within 150 feet of all structures. Environmental Health Division 19. Prior to issuance of a building permit, provide a completed Hazardous Materials Release Response Plan to Butte County Environmental Health as required by Chapter 6.95 of the California Health & Safety Code. Pacific Gas and Electric 20. Any relocation or rearrangement of any existing PG&E facilities in the area to accommodate this project will be at the expense of the developer. 21. There shall be no building of structures, or the storage of materials allowed over or under any existing PG&E facilities, or inside any easements that exist which would infringe on PG&E easement rights. County Counsel 3 22. If this entire matter or any finding, action or condition of this matter is appealed to the Board of Supervisors, 'the applicant or any other developer/operator other than the applicant agrees to indemnify the County of Butte from liability or loss related to the approval of this project and agrees to sign an indemnification agreement in a form approved by County Counsel before the Board's appeal hearing. If the application is not appealed, this condition is deemed satisfied. I hereby declare under penalty of perjury that I have read the foregoing conditions, that they are in fact the conditions which were imposed upon the granting of this use permit, and that I agree to abide fully by said conditions. c Date: �e«�-6� %� Applicant NOTE: Issuance of this Use Permit does not waive requirement of obtaining Building and Health Division permits before starting uction, nor does it waive any other requirements. Butte County Planning Commission Chairman cc: Land Development Division Building Division Environmental Health Division Butte County Fire Department/CDF Assessors Office Owner z:\up\clearwire llc up 07-06\planning commission documents\clearwire llc - up06-0022 - agenda report draft.doc al Butte County Department ofDevelopment Services Tim Snellings, Director www.buttecounty.net/dds 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile ADMINISTRATION * BUILDING * PLANNING December 19, 2006 Clearwire LLC 381 South Lexington Dr. Suite 103 Folsom, CA 95630 Re: Use PermitUP06-0022, APN 042-070-197 Dear Clearwire LLC: Enclosed is your validated Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Should you have any questions regarding this matter, please contact this office between 7:30 a.m. and 4:30 p.m., Monday through Friday. Sincerely, Tina Bonham Office Specialist, Senior enc. cc: Land Development Division (g) Building Division (y) Environmental Health (p) Department of Forestry (gld) G.I.S. (w) Owner (w) U.S. Postal Service,,, ru m CERTIFIED MAILT. RECEIPT Ln (Domestic Mail Only; Er c OFF'-CIAL.: usU7 Postage pCertltled Fee ,• ,r ED \� C3 Retum Receipt Fee t Postmark (Endorsement Required) Here Restricted Delivery Feeru (Eco ndorsement Required) r F r°'a;Clearwire,LLC Ln - - E3 sent 381 South Lexington -Dr. Suite 103 C3 , r�VBr Folsom, CA 95630 - --. or PO ----- - — - cftyl 1 . :11 JLme 2002 "�v TO: FROM: SUBJECT: DATE: 9 0. Butte County Department ofDevelopment Services Tim Snellings, Director www.buttecounty.net/dds 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile Butte County Assessor's Office Butte County Planning Department Clearwire LLC, UP06-0022 December 19, 2006 Pursuant to Section 65863.5 of the Government Code, the following parcel identified as 042-070-197, was: Rezoned from Granted a variance to to zoning district. X Issued a conditional Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound, A-5,. t .. Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile ADMINISTRATION * BUILDING * PLANNING 11/30/2006 Clearwire LLC 381 South Lexington Dr. Suite 103 Folsom, CA 95630 Re: Use Permit, UP 07-06, AP: 042-070-197 Gentlemen: At the regular meeting of the Butte County Planning Commission held November 30, 2006, your request for a Use PermitUse Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound, on property zoned, A-5, (Agricultural, 5 -acre parcels), was approved subject to the conditions listed on the enclosures. The property is located on the north side of West East Ave., 1300' (0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) Please sign both copies and return both copies to this Division within 40 calendar days. Should you desire to appeal any of the conditions imposed by the Planning Commission, you must do so in writing prior to 5:00 p.m., Monday, December 11, 2006 to the: Clerk of the Board of Supervisors 25 County Center Drive Oroville, California, 95965 The appeal fee of $50.00 must be paid at that time. If you do not appeal, and if there are no other appeals within the 10 calendar -day appeal period, the action of the Planning Commission is final. APPROVAL OF PROJECT SUBJECT TO PAYMENT OF ALL APPLICABLE FEES Payment of all applicable fees will be required as a condition of approval for your project. Prompt payment of invoiced amounts will expedite the approval process in satisfying this condition. Please be aware that failure to return the signed copies within 40 calendar days will invalidate the Planning Commission's approval. Re-application to this Division would then be necessary. 4 0 The Use Permit is deemed granted when the enclosures have been signed by the applicant, with the counter signature of the Chairman of the Planning Commission, and said permit is received by the applicant by registered mail. Pursuant to Section 66020 (d) (2) of the Government Code you are hereby notified that you have 90 days to register a protest challenging any fees, dedications, reservations, or exactions imposed as conditions of approval for this project. Should you have any questions regarding this matter, please contact Chris Tolley at 538-7603 between 8:00 a.m. and 4:00 p.m., Monday through Friday. Sincerely, LynnicR hardson Commission Clerk Cc: Epic Wireless/ David Wiltsee Leland Stanford Masonic Temple Association kAIetters\merge letters\APPRCATUP.dot COi7MV ' NOV 2.0 2003 BUTTE COUNTY PLANNING COMMISSION DEVELOPAMNT NOTICE OF A PUBLIC HEARING SERVICES Notice is hereby given by the Butte County Planning Commission that a public hearing is published for Thursday, November 30, 2006, in the Butte County Board of Supervisors' Room, County Administration Center, 25 County Center Drive, Oroville, California, regarding the following item: ITEM DETERMINED TO BE CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW Name: Clearwire,LLC Project: Use Permit, UP06-0022 Planner: Chris Tolley APN: 042-070-197 Zoning: A-5 Location: 1110 WestEast Avenue (on the north side of West East Avenue, 0.25 miles northeast of the Highway 32, West East Avenue intersection), on the west side of the City of Chico. Proposal: Use Permit to collocate four panel antennas at a height of 113 feet on an existing 130 - foot communications tower and the installation of ground equipment including radio cabinets and a Global Positioning System antenna within the existing compound. The above mentioned application is on file and available for public viewing at the office of the Butte County Development Services Department, Planning Division, 7 County Center Drive, Oroville, California. For information call: Chris Tolley, (530) 538-7603, (Monday through Friday, 7:30 a.m. to 4:30 p.m.) Comments maybe submitted in writing at anytime prior to the hearing or orally at the meeting listed above or as may be continued to a later date. Upon action taken by the Planning Commission on the project an appeal may be filed with the Clerk of the Board of Supervisors. The appeal period is 10 days. If you challenge the above application in court, you may be limited to raising only those issues you or someone else'raised at the public hearing described in this notice or in written correspondence delivered to the Planning Commission, at or prior to, the public hearing. BUTTE COUNTY PLANNING COMMISSION TIM SNELLINGS, DIRECTOR OF DEVELOPMENT SERVICES To be published in the Chico Enterprise Record, Thursday, November 16, 2006. Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile ADMINISTRATION * BUILDING * PLANNING November 16, 2006 Clearwire LLC 381 South Lexington Dr. Suite 103 Folsom, CA 95630 Re: UP 07-06, AP: 042-070-197 Gentlemen: Enclosed is a copy of the Agenda Report concerning your application for a Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound on property zoned A-5 (Agricultural, 5 -acre parcels). The project is located on the north side of West East Ave., 1300'(0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (I 110 West East Ave., Chico). Should you have any concerns with the report or conditions of approval, please contact us in advance of the meeting so that we may work together to resolve your concerns. A public hearing has been set for November 30, 2006, at 9:00 a.m. This meeting will be held in the Board of Supervisors' Room, 25 County Center Drive, Oroville, California. The Planning Commission recommends that the applicant or their authorized representative be present at the hearing to respond to any questions the Commission may have. Should you have any questions regarding this matter, please contact Chris Tolley of this office at 538-7603, between 8:00 a.m. and 4:00 p.m., Monday through Friday. Sincerely, Lynn Richardson Commission Clerk Enc. cc: Leland Stanford Masonic Temple Association Environmental Health Land Development K:\letters\merge letterASCHEDULE.dot • BUTTE COUNTY PLANNING COMMISSION AGENDA REPORT — November 30, 2006 Applicant: Clearwire, LLC Supervisor 2 District: Owner: Leland Stanford Masonic Temple Association File #: UP06-0022 Planner: Chris Tolley Request: Clearwire, LLC requests a Use Location: 1110 West East Avenue (on Permit to collocate four panel the north side of West East antennas at a height of 113 -feet Avenue, 0.25 miles on an existing 130 -foot northeast of the Highway 32 communications tower and the - West East Avenue installation of ground equipment intersection), on the west including radio cabinets and a side of the City of Chico. Global Positioning System antenna within the existing compound. G.P.: Orchard and Field Crops Attachments: Zoning: A-5 A: Resolution with Exhibit A B: General Plan/Zoning Map Zone Date: October 7, 1975 C: Vicinity Map APN: 042-070-197 D: Site Plan Parcel Size: 5.16 EXECUTIVE SUMMARY: Clearwire, LLC requests a Use Permit to collocate four panel antennas at a height of 113 -feet on an existing 130 -foot communications tower and the installation of ground equipment including radio cabinets and a Global Positioning System antenna within 1,000 feet of designated residential zones. The parcel is located at 1110 West East Avenue (on the north side of West East Avenue, 0.25 miles northeast of the Highway 32 - West East Avenue intersection), on the west side of the City of Chico. Staff recommends approval of this Use Permit with the findings and conditions identified below. PROJECT DESCRIPTION: • Clearwire, LLC requests a Use Permit to collocate four panel antennas at a height of 113 - feet on an existing 130 -foot communications tower and the installation of ground equipment including radio cabinets and a Global Positioning System antenna within the existing compound. ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 1 of 11 ■ • Three antennas are proposed to be installed immediately, and one antenna will be collocated at a later date. • The proposed panel antennas and ground equipment will provide wireless internet service on behalf Clearwire, LLC in Chico and the surrounding areas. Clearwire, LLC is concurrently applying for other facilities in Butte County, the City of Chico, the Town of Paradise, Glenn County and Tehama County. • The proposed panel antennas are 1.74 square feet in total area (36" long by 7" wide). • The associated ground equipment will be placed on a concrete pad, inside the existing fenced compound. • The facility is currently unmanned, and will remain unmanned. Company technicians will visit the site, approximately once a month, to perform routine maintenance. • The existing tower will not be expanded or enlarged, and the proposed antennas will not extend beyond the existing vertical plane. • Access to the site is, and will continue to be, from West East Avenue. • Exterior lighting would only be utilized during maintenance. • No advertising signage is proposed, except the emergency contact information and those required by the FCC. SITE CHARACTERISTICS: • The site is designated A-5 (Agricultural five acre minimum) by the Zoning Code. The General Plan Land Use Designation is Orchard and Field Crops. • The primary use of the site is for the Leland Stanford Masonic Temple. • The existing lattice tower and initial communication facilities were approved by Building Permit number 98-1854. • The existing communication facilities are located at the height of 130 -feet, 123 -feet and 100 -feet. • The existing tower and associated equipment are located within the 2,362.5 square foot leased area. • The parcels northwest, west and southwest of the project site are zoned A-5, and designated Orchard and Field Crops by the Butte County General Plan. The parcels northeast, east and southeast of the project site are zoned AR (Agricultural Residential), R-4 (Residential) and S -R (Suburban Residential), and are designated Low Density Residential by the Butte County General Plan. Zoning/General Plan Consistency • The site is designated Orchard and Field Crops by the Butte County General Plan, which allows public uses as secondary uses. Wireless communications providers are considered a public utility because they are regulated by the California Public Utilities Commission. ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 2 of 11 ■ i • Section 24-91 of the Butte County Code states that communications facilities, including the collocation of antennas on towers/poles, are not permitted in the A-5 (General Commercial) zone unless a permit is obtained, subject to the requirements of Butte County Code Section 24-262. • Section 24-262(d) states that a Minor Use Permit must be obtained for the collocation of antennas on an existing tower in the A-5 (General Commercial) Zone; however, a Use Permit is required for facilities that fall within 1,000 -feet of the zones identified in "Permit Requirements" table located in section 24-262(d), including the R-4 and SR zones. Since the project site is located adjacent to the R-4 and SR zoned properties, a Use Permit is required. ANALYSIS: • The proposed antennas are not expected to create any significant visual impacts because they would not increase the height of the existing tower, nor will they extend beyond the existing vertical plane. • The site plan identifying the tower's elevation and proposed antennas show that they would not significantly change the appearance of the tower. • The antennas and mounting hardware are proposed to be painted to match the existing tower. • Only a minor amount of construction activity would be required to install the proposed antennas and associated ground equipment. • The project would not result in a significant increase in air emissions, fugitive dust emissions, light, noise, or vehicle traffic. • The new communication facilities will utilize a battery as back-up power. Radio -Frequency Emissions • A radio-frequency analysis, prepared by a registered electrical engineer, determined that the emissions from the existing and proposed antennas would be 0.211 % of the FCC standard for public exposure to radio-frequency (RF) emissions. • The proposed operation of the site would be in compliance with the FCC requirements for public exposure to RF radiation. Conditions of Approval The project has been conditioned to meet the requirements of Section 24-262, including: • Radio-frequency emissions in excess of FCC standards are not allowed. • The antennas must be painted to match the color scheme of the existing antennas and tower. • Facilities that are not in continual use for a period of six (6) months shall be considered to be abandoned and must be removed. ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 3 of 11 ■ • Verification must be submitted annually attesting that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by the facility conforms to safety standards set forth in FCC Office of Engineering & Technology Bulletin 65 (Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields, August 1997). • Access to the site must be at least 12 feet wide and capable of supporting a 40,000 -pound fire apparatus. • Submittal of a bond or cash deposit is required to cover the cost of a radio-frequency study and removal of the proposed facilities. • Engineering analysis is required to ensure that the existing lattice tower would be able to support the proposed antennas. ENVIRONMENTAL REVIEW: This application for a Use Permit to allow the collocation of antennas on an existing communications tower is Categorically Exempt from the provisions of the California Environmental Quality Act under Section 15311. Section 15311 consists of construction of minor structures accessory (appurtenant) to existing facilities. Antennas placed on an existing communications lattice tower are considered to be accessory structures. Figure 1 Aerial Photograph ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 4 of 11 ■ 0 • ATTACHEMNT A RESOLUTION - A RESOLUTION OF THE BUTTE COUNTY PLANNING COMMISSION APPROVING USE PERMIT 06-0022 WHEREAS, the Planning Commission has considered Use Permit 06-0022 for Clearwire, LLC, in accordance with Chapter 24, Section 45; Use Permits, of the Butte County Code on Assessor's Parcel Number 042-070-197; and WHEREAS, the Planning Commission has determined that project is categorically exempt under Section 15311 in accordance with the California Environmental Quality Act; and WHEREAS, said Use Permit was referred to various affected public and private agencies, County departments, and referral agencies for review and comments; and WHEREAS, the Use Permit was considered at a duly noticed public hearing held on November 30, 2006; and WHEREAS, the Planning Commission has considered a report from the Planning Division and public comments. NOW, THEREFORE, BE IT RESOLVED, that the Planning Commission: I. Finds that this project is exempt from the provisions of the California Environmental Quality Act under Section 15311. Section 15311 consists of construction of minor structures accessory (appurtenant) to existing facilities. Antennas placed on an existing communications lattice tower are considered to be accessory structures. A. Because the project is exempt from the provisions of CEQA, the payment of fees pursuant to Fish and Game Code Section 711.4 and 14 CCR 753.5 is not required. B. The custodian of the record is the Department of Development Services. The location of the record is 7 County Center Drive, Oroville CA 95965. II. Makes the following Use Permit findings: A. The proposed location, size, design, and operating characteristics of the proposed use are in accordance with the purpose of this Ordinance, the purpose of the zone in which the site is located, the Butte County General Plan, and the development policies and 'standards of the County because: Conditions of approval have been applied to this project pursuant to the applicable requirements of Zoning Code Section 24-262 (Wireless Communication Facilities). The project is in accordance with the purpose of the A-5 Zone and the Butte County General Plan land use designation Orchard and Field Crops, in which the land lies. The Orchard and Field Crops land use designation allows public utilities as Secondary Uses. The A- 5 zone allows collocations with approval of a Use Permit when the facilities ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 5 of 11 ■ • 0 that fall within 1, 000feet of the zones identified in the "Permit Requirements" table located in section 24-262(d). B. The location, size, design, and operating characteristics of the proposed use would be compatible with, and would not adversely affect, or be detrimental to adjacent uses, residents, buildings, structures, or natural resources, with consideration given to: 1. Harmony in scale, bulk, coverage, and density: The proposed antennas would not increase the height of the existing communications lattice tower or extend horizontally beyond the existing vertical plane. 2. The availability of public facilities, services and utilities: Electrical power service is already established to the property and no additional services or utilities are required. A water source and a sewage disposal system are not required. 3. The harmful effect, if any, upon desirable neighborhood character: The project site is already developed with a 130 foot tall communications lattice tower and accessory ground mounted equipment cabinets and shelters. The radio-frequency emissions from the existing and proposed antennas would meet FCC standards for public exposure. The proposed antennas would not result in a significant visual impact to the neighborhood in that the new antennas and mounting hardware would be painted to match the color of the existing tower. 4. The generation of traffic and the capacity and physical character of surrounding streets: Only a minor amount of vehicle traffic would be generated during installation of the antennas and equipment cabinet. The project would result in approximately one to two site visits per month by maintenance personnel. West East Avenue, which would provide access for the project site, would not be impacted by this increase in vehicular traffic. 5. The suitability of the site for the type and intensity of use or development which is proposed: The site is ideally suited for the project because the proposed antennas would be mounted on an existing communications lattice tower. 6. Any other relevant impact of the proposed use: The Planning Division has circulated the proposed communication facility application to County Agencies and has received no evidence that the use would cause any other relevant impact. C. Based on the above findings, the proposed location, size, design, and operating characteristics of the proposed use and the conditions under which it would be operated or maintained would not be detrimental to the public ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 6 of 11 ■ health, safety or welfare, or injurious to properties or improvements in the vicinity. D. The proposed use will comply with each of the applicable provisions of Butte County Code Chapter 24, Section 262. E. This project would place antennas on an existing communications lattice tower, which eliminates the need for a new communications tower/monopole to be erected elsewhere in the project area. F. The radio-frequency emissions generated by the antennas on the communications lattice tower would be below the public exposure limits set by the Federal Communications Commission for wireless communication facilities. G. The proposed antennas would not create any impacts to aircraft operations because they will not increase the height of the existing communications lattice tower nor extend horizontally beyond the existing antennas. H. Wireless telephone services are regulated by the California Public Utilities Commission and are considered to be a public use. III. Approves Use Permit 06-0022 for Clearwire, LLC, subject to the conditions as set forth in the attachment Exhibit A to the resolution. DULY PASSED AND ADOPTED this 30th Day of November, 2006, the following vote: AYES: NOES: ABSENT: ABSTAIN: CHUCK NELSON, Chairman Planning Commission County of Butte, State of California ATTEST: LYNN RICHARDSON, Secretary Planning Commission County of Butte, State of California ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 7 of I I ■ EXHIBIT A USE PERMIT BUTTE COUNTY PLANNING COMMISSION DATE: (Certified Mail Rec.) UP06-0022 PERMIT NO. 042-070-197 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Clearwire, LLC is hereby granted a Use Permit in accordance with application filed to collocate four pannel antennas at a height of 113 -feet within 1,000 feet of designated residential zones. Approval is also granted for the associated ground equipment and Global Positioning System antenna. The project site is zoned A-5 and is designated as Orchard and Field Crops by the Butte County General Plan. 1. Failure to comply with the conditions specified herein as the basis for approval of application and issuance of permit constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Sec. 24-45. 2. Unless otherwise provided for in a special condition to this Use Permit, all conditions must be completed prior to or concurrently with the establishment of the granted use. The use granted by this permit must be established within 24 months of the delivery of the countersigned permit to the Permittee. 3. Minor changes may be approved administratively by the Directors of Development Services, Environmental Health, or Public Works upon receipt of a substantiated written request by the applicant, or their respective designee. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. 4. If any use for which a Use Permit has been granted is not established within two years of the date of receipt of the countersigned permit by the Permittee, the permit shall become null and void and reapplication and a new permit shall be required to establish the use. 5. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Permittee. ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 8 of I I ■ • Conditions of Approval: Planning Division 1. The project site shall be developed in accordance with the approved project site plan and the conditions contained herein. Said site plan is on file in the Planning Division, is identified as "Attachment D" and date-stamped September 7, 2006, and is incorporated herein by this reference. 2. The new antennas and mounting hardware shall be painted to match the color scheme of the existing tower. 3. The installation of the Facility shall comply with all applicable building and electrical codes. The Facility operator shall submit certification from a registered. structural engineer to the Building Division that all associated monopoles and towers in excess of thirty (30) feet in height will withstand sustained winds as required by the Uniform Building Code. 4. No advertisements or displays shall be permitted on the Facility. 5. The placement of any antenna or structure shall not adversely affect any on-site sewage disposal system or its replacement area without written approval from the Division of Environmental Health. 6. The installation of the Facility shall not violate any existing deed restrictions. 7. The Facility shall have a twelve (12) foot wide all-weather access to a publicly maintained road capable of supporting a forty thousand (40,000) pound fire apparatus with fifteen (15) feet of vertical clearance. 8. There shall be no outdoor vehicle or equipment storage except for emergency purposes. 9. The Facility shall fall within current standards and regulations of the FAA, the FCC, and any other State and/or Federal agency with the authority to regulate such Facility. If such standards and regulations are changed, the property owner or responsible party shall bring the Facility into compliance with such revised standards and regulations within ninety (90) days of the effective date of such standards and regulations, unless a more stringent compliance schedule is mandated by the controlling agency. 10. The Facility or combination of the Facilities on the site shall not generate, at any time, electromagnetic frequency radiation (EMF) or radio frequency radiation (RF) in excess of the FCC adopted standards for human exposure, as amended over time. 11. If it is found that the Facility is or will be detrimental to the health, safety, or welfare of persons working or residing near such facility, then the service provider(s) and property owner shall be jointly and solely responsible for the removal, adjustment, or replacement of the Facility. In no case shall the Facility remain in operation if it is found to create a hazard to health, safety, and welfare. The Facility shall not be found to create a hazard to health, safety, or welfare as a result of EMF or RF emissions from the Facility so long as it meets all current standards established by the FCC, pursuant to FCC OET 65. 12. Prior to issuance of the Use Permit, the applicant shall post a performance security in an amount and form determined by the Director of Development Services that is sufficient to cover the cost of a one-time test by a radio frequency consultant selected by the ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 9 of 11 ■ County, sufficient to determine whether the Facility's RF/EMF emissions comply with FCC standards. If the Facility's emissions are determined to exceed FCC standards, the applicant is required to pay for such other tests and other corrective measures as are necessary to establish compliance with FCC OET 65 and its successors and such noncompliance shall constitute sufficient grounds to commence a permit revocation hearing which may lead to permit revocation. The applicant shall cooperate in all respects with the County's consultant to assist the consultant to reach his/her conclusion. 13. All Facilities that are not in continual use for a period of six (6) months shall be considered abandoned. Abandoned Facilities are hereby designated as unlawful and as public nuisances, requiring no amortization period. 14. The Facility may not encroach into, under, over, above, or upon any public street in the unincorporated area of the County in the absence of a valid encroachment permit from the County. 15. The owner/operator of the Facility shall annually submit a written verification, attested to under penalty of perjury, signed by both the owner/operator and an FCC licensee in the employ of or retained by the owner/operator, that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by the facility conforms to safety standards set forth in FCC OET 65. The reports prepared for the Facility shall conform to reporting requirements set by the FCC and the County. The reports shall be submitted to the Planning Division no later than January 31 of each year. 16. The Facility shall be secured at all times to prevent access by the public. 17. The collocation of the antennas allowed by this Use Permit requires the issuance of a building permit from the Butte County Building Division. The Building Division, based upon engineered calculations submitted by the applicant, may determine that the lattice tower cannot physically support the requested number of antennas. If that is the case, the number of new antennas allowed on the tower may be less than the number of antennas permitted by this Use Permit. California Department of Forestry/Butte County Fire 18. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 pound fire apparatus to within 150 feet of all structures. Environmental Health Division 19. Prior to issuance of a building permit, provide a completed Hazardous Materials Release Response Plan to Butte County Environmental Health as required by Chapter 6.95 of the California Health & Safety Code. Pacific Gas and Electric 20. Any relocation or rearrangement of any existing PG&E facilities in the area to accommodate this project will be at the expense of the developer. 21. There shall be no building of structures, or the storage of materials allowed over or under any existing PG&E facilities, or inside any easements that exist which would infringe on PG&E easement rights. ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 10 of 11 ■ Countv Counsel 22. If this entire matter or any finding, action or condition of this matter is appealed to the Board of Supervisors, the applicant or any other developer/operator other than the applicant agrees to indemnify the County of Butte from liability or loss related to the approval of this project and agrees to sign an indemnification agreement in a form approved by County Counsel before the Board's appeal hearing. If the application is not appealed, this condition is deemed satisfied. NOTE: Issuance of this Use Permit does not waive requirement of obtaining Building and Health Division permits before starting construction, nor does it waive any other requirements. Butte County Planning Commission Chairman cc: Land Development Division Building Division Environmental Health Division Butte County Fire Department/CDF Assessors Office Owner z:\up\clearwire llc up 07-06\planning commission documents\clearwire llc - up06-0022 - agenda report draft.doc ■ Butte County PLANNING COMMISSION AGENDA REPORT ■ ■ November 30, 2006 ■ Clearwire, LLC UP06-0022 ■ Page 11 of 11 ■ Ite ,- CA'� i r _ lo Project Location %�; ,' �;�'x e , e m� // Ito / a //// n d4 Ave 590 295 0 590 1,180 1,770 2,360 2,950 3,540 4,130 4,720 5,310 Feet N BUTTE COUNTY PLANNING COMMISSION W E Applicant: Clearwire, LLC Owner: Chico Leland Stanford Masonic Temple Assn. Hearin Date:November 30 2006 9:00 a.m. 1 Existing Zone: A-5 (Agricultural, 5 acre min.) S Request: Use Permit to collocate four panel antennas at a height of 113 feet on an Supervisorial existing 130 foot communications tower with around equipment. District #2 Assessor Parcel No: 042-070-197 File: UP 06-0022 BUTTE COUNTY PLANNING COMMISSION NOTICE OF A PUBLIC HEARING Notice is hereby given by the Butte County Planning Commission that a public hearing is published for Thursday, November 30, 2006, in the Butte County Board of Supervisors' Room, County Administration Center, 25 County Center Drive, Oroville, California, regarding the following item: ITEM DETERMINED TO BE CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW Name: Clearwire,LLC Project: Use Permit, UP06-0022 Planner: Chris Tolley APN: 042-070-197 Zoning: A-5 Location: 1110 WestEast Avenue (on the north side of West East Avenue, 0.25 miles northeast of the Highway 32, West East Avenue intersection), on the west side of the City of Chico. Proposal: Use Permit to collocate four panel antennas at a height of 113 feet on an existing 130 - foot communications tower and the installation of ground equipment including radio cabinets and a Global Positioning System antenna within the existing compound. The above mentioned application is on file and available for public viewing at the office of the Butte County Development Services Department, Planning Division, 7 County Center Drive, Oroville, California. For information call: Chris Tolley, (530) 538-7603, (Monday through Friday, 7:30 a.m. to 4:30 p.m.) Comments maybe submitted in writing at anytime prior to the hearing or orally at the meeting listed above or as may be continued.to a later date. Upon action taken by the Planning Commission on the project an appeal may be filed with the Clerk of the Board of Supervisors. The appeal period is 10 days. If you challenge the above application in court, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice or in written correspondence delivered to the Planning Commission, at or prior to, the public hearing. BUTTE COUNTY PLANNING COMMISSION TIM SNELLINGS, DIRECTOR OF DEVELOPMENT SERVICES To be published in the Chico Enterprise Record, Thursday, November 16, 2006. "DRAFT" LEAD IN SHEET r. 9 a FILE NO: V �� ' / — AP# APPLICANT:. OWNER: REPRESENTATIVE: Le ation) FINAL REQUEST: (to be filled out by project planner)��'v'""� i0 O �w�C2� yr/t z r- -,T7-P- — QT7R• '-"*- SUPERVISORIAL DISTRICT # EXISTING ZONING: GENERAL PLAN DESIGNATION: ru IDR Date 30 Day Complete Tentative Hearing Date KAP1anning\Forms\Lead In Sheet.doc 10u. PLANNER'S INITIALS mil q/okv �7�,2�FG�� / ((la ��5� ��f- P��u� •�. Ccfrl� G`�� ��n1Gi� 1. COMMENT DISTRIBUTION LIST APPLICANT: PLANNING PROJECT DESCRIPTION:' b O5� ��� f f��2 Loi / FILE NO.: l c)-? - CSC. DATE: a- D-? _ b AP NO: pq2- County Offices and Cities: Planning Division X Assessor's Office.- Mapping — BCAG . X Environmental Health _ City of Biggs ALUC X Building Manager City of Chico APCD X LAFCa City of Gridley Butte Co. Farm Bureau X Agricultural Commission City of Oroville Chico Airport Commission . X Public Works/Land De Town of Paradise Chief Administrative Officer X County Counsel Fire Protection: X California Department of Forestry _ EI Medio Fire Protection District Domestic Water: S.F.W & P. Agency (OWID) _ Butte Water District _ Del Oro Water Co. _ California Water Service Co. _ Thermalito Irrigation. District _ Other Utilities: _ PG&E North - Chico _ Pacific Bell _ Chambers Cable TV PG&E South - Oroville Viacom Cable TV Irrigation District: Biggs / West Gridley Water _ Durham Irrigation Dist. _ Paradise Irrigation Dist. Richvale Irrigation Dist. _ Table Mountain Irrigation Dist. _ Sewer: L.O.A.P.U.D. _ Sterling City Sewer Main_ Skansen Subdivision (CSA 21) Drainage Districts: Sacramento & San Joaquin Drainage Dist. Drainage District 200 Reclamation District No. 2056• State Agencies: _ Reclamation District No. 833 Reclamation District No. 2054 CalTrans _ Dept. of Water Resources Federal Agencies: U.S. Forest Service Other Districts, Agencies, Committees, etc.: K:\Planning\FORMS\APPLICATIONS\Lead-in Sheet Distribution List.doc Dept. of Fish and Game U.S. Bureau of Land Management 4� t,- BUTTE COUNTY • STANDARD CONDITIONS FOR USE PERMIT APPLICANT: Clearwire LLC, DATE: 9/7/2006 AGENT: Epic Wireless/ David Wiltsee APN: 072-070-197 FILE #: UP 07-06 PLANNER: Chris Tolley PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Those items checked are conditions of approval. PLEASE CONTACT THE PUBLIC WORKS DEPARTMENT FOR COMPLIANCE WITH THE FOLLOWING CHECKED CONDITIONS: A. STREETS ❑ I. Prior to the issuance of building permits, obtain an encroachment permit and improve all new and existing driveway approaches to publicly maintained roads as specified in the County Improvement Standards and the terms of the encroachment permit. ❑ 2. Prior to the issuance of building permits, deed to Butte County in fee simple feet of right-of-way from the centerline of along the entire property frontage. The right-of-way shall be sufficient for the installation of Improvement Standard No. S-5 at all street intersections. ❑ 3. Prior to the issuance of building permits, submit road and drainage improvement plans for the installation and construction of the street frontage improvements on to County Improvement Standards. Improve parcel frontage to a street section on to an RS-_ road standard including, but not limited to curb, gutter and sidewalk for parcels with gross acreage of one acre or less. Construct or install the required improvements. ❑ 4. Prior to the issuance of building permits, relinquish abutter's rights of access to Butte County along the frontage of parcels , except at approved access points. B. DRAINAGE ❑ 1. Prior to the issuance of building permits, a plan for a permanent solution for drainage shall be submitted to and approved by the Department of Public Works. The drainage plans shall detail existing drainage conditions and shall specify how drainage waters shall be detained or retained on- site and/ or conveyed to the nearest natural or publicly maintained drainage channel or facility and shall provide that there shall be no increase in the peak flow runoff to said channel or facility. ❑ 2. Prior to the issuance of building permits, establish 100 year flood plain elevations and the lowest floor elevations for any structures, in accordance with Butte County Code §26-25. Show on the additional map sheet the elevations (by contours) and the location of an accepted NGVD29 (National Geodetic Vertical Datum of 1929) benchmark and a temporary benchmark on-site. C. LEGAL LOT STATUS ❑ 1. Prior to the issuance of the Use Permit, prove to the satisfaction of the Director of Public Works that the parcel of the subject application is a legal parcel. 'ii� BUTTE COUNTY STANDARD CONDITIONS FOR USE PERMIT APPLICANT Clearwire LLC, DATE: 9/7/2006 AGENT: Epic Wireless/ David Wiltsee APN: 072-070-197 FILE #: UP 07-06 PLANNER: Chris Tolley PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Those items checked are conditions of approval. PLEASE CONTACT THE ENVIRONMENTAL HEALTH DIVISION FOR COMPLIANCE WITH THE FOLLOWING CHECKED CONDITIONS: D. SEWAGE DISPOSAL AREAS ❑ 1. Prior to the issuance of a building permit, the applicant shall meet the sewage disposal requirements of Butte County Code Section 26-26 for the installation of sewage disposal systems within a flood plain/floodway. Q 2. Prior to the issuance of a building permit, those wells indicated on the site plan that are proposed to be destroyed in order to provide required usable sewage disposal areas, shall be destroyed under a valid Butte County Environmental Health Division permit. ❑ 3. In the nitrate area record executed Future Sewer Service and Storm Drainage Agreements. ❑ 4. Prior to the issuance of a building permit, meet the requirements of the (Watershed Protection Zone) (Villa Verona Moratorium Area) (Cohasset Specific Plan). E. INDIVIDUAL WATER SUPPLY ❑ 1. Prior to the issuance of a building permit, provide a source of domestic water for the building on (lot) (parcel) ❑ 2. Prior to the issuance of a building permit, verify that domestic water can be provided to meet minimum standards for and other suspected contamination.. F. PUBLIC WATER SUPPLY ❑ I. Prior to the issuance of a building permit, verify that domestic water can be provided to meet minimum standards for and other suspected contamination. G. EXISTING COMMUNITY SEWER ❑ 1. Prior to the issuance of a building permit, under a permit issued by the Environmental Health Division, abandon the septic tank and connect the dwelling(s) on (lots) (parcel(s)) to public sewer. BUTTE COUNTY • STANDARD CONDITIONS FOR USE PERMIT APPLICANT: Clearwire LLC DATE: 9/7/2006 AGENT: Epic Wireless/ David Wiltsee APN: 072-070-197 FILE #: UP 07-06 PLANNER: Chris Tolley PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Those items checked are conditions of approval. PLEASE CONTACT THE BUILDING DIVISION FOR COMPLIANCE WITH THE FOLLOWING CHECKED CONDITIONS: H. BUILDING PERMITS ❑ 1. Building Permits Required. Prepare # sets of construction plans and make an application for permit. Construction shall comply with federal, state, and local regulations. Plans shall be prepared, sealed and signed by a California Licensed Architect or Registered Engineer for non-residential buildings and certain residential buildings. ❑ 2. Proposed improvements constitute a "change in use" or "change in the character of use" as stated in the building code. Improvement plans shall incorporate all code -required elements for the new use. ❑ 3. All structures shall be made accessible to the disabled. Disabled accessible parking and an accessible path of travel shall be provided. ❑ 4. Proposed improvements shall comply with Title 24 energy conservation regulations. Appropriate compliance forms (two sets) shall be submitted indicating compliance with those standards. ❑ 5. Proposed improvements shall comply with Butte County Code and FEMA Flood Hazard Prevention regulations. A FEMA Elevation Certificate, prepared by a qualified professional, shall be completed and submitted with improvement plans for the Building Division. ❑ 6. Proposed improvements shall comply with recorded map conditions applicable to construction. ❑ 7. Proposed improvements shall comply with Public Resources Code 4290 Fire Safe Construction standards. ❑ 8. Development fees for the proposed residential or non-residential improvements shall be paid prior to the issuance of building permits. The fees shall be those in effect at time of application, and shall include, but not be limited to, School Fees, Park and Recreation District fees, Water and Sewer Service Fees, Permit and Plan Check fees, and Fire Protection Fees. I. EXISTING STRUCTURES ❑ 1. Comply with the Uniform Building Code for property line clearances considering use, area and fire - resistiveness of existing buildings. ❑ 2. Existing building(s) shall be made to comply with current Building and Zoning regulations for the intended new use of the building(s) or the existing building(s) shall be demolished. • BUTTE COUNTY • STANDARD CONDITIONS FOR USE PERMIT APPLICANT Clearwire LLC, DATE: 9/7/2006 AGENT: Epic Wireless/ David Wiltsee APN: 072-070-197 FILE #: UP 07-06 PLANNER: Chris Tolley PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Those items checked are conditions of approval. PLEASE CONTACT THE BUTTE COUNTY FIRE DEPARTMENT FOR COMPLIANCE WITH THE FOLLOWING CHECKED CONDITIONS: J. FIRE CLEARANCE ❑ 1. Construction, installation or development of buildings and/or roads, driveways, gates and bridges on parcels/lots shall comply with the latest California Fire Safe Regulations—Public Resources Code 4290, 4291 and current Butte County Improvement Standards, whichever is stricter. ❑ 2. Prior to construction, a pressurized community water system for fire protection is required. Bonding may be allowed with the approval of the County Fire Chief. Average required hydrant spacing is feet, hydrant size inches, and residual fire flow of GPM. Fire hydrant identification, road reflectors or post reflectors acceptable to the County Fire Chief shall be installed or bonded, prior to Parcel or Final map recordation. Submit plans to the Fire Department for review and approval prior to construction. ❑ 3. Place a note on a separate document and recorded concurrently with the Parcel, Final map or an additional map sheet stating that "Fire suppression sprinkler systems shall be installed in all new residential dwellings in accordance with NFPA Standard 131), unless a pressurized community water system with hydrants that meet Fire Department specifications serves the property." A note stating "Automatic Fire Sprinklers conforming to NFPA Standard 13D required" is to be added to all affected building plans. ❑ 4. In lieu of hydrant installation, prior to recordation of the Parcel or Final map, payment shall be made into the hydrant fund at the current rate per lineal foot of street frontage. ❑ 5. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 -pound fire apparatus to within 150 feet of all structures. ❑ 6. Place a note on a separate document, which is to be recorded concurrently with the Parcel or Final map, or on an additional map sheet stating, "Building identification and/or addresses shall be installed in conformance with Public Resources Code 4290 and shall be posted at the time of permit issuance and maintained continuously thereafter. • • Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile www.buttecounty.net/dds ADMINISTRATION * BUILDING * PLANNING September 8, 2006 TO: Enter Agency or Department FROM: Chris Tolley, Butte County Planning Division SUBJECT: Request for Comments on a Development/Land Use Application APPLICANT: Clearwire LLC, Use Permit UP 07-06 APN: 072-070-197 DATE OF Inter -Departmental Review: 9/27/2006 IDR RESPONSE REGARDING COMPLETENESS OF APPLICATION DUE BY: 09/25/06 AGENCY/DEPARTMENT CONDITIONS/MITIGATION MEASURES DUE BY: 10/12/06 The Planning Division has received a project application as described below. This application is being provided to you for review. This is your opportunity to make comments regarding the completeness of this application, to be determined at the Inter -Departmental Review (IDR) Committee meeting on 9/27/2006, and/or to recommend conditions and/or mitigation measures relevant to your agency's/department's area of expertise and jurisdiction. PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. PROJECT LOCATION: on the north side of West East Ave., 1300'(0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico). COUNTY SUPERVISOR DISTRICT NO.: 2 ZONING: A-5 ((Agricultural, 5 -acre parcels)) GENERAL PLAN: OFC(Orchard & Field Crops) If a response cannot be submitted prior to the due dates listed above, please call Chris Tolley at (530) 538-7603 or send him an email at ctolley@buttecounty.net. You do not have to respond to this request if you have no comments to include. Thank you for your attention to this matter. Please return response to project planner. IDR COMMITTEE — APPLICATION COMPLETE ❑ No Name: Date: ❑ Yes Name: Date: Documentl Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile September 8, 2006 To: Inter -Departmental Review Committee Subject: Evaluation and Completeness of Application Applicant: Clearwire LLC,, UP 07-06 Planner: Chris Tolley APN: 072-070-197 Location: on the north side of West East Ave., 1300' (0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) 30 -Day Complete 10/6/2006 Date of IDR 9/27/2006 This application is being provided to you for comments. Please see attached documents. A hard copy of the application, including maps, has been sent to Environmental Health, Building Manager, LAFCo, Agricultural Commission, Public Works, Assessor, and CDF. All Environmental Health correspondence is routed through Karen Frederick at 7 County Center Drive. The purpose of this notice is to give you the opportunity to comment on the completeness of this application electronically to the planner, so that preparations can be made for the IDR meeting on 9/27/2006. 'Do you find this application complete? ❑ NO. Please respond prior to or at the IDR meeting09/25/06, regarding completeness of application. What is needed to make the application complete? ❑ YES. My Department's conditions and/or mitigation measures are attached or will be provided at the IDR meeting. If conditions cannot be provided at or prior to the IDR meeting they must be provided no more than 1 week after the meeting. Standard Conditions are attached for your convenience. (PLEASE SEND YOUR RESPONSE TO: Signature: _ Date: UPlanning/Projects/A New File/IDR Memos/IDR Completeness 8/30/05 Department: ctolleyctolley@buttecounty.net). GPD ASSOCIATES STRUCTURAL ANALYSIS REPORT Mobi fe SITE NUMBER: SC06534A SITE -NAME: SA534 HWY 99 & WILSON I NEW ANTENNA INSTALLATION BY: clear re* ON AN EXISTING 130 FT. SELF SUPPORT TOWER July 18, 2006 2006094.42 SELF SUPPORT TOWER STRUCTURAL ANALYSIS REPORT SC06534A SA534 HWY 99 & WILSON Chico, California Project 2006094.42 New Antenna Installation Existing 130 ft. Self Support Tower For: T -Mobile USA Bellevue, Washington Prepared By: 4rF EC. B " �!O. S4626 w. Steven C. Ball, S.E. � Registered Structural Engineer California # S4626 July 18, 2006 GPD ASSOCIATES ENGINEERS • ARCHITECTS • PLANNERS 520 South Main Street. Suite 2531 •Akron • Ohio 9 44311-1010 • Tel: 330-572-2100 9 Fax: 330-572-2101 TABLE OF CONTENTS DESCRIPTION EXECUTIVE SUMMARY TOWER DESCRIPTION TOWER MATERIALS TOWER LOADING ANALYSIS CONCLUSIONS AND RECOMMENDATIONS DISCLAIMER OF WARRANTIES . APPENDICES 1. ERI ANALYSIS PRINTOUT 2. TOWER ELEVATION DRAWINGS 3. SEISMIC CALCULATIONS GPD ASSOCIATES PAGE NUMBER 1 1 2 2 3 4 5 G y TOWER DESCRIPTION,' c' - ' The existing 130' self supporttower is located in`Chico, California. It was originally designed for Pacific Bell Mobile Systems by Leblanc Communications,.lnc. of Richardson, Texas. The original design loading was fora 90 mph wind speed, with Yz" of radial ice, in accordance with TIA/EIA- 222-F. iThe tower was originally designed to hold the following: F Original Design . The structure is supported on three legs and has seven major sections. -The tower has a triangular cross section made of bolted. connections with an "X" frame configuration. The tower is fabricated with solid rod legs and angle diagonals. All structural information was provided by.T-Mobile in the form of the original tower and foundation drawings by Leblanc (Job #: 4780740, dated,September 22, 1998).• The existing, reserved, and proposed antenna information was provided by T -Mobile: This analysis and report' are based solely on this information. GPD ASSOCIATES `STRUCTURAL ANALYSIS REPORT PAGE.1 SC06534A SA534 HWY 99 & WILSON t' 4k'' o , Y, }r' i •• •r .. .F . '} Cry"' 41`1,.,. � ''- .. i � � ": - ,' EXECUTIVE SUMMARY The of.this arialysis was to verify. whether the design for the existing tower is structurally purpose adequate to carry the new antenna and coax loads as specified by T -Mobile USA. This report'was commissioned.by Mr. Andrew Tung of T -Mobile. J, The design for the existing tower is structurally capable of supporting the proposed loads. The foundation reactions, with the proposed loading configuration, were found to be less than the original design reactions. Therefore, it is our opinion that the design for the existing foundations z will be adequate, if it was properly designed for the original design reactions, and constructed .accordingly. 1 Section Results y TOWER DESCRIPTION,' c' - ' The existing 130' self supporttower is located in`Chico, California. It was originally designed for Pacific Bell Mobile Systems by Leblanc Communications,.lnc. of Richardson, Texas. The original design loading was fora 90 mph wind speed, with Yz" of radial ice, in accordance with TIA/EIA- 222-F. iThe tower was originally designed to hold the following: F Original Design . The structure is supported on three legs and has seven major sections. -The tower has a triangular cross section made of bolted. connections with an "X" frame configuration. The tower is fabricated with solid rod legs and angle diagonals. All structural information was provided by.T-Mobile in the form of the original tower and foundation drawings by Leblanc (Job #: 4780740, dated,September 22, 1998).• The existing, reserved, and proposed antenna information was provided by T -Mobile: This analysis and report' are based solely on this information. GPD ASSOCIATES `STRUCTURAL ANALYSIS REPORT PAGE.1 SC06534A SA534 HWY 99 & WILSON - TOWER MATERIALS Data on steel strength was available from the. information provided. The following details the steel strength used in this analysis: Proposed. Configuration NOTE: BOLD type indicates a new appurtenance. The purpose of this independent -structural analysis review is to determine if the design for the existing tower, with the proposed configuration, is in conformance to the latest TIA/EIA-222-F standard requirements, and the.provisions. of the 1997 Uniform Building Code (UBC). GPD ASSOCIATES STRUCTURAL ANALYSIS REPORT PAGE 2 • SC06534A SA534 HWY 99 & WILSON • ANALYSIS The purpose of this structural analysis review is to determine if the design for the existing tower is in conformance.to the latest code requirements. Wind loading was taken from the TIA/EIA-222-F standard, in addition to wind loading taken from the 1997 Uniform Building Code (UBC). It was determined that the loading profile from TIA/EIA-222-F controls. Seismic loading was taken directly from UBC. In accordance with the code provisions, wind loading and seismic loading were not applied concurrently. ERI Tower (Version v3.0.0.16), a commercially available software program, was used to create a three-dimensional model of the tower and calculate member stresses for various dead, live, wind, and ice load cases. All loads -were computed in accordance with the ANSI/EIA/TIA-222-F standard and in accordance with UBC requirements. Selected output from the ANSI/EIA/TIA-222-F analysis is included in Appendix 1. The current requirements of TIA/EIA-222-F and UBC are for a fastest mile wind speed of 75 mph with 1/2" of radial ice. A 25% reduction in wind load is allowed when wind and ice are applied simultaneously. TIA/EIA-222-F requires towers within Butte County be analyzed with a 75 mph fastest mile wind speed. UBC requires all structures in Central California to be analyzed with a.75 mph fastest mile wind speed. In accordance with ANSI/EIAlTIA -222-F, Annex F, the analysis of existing structures should be done using the latest edition of the standard and all local/state provisions. The tower and foundations are assumed, for the purpose of this analysis, to have been properly fabricated, constructed, maintained, and to be in good condition with no structural defects. Seismic loads were determined from hand calculations. It was concluded from these calculations that the seismic loads do not control the maximum loading on the structure. The wind loading case will control. Refer to Appendix 3 for Seismic Calculations. GPD ASSOCIATES I STRUCTURAL ANALYSIS REPORT PAGE 3 SC06534A SA534 HWY 99 & WILSON CONCLUSIONS AND RECOMMENDATIONS r, Based on the structural analysis results, the design for the existing 130' self support tower does meet the requirements of EIA/TIA-222-F for a fastest mile wind speed of 75 mph with 1/2" of radial ice for the proposed antenna configuration, and satisfies the seismic.provisions of the Uniform Building Code. The foundation reactions, with the proposed loading configuration, were found to be less, than the original design reactions. Therefore, it is our opinion that the design for the existing foundations will be adequate, if it was properly designed for the original design reactions, and constructed accordingly. Summary of Findings Therefore, based on our analysis results the installation of the new appurtenances. as noted in the proposed configuration, is structurally acceptable. GPD ASSOCIATES STRUCTURAL ANALYSIS REPORT PAGE 4 • SC06534A SA534 HWY 99 & WILSON • DISCLAIMER OF WARRANTIES The engineering services rendered by GPD ASSOCIATES in connection with this Structural Analysis are limited to analyses of the tower structure, size and capacity of its members. GPD ASSOCIATES does not analyze the fabrication, including welding, except as included in this report. GPD ASSOCIATES makes no warranties, expressed or implied, in connection with this report and disclaims any liability arising from material, fabrication, and erection of this tower. GPD ASSOCIATES will not be responsible whatsoever for, or on account of, consequential or incidental damages sustained by any person, firm, or organization as a result of any data or conclusions contained in this report. The maximum liability of GPD ASSOCIATES pursuant to this report will be limited to the total fee received for preparation of this report. GPD ASSOCIATES STRUCTURAL ANALYSIS REPORT PAGE 5 • SC06534A SA534 HWY 99 & WILSON • APPENDICES 1. ERI Analysis Printout 2. Tower Elevation Drawings 3. Seismic Calculations ERI ANALYSIS PRINTOUT JVY RITower SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 520 SOUTH MAIN ST. 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 ps Tower lnpu# DatPH a .. Page 1 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy The main tower is a 3x free standing tower with an overall height of 130.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face width of the tower is 6.25 ft at the top and 13.94 ft at the base. This tower is designed using the TIA/EIA-222-F standard. The following design criteria apply: Tower is located in Butte County, California. Basic wind speed of 75 mph. Nominal ice thickness of 0.5000 in. Ice density of 56 pcf. A wind speed of 65 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 50 mph.. A non-linear (P -delta) analysis was used. Pressures are calculated at each section. Stress ratio used in tower member design is 1.333. Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. 1 4 Consider Moments - Legs 4 Consider Moments - Horizontals 4 Consider Moments - Diagonals .4 Use Moment Magnification 4 Use Code Stress Ratios 4 Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Op#ionsT. Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For Ki/r Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feedline Bundles As Cylinder Use ASCE 10 X -Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets F-1 Wind 180 Leg_A_ Wind 90 Q B Leg C Z Leg B Face C Wind Normal Triangular Tower :: Tower Section Geometry .. Tower Tower Assembly Page • . .i�,ITA'we SX06534A SA 534 HWY 99 &WILSON 2 of 30 GPD GROUP Project Date 520 SOUTH MAIN ST. 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA ft FAX.- 330-571-1101 r jmcilroy Wind 180 Leg_A_ Wind 90 Q B Leg C Z Leg B Face C Wind Normal Triangular Tower :: Tower Section Geometry .. Tower Tower Assembly Description Section Number Section Section Elevation Database Width of Length Spacing Type KBrace Sections Offset Offset ft ft r Tl 130.00-120.00 6.25 1 10.00 72 120.00-100.00 6.25 1 20.00 T3 100.00-80.00 6.25 1 20.00 T4 80.00-60.00 6.25 1 20.00 T5 60.0040.00 8.17 1 20.00 T6 40.00-20.00 10.10 1 20.00 T7 20.00-0.00 12.02 1 20.00 T.ower:,Section Geometry cont'd Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation . Spacing Type KBrace Horizontals Offset Offset End ft ft Panels in in Tl 130.00-120.00 5.00 X Brace No No 0.0000 0.0000 T2 120.00-100.00 5.00 X Brace No No 0.0000 0.0000 T3 100.00-80.00 5.00 X Brace No No 0.0000. 0.0000 T4 80.00.-60.00 5.00 X Brace No No 0.0000 0.0000 T5 60.00-40.00 5.00 X Brace No No 0.0000 0.0000 T6 40.00-20.00 5.00: X Brace No No 0.0000 0.0000 T7 20.00-0.00 10.00 X Brace No Yes 0.0000 0.0000 tr Alk ER Tower JIM SX06534A SA 534 HWY 99 & WILSON Page 3 of 30 GPD GROUP Project Date 520SOUTHMAINST 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX: 330-571-1102 Client T -MOBILE USA Designed by jmcilroy Tower Sectio.n..Geornet:ry cont°d Tower. Leg Leg Leg Diagonal Diagonal Diagonal Elevation Type Size Grade Type Size Grade ft TI -130.00-120.00 Solid Round 2 A572-50 Equal Angle L2x2xl/4 A36 (50 ksi) (36 ksi) T2 120.00-100.00 Solid Round 2 A572-50 Equal Angle L2x2xl/4 A36 (50 ksi) (36 ksi) T3 100.00-80.00 Solid Round 2 1/4 A572-50 Equal Angle 12x2xl/4 A36 (50 ksi) (36 ksi) T4 80.00-60.00 Solid Round 21/2 A572-50 Equal Angle L2x2xl/4 A36 (50 ksi). (36 ksi) T5 60.0040.00 Solid Round, 21/2 A572-50 Equal Angle L2x2xl/4 A36 (50 ksi) (36 ksi) T6 40.00-20.00 Solid Round 23/4 A572-50 Equal Angle L2 1/2x2 1/2x1/4 A36 (50 ksi) (36 ksi) . T7 20.00-0.00 Solid Round 23/4 A572-50 Equal Angle L3x3xl/4 A36 (50 ksi) (36 ksi) .. Tower Section Geomet cont'd Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girt Bottom Girt Elevation Type Size Grade Type Size Grade Tl 130.00-120.00 Equal Angle L2x2xl/4 A36 Single Angle A36 (36 ksi) (36 ksi) T4 80.00-60.00' Equal Angle L2x2xl/4 A36 Single Angle A36 . (36 ksi) (36 ksi) _..._ Tower.:Section Geometry_(cont'd)...:; r . : Tower Secondary Secondary Horizontal Secondary Inner Bracing ' Inner Bracing Size Inner Bracing Elevation Horizontal Type Size Horizontal Type Grade Grade ft T7 20.00-0.00 Equal Angle L2 1/2x2 1/2x1/4 A36 Single Angle A36 (36 ksi) (36 ksi) Tower Sect o'n Geometry:.(cont'd) Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness, Af Factor Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Diagonals Horizontals ft ft' in in in ERI -1 wer Gusset Page . Gusset Grade Adjust. Factor SX06534A SA 534 HWY 99 & WILSON 4 of 30 GPD GROUP Project Date 520SOUTHMAINST 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-1100 T -MOBILE USA jmcilroy FAX.- 330-572-2102 1 Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt (per face) 1 Ar Spacing Spacing Net Width U Tower Calc Calc Legs X K " Single Girts Horiz. Sec. Inner Diagonals Horizontals J? ft' in Horiz. Brace Single in in T1130.00- 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 120.00 f in (36 ksi) Y Y Y Y Y Y Y T1130.00- T2120.00- 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 100.00 1 1 (36 ksi) T2120.00- No No I 1 1 I 1 1 T3100.00- 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 80.00 No No (36 ksi) 1 1 1 80.00 T4 80.00-60.00 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 l 1 1 (36 ksi) 1 1 1 1 1 I T5 60.00-40.00 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 (36 ksi) T6 40.00- . No No T6 40.00-20.00 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 T7 20.00-0.00 (36 ksi) No 1 1 1 I I 1 I 1 T7 20.00-0.00 0.00 0.0000 A36 1.05 1 1.05 30.0000 30.0000 (36 ksi) 'Note: Kfact6rs are applied to member segment lengths. K -braces without inner supporting members will have the K factor in the out -of -plane direction applied to the overall length. Tower Section Geometry_. cont'd :.:..NEI Tower Leg Diagonal Tower:Sed on Geometry (cont°d Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation f. 1 K Factors Net Width U Net Width U Tower Calc Calc Legs X K " Single Girts Horiz. Sec. Inner Elevation K K Brace Brace Diags Width Horiz. Brace Single Solid Diags Diags Deduct Deduct Deduct Deduct Angles Rounds X X X X X. X X f in T1130.00- Y Y Y Y Y Y Y T1130.00- No No 120.00 120.00 1 1 1 1 1 1 1 T2120.00- No No I 1 1 I 1 1 ] 1 100.00 T3100.00- No No 1 1 I 1 1 1 1 1 80.00 1 1 1 1 1 1 1 T4 80.00- No No 1 1 1 1 I l 1 1 60.00 1 1 1 1 1 I 1 T5 60.00- No No 1 1 1 1 1 1 1 1 40.00 T6 40.00- . No No 1 1 1 1 1 1 I 1 20.00 T7 20.00-0.00 No No 1 1 1 I I 1 I 1 1 1 1 1 1 1 l 'Note: Kfact6rs are applied to member segment lengths. K -braces without inner supporting members will have the K factor in the out -of -plane direction applied to the overall length. Tower Section Geometry_. cont'd :.:..NEI Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation f. Net Width U Net Width U Net Width U Net U Net U Net U Net U Deduct Deduct. Deduct Width* Width Width Width . in in in Deduct Deduct Deduct Deduct in . in in in T1130.00- 0.0000. 1 0.0000 .0.75 0.0000 0.75 0.0000' 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 120.00 JVY �Tawer SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 510 SOUTH MAIN ST. 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX- 330-572-2102 5 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Tower Elevation J? Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Bolt Size No. Net Width U Net Width U Net Width U Net U Net U Net U Net U in Deduct Deduct ft Deduct (Frac FW) Width Row Width Flange Width 0 Width 0.6250 0 in in 0.6250 in 0.6250 Deduct 0.6250 Deduct 120.00 Deduct A325N Deduct A325N A325N A325N A325N in Feedline in Yes in Flange in 4 72120.00- 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 100.00 A325N A325N LDF5-50A A325N Yes A325N 100.00 - 8.00 A325N -0.05 A325N 1 T3100.00- Flange T3100.00- 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 80.00 A325N Ar (CfAe) A325N A325N 0 A325N 4 A325N 0.2500 A325N LMR 600 A325N Yes T4 80.00-60.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T5 60.0040.001 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T6 40.00-20.001 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T7 20.00-0.00 1 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 Tower; Section Geometry (cont'd Tower Elevation ft Leg Connection Type Leg Bolt Size No. Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Sue No. Offset in Spacing in in in in ft in (Frac FW) in Row T1130.00- Flange 0.0000 0 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 120.00 A325N A325N A325N A325N A325N A325N Feedline A325N Yes 72120.00- Flange 1.0000 4 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 100.00 A325N A325N A325N LDF5-50A A325N Yes A325N 100.00 - 8.00 A325N -0.05 A325N 1 T3100.00- Flange 1.0000 4 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 80.00 A A325N Ar (CfAe) A325N A325N 0 A325N 4 A325N 0.2500 A325N LMR 600 A325N Yes T4 80.00-60.00 Flange 1.0000 4 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 A325N A325N A325N FOAM) A325N A325N A325N A325N T5 60.00-40.00 Flange 1.0000 4 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 A325N A325N A325N A325N A325N A325N A325N T6 40.00-20.00 Flange 1.0000 4 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 A325N A325N A325N A325N A325N A325N A325N T7 20.00-0.00 Flange 1.1250 6 0.7500 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 A325N A325N A325N A325N A325N A325N A325N Feed.:LinelLine'ar.Ap'puttenances '<Entered As Round Or Flat Description Face Allow Component Placement Face Lateral # # Clear Width or Perimeter Weight or Shield Type Offset Offset Per Spacing Diameter Leg ft in (Frac FW) Row in in in plf LDF5-50A C Yes Ar (CfAe) 124.00 - 8.00 0.0000 0 24 12 1.0000 1.0900 0.33 (7/8 FOAM) Feedline C Yes Af (CfAe) 124.00 - 8.00 0.0000 0.05 1 1 1.0000 2.0000 4.0000 6.20 Ladder (Af) LDF5-50A C Yes Ar (CfAe) 100.00 - 8.00 0.0000 -0.05 1 1 1.0000 1.0900 0.33 (7/8 FOAM) CAT5 Cable A Yes Ar (CfAe) 113.00 - 8.00 0.0000 0 4 4 1.0000 0.2500 0.50 LMR 600 A Yes Ar (CfAe) 110.00 - 8.00 0.0000 0.05 2 2 1.0000 0.5900 0.13 (19/32 FOAM) Ah Ah RYTower o SX06534A SA 534 HWY 99 & WILSON Page 6 of 30 GPD GROUP Project Date 520SOUTHMAINST. 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA Out Face FAX.- 330-572-2102 Jf11CIIf0y Out Face ft Tower Tower Face An AF CAAA CAA, Weight Section Elevation Elevation or Thickness In Face Out Face In Face Out Face ft ft= f� ft= ft= lb Tl 130.00-120.00 A 0.000 0.000 0.000 0.000 0.00 0.000 0.000 B 0.000 0.000 0.000 0.000 0.00 0.000 0.000 C 4.360 0.667 0.000 0.000 56.48 T2 120.00-100.00 A 2.067 0.000 0.000 0.000 28.60 A 0.500 B 0.000 0.000 0.000 0.000 0.00 B C 21.800 3.333 0.000 0.000 282.40 T3 100.00-80.00 A 3.633 0.000 0.000 0.000 45.20 939.22 T3 B 0.000 0.000 0.000 0.000 0.00 0.000 120.53 C 23.617 3.333 0.000 0.000 289.00 T4 80.00-60.00 A 3.633 0.000 0.000 0.000 45.20 42.761 0.000 B 0.000 0.000 0.000 0.000 0.00 4.733 8.900 C 23.617 3.333 0.000 0.000 289.00 T5 60.0040.00 A 3.633 0.000 0.000 0.000 45.20 C B. 0.000 0.000 0.000 0.000 0.00 60.00-40.00 A C 23.617 3.333 0.000 0.000 289.00 T6 40.00-20.00 A 3.633 0.000 0.000 0.000. 45.20 0.00 B 0.000 0.000 0.000 0.000 0.00 0.000 965.24 C 23.617 3.333 0.000 0.000 289.00 T7 20.00-0.00 A 2.180 0.000 0.000 0.000 27.12 0.000 0.000 B 0.000 0.000 0.000 0.000 0.00 6.967 42.761 C 14.170 2.000 0.000 0.000 173.40 Feed= Li'neILinear Appurtenances Section Areas ,With ace Tower Tower Face Ice An AF CAA, CAA, Weight Section Elevation or Thickness In Face Out Face ft Leg in jtz fr ft' f? lb Tl 130.00-120.00 A 0.500 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.697 8.552 0.000 0.000 187.84 T2 120.00-100.00 A 0.500 2.679 5.388 0.000 0.000 72.94 B 0.000 0.000 0.000 0.000 .0.00 C 3.483 42.761 0.000 0.000 939.22 T3 100.00-80.00 A 0.500 4.733 8.900 0.000 0.000 120.53 B 0.000 0.000 0.000 0.000 0.00 C 6.967 42.761 0.000 0.000 965.24 T4 80.00-60.00 A 0.500 4.733 8.900 0.000 0.000 120.53 B 0.000 0.000 0.000 0.000 0.00 C 6.967 42.761 0.000 0.000 965.24 T5 60.00-40.00 A 0.500 4.733 8.900 0.000 0.000 120.53 B 0.000 0.000 0.000 0.000 0.00 C 6.967 42.761 0.000 0.000 965.24 T6 40.00-20.00 A 0.500 4.733 .8.900 0.000 0.000 120.53 B 0.000 0.000 0.000 0.000 0.00 C 6.967 42.761 0.000 0.000 965.24 T7 20.00-0.00 A 0.500 2.840 5.340 0.000 0.000 72.32 B 0.000 0.000 0.000 0.000 0.00. C 4.180 25.657 0.000 0.000 579.15 . Ml- er JZr SX06534A SA 534 HWY 99 & WILSON Page 7 of 30 GPD GROUP 520 SOUTH MAIN ST. Project 2006094.42 Date 15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX.- 330-572-2102 Client T -MOBILE USA Designed by JfTlCIIfOY Section Elevation Face AR AR AF AF Ice Ice Ice in ft in ft= ftp f� ftp Tl 130.00-120.00 A 0.000 0.000 0.000 0.000 -0.7975 6.6705 B 0.000 0.000 0.000 0.000 6.4014 T4 C 0.000 0.000 0.513 1.273 T2 120.00-100.00 A 0.000 0.000 0.176 0.918 40.00-20.00 -0.9625 B 0.000 0.000 0.000 0.000 -0.6983 5.5023 C 0.000 0.000 2.146 5.327 T3 100.00-80.00 A 0.000 0.000 0.310 1.552 lb B 0.000 0.000 0.000 0.000 C 0.000 0.000 2.301 5.724 T4 - 80.00-60.00 A 0.000 0.000 0.326 1.630 Pirod T -Frame Sector Mount C B 0.000 0.000 0.000 0.000 38.60 38.60 C 0.000 0.000 2.416 , 6.010 T5 60.00-40.00 A 0.000 0.000 0.276 1.383 C From Leg B 0.000 0.000 0.000 0.000 2.75 23.00 C 0.000 0.000 2.050 5.101 T6. 40.0040.00 A 0.000 0.000 0.332 1.580 0.00 B 0.000 U.000 0.000 0.000 (4) RR65-19-OODP C 0.000 0.000 2.466 5.828 T7 20.00-0.00 A 0.000 0.000 0.183 0.847 0.00 B 0.000 0.000 0.000 0.000. C 0.000 - 0.000 1.358 3.125 Feed Line Centersof Pressure.::._ Section Elevation CPX CPz CPX CPz Ice Ice ft in in - in in Tl 130.00-120.00 -0.0659. 3.0513 -0.0576 3.4246 T2 120.00-100.00 -0.5867 6.5185 -0.7975 6.6705 T3 100.00-80.00 -0.7794 6.3073 -1.0448 6.4014 T4 80.00-60.00 -0.8083 6.4963 -1.1022 6.7284 T5 60.00-40.00 -0.9924 7.8993 -1.3815 8.2463 T6 40.00-20.00 -0.9625 7.6130 -1.4044 8.4052 T7 20.00-0.00 -0.6983 5.5023 -1.0942 6.4691 .... Discrete Tower Loads . Weight Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Harz Adjustment Front Side Leg Lateral Vert ft ft ft, ft2 lb ft ft Pirod T -Frame Sector Mount C None 0.0000 123.00 No Ice 38.60 38.60 1060.00 (3) 1/2" Ice 57.40 57.40 1650.00 (4) RR65-19-00DP C From Leg 3.00 0.0000 123.00 No Ice 5.87 2.75 23.00 0.00. 1/2" Ice 6.32 3.23 51.51 0.00 (4) RR65-19-OODP B From Leg 3.00 0.0000 123.00 No Ice 5.87 2.75 23.00 0.00 1/2" Ice 6.32 3.23 51.51 ERRI.T A vy SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 520 SOUTHMAINST. 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T-MOBILE USA FAX: 330-572-2102 Page 8 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Description Face Offset Offsets: Azimuth Placement Elevation CAAA C,AAA Weight Weight or Type Horz Adjustment Harz Adjustment Beam Front Side Area Leg Lateral Lateral Width Vert Vert ft 0 ft ft2 ft, lb ft ft ft lb 4 FT DISH C Paraboloid w/o From 0.00 0.0000 100.00 4.00 ft . 12.56 170.00 Radome Leg 0.00 0.00 12" Ice 13.09. 237.19 (4) RR65-19-OODP A From Leg 3.00 0.0000 123.00 No Ice 5.87 2.75 23.00 Paraboloid From 0.00 0.00 110.00 2.00 1/2" Ice 6.32 3.23 51.51 w/Shroud (HP) Leg 0.00 12" Ice 3.41 44.49 20' Omni C From Leg 0.00 0.0000 140.00 No Ice 6.00 6.00 50.00 HP2-23 B 0.00 From 0.00 1/2" Ice 8.03 8.03 93.17 3.14 27.00 0.00 20' Omni B From Leg 0.00 0.0000 140.00 No Ice 6.00 6.00 50.00 0.00 1/2" Ice 8.03 8.03 93.17 0.00 Pirod T -Frame Sector Mount C None 0.0000 113.00 No Ice 38.60 38.60 1060.00 (3) 1/2" Ice 57.40 57.40 1650.00 SD98 C From Leg 0.00 0.0000 113.00 No Ice 4.58 3.81 29.44 0.00 1/2" Ice 5.10 4.58 67.42 0.00 SD98 B From Leg 0.00 0.0000 113.00 No Ice 4.58 3.81 29.44 0.00 1/2" Ice 5.10 4.58 67.42 0.00 SD98 A From Leg 0.00 45.0000 113.00 No Ice 4.58 3.81 29.44 0.00 1/2" Ice 5.10 4.58 67.42 0.00 SD98 A From Leg 0.00 45.0000 113.00 No Ice 4.58 3.81 29.44 0.00 1/2" Ice 5.10 4.58 67.42 0.00 NextNet BTS -2500 C From Leg 0.00 0.0000 113.00. No Ice 2.12 0.96 30.00 0.00 1/2" Ice 2.32 1.12 43.31 0.00 NextNet BTS -2500 B From Leg 0.00 0.0000 113.00 No Ice 2.12 0.96 30.00 0.00 1/2" Ice 2.32 1.12 43.31 0.00 NextNet BTS -2500 A From Leg 0.00 -45.0000 113.00 No Ice 2.12 0.96 30.00 0.00 12" Ice 2.32 1.12 43.31 0.00 NextNet BTS -2500 A From Leg 0.00 45.0000 113.00 No Ice 2.12 0.96 30.00 0.00 12" Ice 2.32 1.12 43.31 0.00 Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Harz Adjustment Beam Diameter Area Leg Lateral Width Vert ft ft ft fry lb 4 FT DISH C Paraboloid w/o From 0.00 0.0000 100.00 4.00 No Ice. 12.56 170.00 Radome Leg 0.00 12" Ice 13.09. 237.19 0.00 HP2-23 C Paraboloid From 0.00 0.0000 110.00 2.00 No Ice 3.14 27.00 w/Shroud (HP) Leg 0.00 12" Ice 3.41 44.49 0.00 HP2-23 B Paraboloid From 0.00 0.0000 110.00 2.00 No Ice 3.14 27.00 ERM.wer vV SX06534A SA X534 HWY 99 & WILSON GPD GROUP Project 520 SOUTHMAINST. 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 Page 9 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Harz Adjustment Beam Diameter Area Leg Leg % Lateral Width CA14A Out Face C T1130.00- 125.00 Vert 21 64.167 A ft o o ft ft ftp lb w/Shroud (HP) Leg 0.00 1/2" Ice 3.41 44.49 120.00 0.000 0.00 _.. Tower Pressures No Ice .: GH =1.743 Section Elevation t z t Kz q, pf Aa J?2 F a c e AF AR ? At, ftp Leg % CAAA In Face r CA14A Out Face C T1130.00- 125.00 1.463 21 64.167 A 5.518 3.333 3.333 33.84 0.000 0.000 120.00 0.000 120.00 B 6.518 3.333 B 33.84 5.000 36.52 C 6.672 7.693 23.20 15.969 5.697 12120.00- 110.00 1.411 20 128.333 A 10.730 8.733 6.667 34.25 0.000 0.000 100.00 10.000 31.56 0.000 0.000 B 10.907 6.667 37.94 B 14.542 10.000 40.75 C 12.094 28.467 16.44 T3100.00- 90.00 1.332 19 128.750 A 10.564 11.133 7.500 34.57 0.000 0.000 80.00 A 21.847 15.567 10.833 B 10.874 7.500 40.82 B 14.499 10.833 C 11.906 31.117 17.43 T4 80.00-60.00 70.00 1.24 18 148.401 A 12.679 11.979 8.346 33.85 0.000 0.000 1.24 13 0.5000 150.070 A B 13.004 8.346 28.48 39.09 0.000 C 13.922 31.963 18.19 T5 60.0040.00 50.00 1.126 16 186.861 A 13.975 11.979 8.346 32.16 0.000 0.000 B 14.252 8.346 36.93 C 15.535 31.963 17:57 T6 40.00-20.00 30.00 1 14 .225.749 A 20.475 12.814 9.181 27.58 0.000 0.000 B 20.807 9.181 30.61 C 21.675 32.797 16.85 T7 20.00-0.00 10.00 1 14 264.219 A 22.295 11.361 9.181 27.28 0.000 0.000 B 22.479 9.181 29.00 C 1 23.120 1 23.351 1 1 19.76 Tower_. Pressure_ ..: With GH = 1.143 Section Elevation ft z fl Kz qr psf tz in Aa ji' F a c e AF ftz AR ftp A,, ft, Leg % CAAA In Face ft= CAAA Out Face ftp T1130.00- 125.00 .1.463 16 0.5000 65.000 A 8.691 5.000 5.000 36.52 0.000 0.000 120.00 B 8.691 5.000 36.52 C 15.969 5.697 23.08 12120.00- 110.00 1.411 15 0.5000 130.000 A 19.011 12.679 10.000 31.56 0.000 0.000 100.00 B 14.542 10.000 40.75 C 51.976 13.483 15.28 T3100.00-80.00 90.00 1.332 14 0.5000 130.417 A 21.847 15.567 10.833 28.96 0.000 0.000 B 14.499 10.833 42.77 C 51.536 17.800 15.62 T4 80.00-60.00 70.00 1.24 13 0.5000 150.070 A 24.609 16.418 11.685 28.48 0.000 0.000 B 17.339 11.685 40.26 Job . Tower SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 520 SOUTHMAINST. 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 Page 10 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Section Elevation t z ft Kz qr psf tz in AG ? F a c a AF AR tz A,,, ft2 Leg % CAAA /n Face tz CAAA Out Face t 125.00 1.463 9 64.167 A 6.518 C 54.090 18.651 0.000 16.06 120.00 Face T5 60.0040.00 50.00 1.126 12 0.5000 188.530 A 26.519 16.418 11.685 27.21 0.000 0.000 t lb C 6.672 7.693 B 19.002 11.685 T2120.00- 38.08 1.411 9 128.333 A 10.730 8.733 6.667 34.25 C 56.662 18.651 8.458 15.51 68.26 C T6 40.00-20.00 30.00 1 11 0.5000 227.417 A 33.676 17.253 12.519 24.58 0.000 0.000 12.094 28.467 16.44 0.224 2.518 B 26.356 12.519 9 32.20 A 10.564 11.133 7.500 34.57 0.000 0.000 80.00 C 63.289 19.486 15.811 15.12 10.874 7.500 T7 20.00-0.00 10.00 1 11 0.5000 265.887 A 32.214 15.359 12.519 26.32 0.000 0.000 17.43 T4 80.00-60.00 70.00 1.24 B 27.721 12.519 12.679 31.11 8.346 33.85 0.000 0.000 C 1 50.2531 16.699 8.346 1 18.70 39.09 -------------- Tower Pree -Ser ic ssure; GH = 1.143 Section Elevation ft z ft Kz qt Psf Ac f� F a c e AF r AR fr' Aleg r' Leg % CAAA In Face t CAAA Out Face ft2 T1130.00- 125.00 1.463 9 64.167 A 6.518 3.333 3.333 33.84 0.000 0.000 120.00 Face B 6.518 3.333 33.84 t lb C 6.672 7.693 23.20 T2120.00- 110.00 1.411 9 128.333 A 10.730 8.733 6.667 34.25 0.000 0.000 100.00 8.458 682.57 68.26 C B 10.907 6.667 B 37.94 2.759 0.582 1 1 8.458 C 12.094 28.467 16.44 0.224 2.518 T3100.00- 90.00 1.332 9 128.750 A 10.564 11.133 7.500 34.57 0.000 0.000 80.00 0.582 1 1 15.811 B 10.874 7.500 100.00 40.82 B 0.137 2.82 0.58 1 1 C 11.906 31.117 17.43 T4 80.00-60.00 70.00 1.24 8 148.401 A 12.679 11.979 8.346 33.85 0.000 0.000 B 13.004 8.346 39.09 C 13.922 31.963 18.19 T5 60.00-40.00 50.00 1.126 7 186.861 A 13.975 11.979 8.346 32.16 0.000 0.000 B 14.252 8.346 36.93 C 15.535 31.963 17.57 T6 40.00-20.00 30.00 1 6 225.749 A 20.475 12.814 9.181 27.58 0.000 0.000 B 20.807 9.181 30.61 C 21.675 32.797 16.85 77 20.00-0.00 10.00 1 6 264.219 A 22.295 11.361 9.181 27.28 0.000 0.000 B 22.479 9.181 29.00 C 1 23.120 1 23.351 1 1 19.76 Section Add Self F e CF RR DF DR AE F w Ctrl. Elevation Weight Weight a Face c t lb lb a ? lb py, T1130.00- 56.48 721.47 A 0.154 2.759 0.582 1 1 8.458 682.57 68.26 C 120.00 B 0.154 2.759 0.582 1 1 8.458 C 0.224 2.518 0.596 1 1 11.253 T2120.00- 311.00 . 1317.26 A 0.152 2.765 0.582 1 1 15.811 1558.40 77.92 C 100.00 B 0.137 2.82 0.58 1 1 14.770 ERITower GPD GROUP 510 SOUTH MAIN ST. AKRON, OH 44311 Phone: 330-572-1100 FAX.- 330-571-2101 ion Page SX06534A SA 534 HWY 99 & WILSON 11 of 30 " Project Date 2006094.42 15:22:58 07/17/06 Client Designed by T -MOBILE USA jmcilroy Section Elevation t Add Weight lb Self Weight lb F a c a e CF RR DF DR AE Jiz F lb w - p1 Ctrl. Face Tl 130.00- 56.48 721.47 C 0.316 2.254 0.621 1 1 29.770 601.64 60.16 C T3100.'00- 334.20 1496.15 A 0.169 2.705 0.584 1 1 17.071 1521.81 76.09 C 80.00 B 0.143 2.799 0.58 1 1 15.227 T2120.00- 311.00 1317.26 C 0.334 2.209 0.627 1 1 31.415 "1431.78 71.59 C T4 80.00- 334.20 1823.12 A 0.166 2.713 0.584 1 1 19.675 1562.48 78.12 C 60.00 B 0.144 2.794 0.581 1 1 17.850 T3 100.00- _ 334.20 1496.15 C 0.309 2.272 0.619 1 1 33.699 1406.45 70.32 C T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 1 1 20.921 1564.76 78.24 C 40.00 B 0.121 2.881 0.577 1 1 19.071 T4 80.00- 334.20 1823.12 C 0.254 2.425 0.603 1 1 34.807 . 71.67 C T6 40.00- 334.20 2513.92 A 0.147 2.781 0.581 1 1 27.921 1677.00. 83.85 C 20.00 B 0.133 2.836 0.579 1 1 26.123 T5 60.00- 334.20 1891.85 C 0.241 2.464 0.6 1 1 41.343 1425.08 71.25 C 77 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 1 l 28.865 1622.72 81.14 C B 0.12 2.886 0.577 1 1 27.779 T6 40.00- 334.20 2513.92 C 0.176 2.679 0.586 1 1 36.799 1501.17 75.06 C Sum Weight: 1904.80 12381.75 B 0.133 2.836 0.579 0.8 OTM 647856.71 10189.74 C 0.241 2.464 0.6 0.8 1 Ib -ft Section Elevation t Add Weight lb Self Weight lb F a c e e CF RR DF DR AE ? F lb w p6r Ctrl. Face Tl 130.00- 56.48 721.47 A 0:154 2.759 0.582 0.8 1 7.154 601.64 60.16 C 120.00 B 01154 2.759 0.582 0.8 1 7.154 C 0.224 2.518 0.596 0.8 1 9.919 T2120.00- 311.00 1317.26 A 0.152 2.765 0.582 0.8 1 13.665 "1431.78 71.59 C 100.00 B 0.137 2.82 0.58 0.8 1 12.589 C 0.316 2.254 0.621 0.8 1 27.352 T3 100.00- _ 334.20 1496.15 A 0.169 2.705 0.584 0.8 1 14.958 1406.45 70.32 C 80.00 B 0.143 2.799 0.58 0.8 1 13.052 C 0.334 2.209 0.627 0.8 1 29.034 T4 80.00- 334.20 1823.12 A 0.166 2.713 0.584 0.8 1 17.140 1433.38 71.67 C 60.00 B 0.144 2.794 0.581 0.8 1 15.249 C 0.309 2.272 0.619 0.8 1 30.914 T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 0.8 1 18.126 1425.08 71.25 C 40.00 B 0.121 2.881 0.577 0.8 1 16.221 C 0.254 2.425 0.603 0.8 l 31.700 T6 40.00- 334.20 2513.92 A . 0.147 2.781 0.581 0.8 1 23.826 1501.17 75.06 C 20.00 B 0.133 2.836 0.579 0.8 1 21.962 C 0.241 2.464 0.6 0.8 1 37.008 T7 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 0.8 1 24.406 1418.81 70.94 C B 0.12 2.886 0.577 0.8 1 23.283 C 0.176 2.679 0.586 0.8 1 32.175 Sum Weight: 1904.80 12381.75 OTM 59.0095.29 9218.31 lb -ft Ah Ah �r Tower Nw Job Page 12 30 PuC SX06534A SA 534 HWY 99 & WILSON of GPD GROUP Project Date 520SOUTHMAINST. 2006094.42 15:22:58 07/17/06 Client Designed by AKRON, OH 44311 Phone: 330-572-2100 T -MOBILE USA JfT1CIIf0y FAX.- 330-572-1101 0.582 0.85 .Section Elevation t Add Weight lb Self Weight lb F a c a e CF RR DF DR AE ft2 F lb w ptr Ctrl. Face T1130.00- 56.48 721.47 A 0.154 2.759 0.582 0.85 1 7.480 621.87 62.19 C 120.00 B 0.154 2.759 0.582 0.85 1 7.480 C 0.224 2.518 0.596 0.85 1 10.253 72120.00• 311.00 1317.26 A 0.152 2.765 0.582 0.85 1 14.201 1463.43 73.17 C 100.00 B 0.137 2.82 0.58 0.85 1 13.134 C 0.316 2.254 0.621 0.85 1 27.956 T3100.00- 334.20 1496.15 A 0.169 2.705 0.584 0.85 1 15.486 1435.29 71.76 C 80.00 B 0.143 2.799 0.58 0.85 1 13.596 C 0.334 2.209 0.627 0.85 1 29.629 T4 80.00- 334.20 1823.12 A 0.166 2.713 ' 0.584 0.85 1 17.774 1465.66 73.28 C 60.00 B 0.144 2.794 0.581 0.85 1 15.899 C 0.309 2.272 0.619 0.85 1 31.610 T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 0.85 1 18.825 1460.00 73.00 C 40.00 B 0.121 2.881 0.577 0.85 1 16.934 C 0.254 2.425 0.603 0.85 1 32.476 T6 40.00- 334.20 2513.92 A 0.147 2.781 0.581 .0.85 1 24.850 1545.13 77.26 C 20.00 B 0.133 2.836 0.579 0.85 1 23.002 C 0.241 2.464 0.6 0.85 1 38.092 T7 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 0.85 1 25.521 1469.79 73.49 C B 0.12 2.886 0.577 0.85 1 24.407 C 0.176 2.679 0.586 0.85 1 33.331 Sum Weight: 1904.80 12381.75 OTM 604535.65 9461.17 lb -ft Tow;er..Forces With Ice Wi.nd.. NormaL.To Face Section Elevation t Add Weight lb Self Weight lb F a c a e CF RR DF DR AE r' F lb w Ctrl. Face T1130.00- 187.84 989.69 A .0.211 2.561 0.593 1 1 11.654 780.46 78.05 C 120.00 B 0.211 2.561 0.593 1 1 11.654 C 0.333 2.211 0.627 1 1 19.539 T2120.00- 1012.16 1781.04 A 0.244 -2.456 0.6 1 1 26.623 2027.14 101.36 C 100.00 B 0.189 2.634 0.588 1 1 20.424 C 0.504 1.895 0.699 1 1 61.405 73100.00- 1085.77 1969.10 A 0.287 2.331 0.612 1 1 31.373 1967.74 98.39 C 80.00 B . 0.194 2.615 0.589 1 1 20.882 C 0.532 1.862 0.714 1 1 64.248 T4 80.00- 1085.77 2377.89 A 0.273 2.369 0.608 1 1 34.593 1968.45 98.42 C 60.00 B 0.193 2.618- 0.589 1 1 24.222 C 0.485 1.921 0.69 1 1 66.956 T5 60.00- 1085.77 2486.35 A 0.228 2.506 0.596 1 1 36.312 1975.71 98.79 C 40.00 B 0.163 2.725 0.584 1 1 25.820 C 0.399 2.065 0.651 1 1 68.812 T6 40.00- 1085.77 3310.92 A 0.224 2.518 0.596 1 1 43.951 2000.33 100.02 C 20.00 B 0.171 2.696 0.585 1 1 33.679 C 0.364 2.14 0.638 1 1 75.712 77.20.00-0.00 651.46 3452.28 A 0.179 2.668 0.586 1 1 41.220 1811.16 90.56 C B 0.151 2.767 0.582 1 1 35.004 C 0.252 2.432 0.602 1 1 60.312 Sum Weight: 6194.56 16367.27 OTM 812338.35 12530.99 lb -ft JVY ENTower SX06534A SA 534 HWY 99 & WILSON. GPD GROUP Project 520 SOUTHMATNST 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX- 330-572-2102 _T;ower.Forces With ice .:Wind 60 To Face.. Page 13 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Section Elevation ft Add Weight lb Self Weight lb F a c e e CF RR DF DR AE fit F lb w ptr Ctrl. Face TI 130.00- 187.84 989.69 A 0.211 2.561 0.593 0.8 1 9.916 652.89 65.29 C 120.00 B 0.211 2.561 0.593 0.8 1 9.916 C 0.333 2.211 0.627 0.8 1 16.345 72120.00- 1012.16 1781.04 A 0.244 2.456 0.6 0.8 1 22.821 1683.97 84.20 C 100.00 B 0.189 2.634 0.588 0.8 1 17.516 C 0.504 1.895 0.699 0.8 1 51.010 T3100.00- 1085.77 1969.10 A 0.287 2.331 0.612 0.8 1 27.004 1652.06 82.60 C 80.00 B 0.194 2.615 0.589 0.8 1 17.982 C 0.532 1.862 0.714 0.8 1 53.941 T4 80.00- 1085.77 2377.89 A 0.273 2.369 0.608 0.8 1 29.672 1650.41 82.52 C 60.00 B 0.193 2.618 0.589 0.8 1 20.754 C 0.485 1.921 0.69 0.8 1 56.138 T5 60.00- 1085.77 2486.35 A 0.228 2.506 0.596 0.8 1 31.008 1650.33 82.52 C 40.00 B 0.163 2.725 0.584 0.8 1 22.020 C 0.399 2.065 0.651 0.8 1 57.479 T6 40.00- 1085.77 3310.92 A 0.224 2.518 0.596 0.8 1 37.216 1665.91 83.30 C 20.00 B 0.171 2.696 0.585 0.8 1 28.407 C 0.364 2.14 0.638 0.8 1 63.055 T7 20.00-0.00 651.46 3452.28 A 0.179 2.668 0.586 0.8 1 34.777 1509.34 75.47 C B 0.151 2.767 0.582 0.8 1 29.459 C 0.252 2.432 0.602 0.8 1 50.261 Sum Weight: 6194.56 16367.27 OTM 678648.92 10464.91 Ib -ft Tower; Forces Wifh`Ice .Wind 90 To Face... Section Elevation ft Add Weight lb Self Weight lb F a c e e CF RR DF DR AE fr' F lb w if Ctrl. Face T1130.00- 187.84 989.69 A 0.211 2.561 0.593 0.85 1 10350 684.78 68.48 C 120.00 B 0.211 2.561 0.593 0.85 1 10.350 C 0.333 2.211 0.627 0.85 1 17.144 72120.00- 1012.16 1781.04 A 0.244 2.456 0.6 0.85 1 23.771 1769.76 88.49 C 100.00 B 0.189 2.634 0.588 0.85 1 18.243 C 0.504 1.895 0.699 0.85 1 53.609 T3100.00- 1085.77 1969.10 A 0.287 2.331 0.612 0.85 1 28.096 1730.98 86.55 C 80.00 B 0.194 2.615 0.589 0.85 1 18.707 C 0.532 1.862 0.714 0.85 1 56.517 T4 80.00- 1085.77 2377.89 A 0.273 2.369 0.608 0.85 1 30.902 1729.92 86.50 C 60.00 B 0.193 2.618 0.589 0.85 1 21.621 C 0.485 1.921 0.69 0.85 1 58.842 T5 60.00- 1085.77 2486.35 A 0.228 2.506 0.596 0.85 1 32.334 1731.68 86.58 C 40.00 B 0.163 2.725 0.584 0.85 1 22.970 C 0.399 2.065 0.651 0.85 1 60.312 T6 40.00- 1085.77 3310.92 A 0.224 2.518 0.596 0.85 1 38.900 1749.52 87.48 C 20.00 B 0.171 2.696 0.585 0.85 1 29.725 C 0.364 2.14 0.638 0.85 1 66.219 T7 20.00-0.00 651.46 3452.28 A 0.179 2.668 0.586 0.85 1 36.388 1584.79 79.24 C B 0.151 2.767 0.582 0.85 1 30.845 C 0.252 2.432 0.602 0.85 1 52.774 . 11TAwer GPD GROUP 520 SOUTH MAIN ST. AKRON, OH 44311 Phone: 330-572-2100 FAX- 330-572-2102 Wo 'qw Page SX06534A SA 534 HWY 99 & WILSON 14 of 30 Project Date 2006094.42 15:22:58 07/17/06 Client Designed by T -MOBILE USA jmcilroy Section Add Self F e CF RR DF DR AE F w Ctrl. Elevation Weight Weight a 0.154 2.759 0.582 1 l 8.458 303.37 30.34 Face 120.00 c 0.154 2.759 0.582 l I 8.458 t lb lb a 0.224 2.518 0.596 1 1 tt !b P1f Sum Weight: 6194.56 16367.27 A 0.152 2.765 0.582 1 OTM 712071.27 10981.43 34.63 C 100.00 B 0.137 2.82 0.58 1 1 Ib -ft Tower Forces. Service Wind Normal To: Face n Section Elevation t Add Weight Ib Self Weight lb F a c a e CF RR DF DR AE ? F lb w ! Ctrl. Face T1130.00- 56.48 721.47 A 0.154 2.759 0.582 1 l 8.458 303.37 30.34 C 120.00 B 0.154 2.759 0.582 l I 8.458 C 0.224 2.518 0.596 1 1 11.253 T2120.00- 311.00 1317.26 A 0.152 2.765 0.582 1 1 15.811 692.62 34.63 C 100.00 B 0.137 2.82 0.58 1 1 14.770 C 0.316 2.254 0.621 1 1 29.770 T3100.00- 334.20 1496.15 A 0.169 2.705 0.584 1 1 17.071 676.36 33.82 C 80.00 B 0.143 2.799 0.58 1 1 15.227 C 0.334 2.209 0.627 1 1 31.415 T4 80.00- 334.20 1823.12 A 0.166 2.713 0.584 1 1 19.675 694.44 34.72 C 60.00 B 0.144 2.794 0.581 1 l 17.850 C 0.309 2.272 0.619 1 1 33.699 T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 1 1 20.921 695.45 34.77 C 40.00 B 0.121 2.881 0.577 1 1 19.071 C 0.254 2.425 0.603 1 1 34.807 T6 40.00- 334.20 2513.92 A 0.147 2.781 0.581 1 1 27.921 745.34 37.27 C 20.00 B 0.133 2.836 0.579 1 1 26.123 C 0.241 2.464 0.6 1 1 41.343 T7 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 1 1 28.865 721.21 36.06 C B 0.12 2.886 0.577 1 1 27.779 C 0.176 2.679 0.586 1 1 36.799 Sum Weight: 1904.80 12381.75 OTM 287936.32 4528.77 Ib -ft Tower Forces Service Wind 60 To ceqi :..__ . Section Elevation t Add Weight lb Self Weight lb F a c e e CF RR DF DR AE fly F lb w PIr Ctrl. Face T1130.00- 56.48 721.47 A 0.154 2.759 0.582 0.8 1 7.154 267.40 26.74 C 120.00 B 0.154 2.759 0.582 0.8 1 7.154 C 0.224 2.518 0.596 0.8 1 9.919 72120.00- 311.00 1317.26 A 0.152 2.765 0.582 0.8 1 13.665 636.35 31.82 C 100.00 B 0.137 2.82 0.58 0.8 1 12.589 C 0.316 2.254 0.621 0.8 1 27.352 T3100.00- 334.20 1496.15 A 0.169 2.705 0.584 0.8 I 14.958 625.09 31.25 C 80.00 B 0.143 2.799 0.58 0.8 1 13.052 C 0.334 2.209 0.627 0.8 1 29.034 T4 80.00- 334.20 1823.12 A 0.166 2.713 0.584 0.8 1 17.140 637.06 31.85 C 60.00 B 0.144 2.794 0.581 0.8 1 15.249 C 0.309 2.272 0.619 0.8 1 30.914• Ah r_ -I RITower ST, SX06534A SA 534 HWY 99 & WILSON Page 15 -of 30 GPD GROUP 520SOUTHMAINST Project 2006094.42 Date 15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX.- 330-572-2102 Client T -MOBILE USA Designed by jmcilroy Section Elevation t Add Weight lb Self Weight lb F 'a c e e Cr RR DF DR AE ? F !b w Xf Ctrl. Face T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 0.8 1 18.126 633.37 31.67 C 40.00 B 0.121 2.881 0.577 0.8 1 16.221 Total Member Self -Weight 12381.75 C 0.254 2.425 0.603 0.8 1 31.700 T6 40.00- 334.20 2513.92 A 0.147 2.781 0.581 0.8 1 23.826 667.19 33.36 C 20.00 B 0.133 2.836 0.579 0.8 1 21.962 C 0.241 2.464 0.6 0.8 1 37.008 T7 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 0.& 1 24.406 630.58 31.53 C 80.00 B 0.12 2.886 0.577 0.8 1 23.283 C 0.176 2.679 0.586 0.8 1 32.175 Sum Weight: 1904.80 12381.75 A 0.166 2.713 0.584 0.85 OTM 262264.57 4097.03 32.57 C 60.00 B 0.144 2.794 0.581 0.85 1 ib -ft Section Elevation ft Add Weight lb Self Weight lb F a c e e - CF RR DF DR AE F lb w ptr Ctrl. Face Tl 130.00- • 56.48 721.47 A 0.154 2.759 0.582 0.85 1 7.480 276.39 27.64 C 120.00 B 0.154 2.759 0.582 0.85 l 7.480 Total Member Self -Weight 12381.75 C 0.224 2.518 0.596 0.85 1 10.253 T2120.00- 31'1.00 1317.26 A 0.152 2.765 0.582 0.85 1 14.201 650.41 32.52 C 100.00 B 0.137 2.82 0.58 0.85 1 13.134 C 0.316 2.254 0.621 0.85 l 27.956 T3100.00-. 334.20 1496.15 A 0.169 2.705 0.584 0.85 1 15.486 637.91 31.90 C 80.00 B 0.143 2.799 0.58 0.85 1 13.596 C 0.334 2.209 0.627 0.85 1 29.629 T4 80.00- 334.20 1823.12 A 0.166 2.713 0.584 0.85 1 17.774 651.40 32.57 C 60.00 B 0.144 2.794 0.581 0.85 1 15.899 C 0.309 2.272 0.619 0.85 1 31.610 T5 60.00- 334.20 1891.85 A 0.139 2.813 0.58 0.85 1 18.825 648.89 32.44 C 40.00 B 0.121 2.881 0.577. 0.85 1 16.934 C 0.254 2.425 0.603 0.85 1 32.476 T6 40.00- 334.20 2513.92 A 0.147 2.781 0.581 0.85 1 •24.850 686.72 34.34 C 20.00 B 0.133 2.836 0.579 0.85 1 23.002 C 0.241 2.464 0.6 0.85 1 38.092 T7 20.00-0.00 200.52 2617.98 A 0.127 2.856 0.578 0.85 1 25.521 653.24 32.66 C B 0.12 2.886 0.577 0.85 1 24.407 C 0.176 2.679 .0.586 0.85 1 33.331 Sum Weight: 1904.80 12381.75 OTM 268682.51 4204.97 ' lb -ft ._ .. Force Totals k Load Vertical Sum of Sum of Sum of Sum of Sum of Torques Case Forces Forces . Forces Overturning Overturning X Z Moments, Mx Moments, M !b lb !b !b- lb ft !b- t Leg Weight 6520.97 Bracing Weight 5860.19 H Total Member Self -Weight 12381.75 4236.74 1326.75 z RI ower GPD GRO UP 510 SOUTHMAINST. AKRON, OH 44311 Phone: 330-571-2100 FAX.- 330-571-2102 Joh Page SX06534A SA 534 HWY 99 & WILSON 16 of 30 Project Date 2006094.42 15:22:58 07/17/06 Client Designed by T -MOBILE USA I I jmcilroy Load Case Vertical Forces lb Sum of Forces X lb Sum of Forces Z lb Sum of Overturning Moments, M, Ib- Sum of Overturning Moments, M, lb- Sum of Torques !b- t Total Weight 17244.31 4236.74 ( 1326.75 Wind 0 deg - No Ice 370.83 -14479.40 -1153900.90 -3'5756.56 -882.19 Wind 30 deg - No Ice 7177.82 -11861.94 -956505.74 -587015.66 2168.11 Wind 60 deg - No Ice 11905.07 -6817.39 -552192.20 -973224.95 4120.88 Wind 90 deg - No Ice 13916.80 -233.88 -19206.67 -1131040.11 5161.29 Wind 120 deg - No Ice 12801.43 6886.65 547681.28 -1028722.01 5400.65 Wind 150 deg - No Ice 6809.42 11730.16 951751.46 -549898.37 3544.88 Wind 180 deg - No Ice -47.48 13383.49 1092082.65 6074.93 1063.66 Wind 210 deg - No Ice -6898.20 11849.79 963713.94 561429.68 -1735.79 Wind 240 deg - No Ice -12621.11 7210.74 580090.54 1013343.38 -4518.46 Wind 270 deg - No Ice -13784.64 8.19 5000.02 1120476.82 -5607.65 Wind 300 deg - No Ice -11701.08 -6644.79 -534931.85 955479.01 -5184.53 Wind 330 deg - No Ice -6842.89 -11731.82 -943493.36 556176.25 -3530.84 Member Ice 3985.52 Total Weight Ice 27435.40 13799.78 2369.15 Wind 0 deg - Ice 289.86 -16670.66 -1291786.35 -26616.93 -1304.73 Wind 30 deg - Ice 7795.71 -13058.63 -1026330.51 -624327.99 2471.86 Wind 60 deg - Ice 12806.55 -7351.52 -576990.78 -1029056.06 4923.40 Wind 90 deg - Ice 15246.97 -182.99 4544.79 -1216227.38 6472.77 Wind 120 deg - Ice 14638.77 8058.32 638631.95 -1149101.47 7154.25 Wind 150 deg - Ice 7506.84 , 12955.46 1043572.61 -595215.22 4435.92 Wind 180 deg - Ice -37.11 14507.01 1175872.51 6080.56 1309.51 Wind 210 deg - Ice -7576.23 13048.97 1052923.05 606892.86 -2134.40 Wind 240 deg - Ice -14497.82 8311.65 663964.57 1139745.00 -5849.52 Wind 270 deg -Ice 15143.66 6.22 14376.32 1210634.82 6821.66 Wind 300 deg -Ice 12647.10 7216.61 -563499.26 1017849.19 6232.91 Wind 330 deg - Ice 7533.91 -12956.92 -1016159.41 602886.64 4424.49 Total Weight 17244.31: 4236.74 1326.75 Wind 0 deg - Service _ 164.81 -6435.29 -514357.76 -15950.22 -392.08 Wind 30 deg - Service y, $jt 3190.14 -5271.97 426626.58 -260954.26 963.60 Wind 60 deg - Service 5291.14 -3029.95 -246931.67 432602.84 1831.50 Wind 90 deg - Service 6185.25 -103.95 -10049.21 -502742.91 2293.91 Wind 120 deg - Service 5689.52 3060.73 241900.99 '457268.20 2400.29 Wind 150 deg - Service 3026.41 5213.40 421487.73 -244457.69 1575.50 Wind 180 deg - Service a -21.10 594822 483857.15 2641.56 472.74 Wind 210 deg - Service -3065.87 5266.57 426804.39 249465.89 -771.46 Wind 240 deg - Service -5609.38 3204.77 256305.10 450316.42 -2008.21 Wind 270 deg - Service -6126.51 3.64 709.32 497931.28 -2492.29 Wind 300 deg - Service y -5200.48 -2953.24 -239260.40 424598.92 -2304.24 Wind 330 deg - Service ,, . ; .i, -3041.29 -5214.14 -420843.301 247131.03 f -1569.26 ERI -Tower GPD GROUP 520 SOUTH MAIN ST. AKRON, OH 44311 Phone: 330-572-2100 FAX.- 330-572-2102 IoTi Page SX06534A SA 534 HWY 99 & WILSON 17 of 30 Project Date 2006094.42 15:22:58 07/17/06 Client Designed by T -MOBILE USA jmcilroy Comb. Description Na. 12 Dead+Wind 300 deg - No Ice 13 Dead+Wind 330 deg - No Ice 14 Dead+lce+Temp 15 Dead+Wind 0 deg+lce+Temp 16 Dead+Wind 30 deg+Ice+Temp 17 Dead+Wind 60 deg+Ice+Temp 18 Dead+Wind 90 deg+Ice+Temp 19 Dead+Wind 120 deg+Ice+Temp 20 Dead+Wind 150 deg+Ice+Temp 21 Dead+Wind 180 deg+Ice+Temp 22 Dead+Wind 210 deg+Ice+Temp 23 Dead+Wind 240 deg+Ice+Temp 24 Dead+Wind 270 deg+Ice+Temp 25 Dead+Wind 300 deg+Ice+Temp 26 Dead+Wind 330 deg+Ice+Temp. 27 Dead+Wind 0 deg - Service 28 Dead+Wind 30 deg - Service 29 Dead+Wind 60 deg - Service 30 Dead+Wind 90 deg - Service 31 Dead+Wind 120 deg - Service 32 Dead+Wind 150 deg - Service 33 Dead+Wind 180 deg - Service 34 Dead+Wind 210 deg - Service 35 Dead+Wind 240 deg - Service 36 Dead+Wind 270 deg - Service 37 Dead+Wind 300 deg - Service 38 Dead+Wind 330 deg - Service Max1miurn Member Forces. Section Elevation Component Condition Gov. Force Major Axis Minor Axis No. ft Type Load Moment Moment Comb. lb lb ft lb -ft Tl 130- 120 Leg Max Tension 8 1420.27 0.14 -347.83 Max. Compression 23 -2847.28 214.69 113.34 Max. Mx 5 -138.50 631.45 -0.74 Max. My 2 602.22 0.65 -630.97 Max. Vy 5 -510.79 ;350.72 2.37 Max. Vx 2 515.79 0.65 354.96 Diagonal Max Tension 18 1017.84 0.00 0.00 Max. Compression 23 -1077.28 0.00 0.00 Max. Mx 25 -222.02 9.73 -0.20 Max. My 18 -120.06 9.19 -0.93 Max. Vy 25 10.70 9.73 -0.20 Max. Vx 19 -0.27 0.00 0.00 Top Girt Max Tension 8 59.73 0.00 0.00. Max. Compression 19 -106.37 0.00 0.00 Max. Mx 14 -26.10 -25.82 0.00 Max. Vy 14 -16.53 0.00 0.00 T2 120-100 Leg Max Tension 8 16238.69 1.57 -1.59 Max. Compression 23 -22116.70 100.43 -50.08 Max. Mx 24 -2029.28 496.78 1.99 Max. My 15 1642.12 -9.09 -460.75 Max. Vy 18 -389.47 -232.33 -2.26 Max. Vx 15 377.19 5.87 224.58 Diagonal Max Tension 18 2837.84 0.00 0.00 Max. Compression 24 -2862.14 0.00 0.00 Max. Mx 19 2150.03 21.57 -1.93 Max. My 18 -2641.74 4.20 -4.34 A Ak 'Tob �t.�C�l'Vi�l" SX06534A SA 534 HWY 99 &WILSON Page 18 of 30 GPD GROUP Project Date 520SOUTFIMAlNST. 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX- 330-572-2101 Client T -MOBILE USA Designed by jmcilroy Section Elevation Component Condition Gov. Force. Major Axis Minor Axis No. ft Type Load Moment Moment Comb. lb lb -ft lb -ft Max. Vy 19 -13.71 21.57 -1.93 Max. Vx 18 1.09 4.20 -4.34 T3 100-80 Leg Max Tension 4 41337.29 44.56 18.57 Max. Compression 23 -52140.31 137.69 -67.93 Max. Mx 18 -3311.15 -145.18 -8.34 Max. My 15 -50539.71 -0.36 151.88 r Max. Vy 6 -223.47. -79.52 -50.58 . Max. Vx 2 176.19 -17.51 59.01 Diagonal Max Tension 24 3773.06 0.00 0.00 Max. Compression 18 -3909.86 0.00 0.00 Max. Mx 19 2716.84 32.01 4.02 Max. My 24 -3537.91 -3.46 7.19 Max. Vy 19 -16.31 32.01 -4.02 Max. Vx 24 -1.80 -3.46 7.19 T4 80-60 Leg Max Tensiop 4 56322.42 -75.61 -5.74 Max. Compression 23 -72074.96 86.36 6.88 Max. Mx 23 -58452.92 153.21 10.01 Max. My 20 4527.29 -5.91 -174.65 Max. Vy 15 96.95 151.87 0.36 Max. Vx 20 106.86 -5.91 -174.65 Diagonal Max Tension 19 2313.21 0.00 0.00 Max. Compression 19 -2450.76 0.00 0.00 Max.. Mx 23 1677.87 27.29 3.78 Max. My 24 -2258.77 -3.62 7.50 Max. Vy 17 15.73. 25.62 -0.97 Max. Vx 24 -2.18 0.00 0.00 Top Girt Max Tension 23 225.02 0.00 0.00 Max. Compression 4 -323.57 0.00 0.00 Max. Mx 14 4.89 -25.81 . 0.00 Max. My 19 -156.25 0.00 0.72 Max. Vy 14 -16.52 0.00 0.00 Max. Vx 19 0.46 0.00 0.00 T5 60-40 Leg Max Tension 17 67756.16 -9.58 -6.07 Max. Compression 23 -87948.20 -2.81 7.84 Max. Mx 17 67619.49 -220.66 -6.92 Max. My 20 -6076.20 35.97 -121.74 Max. Vy 15 117.45 177.98 2.47 Max. Vx 19 90.00 -13.56 -116.86 Diagonal Max Tension 18 2508.57 0.00 0.00 Max. Compression 19 -2496.51 0.00 0.00 Max. Mx 23 1438.58 32.17 2.20 Max. My 24 -2294.77 6.41 3.97 Max. Vy 17 18.53 31.60 -2:43 Max. Vx 24 -1.18 0.00 0.00 T6 40 - 20 Leg Max Tension 17 77868.52 166.49 4.18 Max. Compression 23 -103422.75 -89.74 5.13 Max. Mx 15 -96660.12 369.86 1.32 Max. My 20 -8635.34 .-197.88 -229.40 Max. Vy 15 -179.00 369.86 1.32 Max. Vx 26 -109.66 -198.38 229.23 Diagonal Max Tension 18 3078.49 0.00 0.00 Max. Compression 18 •-3043.71 0.00 0.00 Max. -Mx 23 1385.31 67.85 . 4.20 Max. My 25 -2602.54 43.94 5.44 Max. Vy 23 -29.42 67.85 4.20 Max. Vx 25 1.45 0.00 0.00 T7 20-0 Leg Max Tension 17 86088.55 -77.48 -15.03 Max. Compression 23 -116301.22 -0.00 0.03 Max. Mx 17 82979.45 t -348.47 -9.43 Max. My 26 -10622.76 129.11 _ 580.83 Max. Vy 17 -129.51 -348.47 -9.43 An r1 ER[Towex Aor Now SX06534A SA 534 HWY 99 & WILSON Page 19 of 30 GPD GROUP Project Date 520 SOUTH MAIN ST 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA mcilro y 1 1 FAX.- 330-572-2102 0.00 0.00 Section Elevation Component No. ft Type Condition Gov. Load Comb. Force lb Major Axis Moment lb -ft Minor Axis Moment lb -ft Torque Max. Vx 26 241.46 129.11 580.83 Diagonal Max Tension 18 3794.94 0.00 0.00 Leg C Max. Compression 19 -3946.01 0.00 0.00 0.00 Max. Mx 18 422.01 121.02 -4.63 370.81 Max. My 24 -3874.34 40.75 22.50 17244.31 Max. Vy 18 40.05 121.02 4.63 Dead+Wind 60 deg - No Ice Max. Vx 24 -3.76 0.00 0.00 Secondary ` Max Tension 17 119.25 0.00 0.00 Horizontal Max. Vert 19 118609.65 -8581.41 -4583.36 549662.01. Max. Compression 15 -159.38 0.00 0.00 11729.54 Max. Mx 14 -18.78 -148.58 0.00 -47.49 Max. My 19 50.50 0.00 4.12 17244.31 Max. Vy 14 44.20 0.00 0.00 Max. Vx 19 1.23 0.00 0.00 Location Condition Gov. Vertical Horizontal, X Horizontal, Z Torque Combination Load lb lb lb Moment, M Comb. lb lb lb Leg C Max. Vert 23 118990.13 8553.89 -4647.33 0.00 Max. H. 23 118990.13 8553.89 -4647.33 370.81 Max. H. 16 -78620.82 -7024.47 4490.25 17244.31 Min. Vert 17 -89102.77 -8088.89 4443.37 Dead+Wind 60 deg - No Ice Min. H. 17 -89102.77 -8088.89 4443.37 4133.60 Min. H. 23 118990.13 8553.89 -4647.33 Leg B Max. Vert 19 118609.65 -8581.41 -4583.36 549662.01. Max. H. 25 -87733.31 8008.58 4334.79 11729.54 Max. Hz 26 -76651.57 6916.38 4337.89 -47.49 Min. Vert 25 -87733.31 8008.58 4334.79 17244.31 Min. Hx 19 118609.65 -8581.41 -4583.36. Min. H. 19 118609.65 -8581.41 -4583.36 Leg A Max. Vert 15 116714.79 -69.08 9680.70 Max. H. 23 -46148.73 684.62 -5355.52 Max. H. 15 116714.79 -69.08 9680.70 Min. Vert 21 -88786.03 53.97 -9091.10 Min. H. 18 9521.94 -702:14 -246.61 Min. H. 21. -88786.03 53.97 -9091.10 TowerrMast Reaction Summary Load Vertical Shear, Shear, Overturning Overturning Torque Combination Moment, Mx Moment, M lb lb lb lb -ft lb -ft lb -ft Dead Only 17244.31 -0.00 0.00 4236.76 1326.75 0.00 Dead+Wind 0 deg - No Ice 17244.31 370.81 -14478.78 -1158049.61 -35882.01 -889.55 Dead+Wind 30 deg - No Ice 17244.31 7177.36 -11861.45 -959960.08 -589141.06 2171.48 Dead+Wind 60 deg - No Ice 17244.31 11904.92 -6817.28 -554206.72 -976800,23 4133.60 Dead+Wind 90 deg - No Ice 17244.31 13916.14 -233.66 -19260.62 -1135132.64 5180.80 Dead+Wind 120 deg - No Ice 17244.31 12800.85 6886.39 549662.01. -1032421.45 5421.70 Dead+Wind 150 deg - No Ice 17244.31 6809.20 11729.54 955197.49 -551882.96 3560.25 Dead+Wind.180 deg - No Ice 17244.31 -47.49 13383.31 1096088.78 6101.19 1070.58 Dead+Wind 210 deg - No Ice 17244.31 -6898.00 11849.15 967200.53 563462.70 -1738.99 Ah Ak ERITower SX06534A SA 534 HWY 99 & WILSON Page 20 of 30 GPD GROUP 520SOUTHMARVST. Project 2006094.42 Date 15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX.- 330-572-2102 Client T -MOBILE USA Designed by jmcilroy Load Vertical Shear, Shear, Overturning Overturning Torque Combination Load PX Py Moment, M,T Moment, M Py PZ lb lb lb lb -ft lb -ft lb -ft Dead+Wind 240 deg - No Ice 17244.31 -12620.53 7210.47 582185.68 1016991.15 4531.46 Dead+Wind 270 deg - No Ice 17244.31 -13783.98 8.39 5033.87 1124534.78 -5626.59 Dead+Wind 300 deg - No Ice 17244.31 -11700.93 -6644.68 -536882.06 958994.37 -5204.00 Dead+Wind 330 deg - No Ice 17244.31 -6842.47 -11731.32 -946899.75 558197.49 -3545.91 Dead+lce+Temp 27435.40 0.02 -0.12 13859.09 2380.15 0.02 Dead+Wind 0 deg+Ice+Temp 27435.40 289.85 -16670.36 -1298902.79 -26762.86 -1316.75 Dead+Wind 30 deg+Ice+Temp 27435.40 7795.39 -13058.47 -1032082.94 -627847.26 2496.44 Dead+Wind 60 deg+Ice+Temp 27435.40 12806.32 -7351.29 -580227.68 -1034875.84 4969.94 Dead+Wind 90 deg+Ice+Temp 27435.40 15246.65 -182.60 4549.96 -1223070.64 6530.43 Dead+Wind 120 deg+Ice+Temp 27435.40 14638.37 8058.40 642200.16 -1155489.27 7217.10 Dead+Wind 150 deg+Ice+Tcmp 27435.40 7506.83 12955.11 1049451.63 -598552.23 4480.86 Dead+Wind 180 deg+Ice+Temp 27435.40 -37.14 14506.69 1182518.03 6121.26 1321.23 Dead+Wind 210 deg+Ice+Temp 27435.40 -7576.27 13048.58 1058851.97 610307.34 -2158.74 Dead+Wind 240 deg+lce+Temp 27435.40 -14497.42 8311.71 667672.94 1146087.61 -5898.42 Dead+Wind 270 deg+Ice+Temp 27435.40 -15143.34 6.62 14478.39 1217454.72 -6878.53 Dead+Wind 300 deg+Ice+Temp 27435.40 -12646.88 -7216.37 -566658.43 1023615.69 -6290.66 Dead+Wind 330 deg+lce+Temp 27435.40 -7533.63 -12956.74 -1021853.04 606296.31 -4469.18 Dead+Wind 0 deg - Service 17244.31 164.81 -6435.00 -512329.26 -15207.67 -395.33 Dead+Wind 30 deg - Service 17244.31 3189.98 -5271.73 -424289.29 -261102.25 964.25 Dead+Wind 60 deg - Service 17244.32 5291.01 -3029.88 -243954.66 -433396.20 1837.57 Dead+Wind 90 deg - Service 17244.31 6184.95 -103.93 -6199.88 -503767.41 2303.67 Dead+Wind 120 deg - Service 17244.31 5689.27 3060.59 246657.17 458118.38 2409.97 Dead+Wind 150 deg - Service 17244.31 3026.28 5213.15 426898.87 -244543.70 1581.67 Dead+Wind 180 deg - Service 17244.31 -21.10 5947.92 489512.54 3451.90 475.89 Dead+Wind 210 deg - Service 17244.31 -3065.73 5266.31 432233.94 251171.25 -771.67 Dead+Wind 240 deg - Service 17244.31 -5609.13 3204.63 261112.96 452741.74 -2014.36 Dead+Wind 270 deg - Service 17244.31 -6126.21 3.65 4597.32 500538.68 -2502.22 Dead+Wind 300 deg - Service 17244.31 -5200.22 -2953.10 -236251.93 426957.31 -2313.45 Dead+Wind 330 deg - Service 17244.31 -3041.13 -5213.90 -418484.97 248829.67. -1575.38 Solution:Surnma Sum of Applied Forces Sum of Reactions Load PX Py PZ PX Py PZ % Error Comb. lb lb lb lb lb lb 1 0.00 -17244.31 0.00 0.00 17244.31 -0.00 0.000% 2 370.83 -17244.31 -14479.40 -370.81 17244.31 14478.78 0.003% 3 7177.82 -17244.31 -11861.94 -7177.36 17244.31 11861.45 0.003% 4 11905.07 -17244.31 -6817.39 -11904.92 17244.31 6817.28 0.001% 5 13916.80 -17244.31 -233.88 -13916.14 17244.31 233.66 0.003% 6 12801.43 -17244.31 6886.65 -12800.85 17244.31 -6886.39 0.003% 7 6809.42 -17244.31 11730.16 -6809.20 17244.31 -11729.54 0.003% 8 -47.48 -17244.31 13383.49 47.49 17244.31 -13383.31 0.001% 9 -6898.20 -17244.31 11849.79 6898.00 17244.31 -11849.15 0.003% 10 -12621.11 -17244.31 7210.74 12620.53 17244.31 -7210.47 0.003% 11 -13784.64 -17244.31 8.19 13783.98 17244.31 -8.39 0.003% 12 -11701.08 -17244.31 -6644.79 11700.93 17244.31 6644.68 0.001% 13 -6842.89 -17244.31 -11731.82 6842.47 17244.31 11731.32 0.003% 14 0.00 -27435.40 0.00 -0.02 27435.40 0.12 0.000% 15 289.86 -27435.40 -16670.66 -289.85 27435.40 16670.36 0.001% 16 7795.71 -27435.40 -13058.63 -7795.39 27435.40 13058.47 0.001% 17 12806.55 -27435.40 -7351.52 -12806.32 27435.40 7351.29 0.001% 18 15246.97 -27435.40 -182.99 -15246.65 27435.40 182.60 0.002% 19 14638.77 -27435.40 8058.32. -14638.37 27435.40 -8058.40 0.001% 20 7506.84 -27435.40 12955.46 -7506.83 27435.40 -12955.11 0.001% 21 -37.11 -27435.40 14507.01 37.14 27435.40 -14506.69 0.001% 22 -7576.23 -27435.40 13048.97 7576.27 27435.40 -13048.58 0.001% 23 -14497.82 -27435.40 8311.65 14497.42 27435.40 -8311.71 0.001% . TO.W'''1" SX06534A SA 534 HWY 99 & WILSON Page 21 of 30 . GPD GROUP 520 SOUTH MAINST Project 2006094.42 Date .15:22:58 07/17/06 AKRON, OH 44311 Phone: 330-572-2100 FAX, 330-572-2102 Client T -MOBILE USA Designed by jmcilfoy Sum of Applied Forces Force Sum of Reactions Converged? Number Load PX Py PZ PX Py PZ % Error Comb. lb lb lb lb lb lb 0.00013252 24 -15143.66 -27435.40 6.22 15143.34 27435.40 -6.62 0.002% 25 -12647.10 -27435.40 -7216.61 12646.88 27435.40 7216.37 0.001% 26 -7533.91 -27435.40 -12956.92 7533.63 27435.40 12956.74 0.001% 27 164.81 -17244.31 -6435.29 -164.81 17244.31 6435.00 0.002% 28 3190.14 -17244.31 -5271.97 -3189.98 17244.31 5271.73 0.002% 29 5291.14 -17244.31 -3029.95 -5291.01 17244.32 3029.88 0.001% 30 6185.25 -17244.31 -103.95 -6184.95 17244.31 103.93 0.002% 31 5689.52 -17244.31 3060.73 -5689.27 17244.31 -3060.59 0.002% 32 3026.41 -17244.31 5213.40 -3026.28 17244.31 -5213.15 0.002% 33 -21.10 -17244.31 5948.22 21.10 17244.31 -5947.92 0.002% 34 -3065.87 -17244.31 5266.57 3065.73 17244.31 -5266.31 0.002% 35 -5609.38 -17244.31 .3204.77 5609.13 17244.31 -3204.63 0.002% 36 -6126.51 -17244.31 3.64 6126.21 17244.31 -3.65 0.0020/.' 37 -5200.48 -17244.31 -2953.24 5200.22 17244.31 2953.10 0.002% 38 -3041.29 -17244.31 -5214.14 3041.13 17244.31 5213.90 0.002% Force Load Converged? Number Displacement Combination of Cycles Tolerance Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 9 0.00000001 0.00013252 3 Yes 9 0.00000001 0.00014414 4 Yes 10 0.00000001 0.00004812 5 Yes 9 0.00000001 0.00014419 6 Yes 9 0.00000001 0.00013261 7 Yes 9 0.00000001 0.00014346 8 Yes 10 0.00000001 0.00004806 9 Yes 9 0.00000001 0.00014338 10 Yes 9 0.00000001 0.00013255 11 Yes 9 0:00000001 0.00014369 12 Yes 10 0.00000001 0.00004810 13 Yes 9 0.00000001 0.00014371 14 Yes 7 0.00000001 0.00011599 15 Yes 10 0.00000001 0.00007023 16 Yes 10 0.00000001 0.00007467 17 Yes 10 0.00000001 0.00007775 18 Yes 10 0.00000001 0.00007489 19 Yes 10 0.00000001 0.00007058 20 Yes 10 0.00000001 0.00007459 21 Yes 10 0.00000001 0.00007773 22 Yes 10 0.00000001 0.00007460 23 Yes 10 0.00000001 0.00007056 24 Yes 10 0.00000001 0.00007481 25 Yes 10 0.00000001 0.00007777 26 Yes 10 0.00000001 0.00007457 27 Yes 9 0.00000001 0.00013627 28 Yes .9 0.00000001 0.00014127 29 Yes 10 0.00000001 0.00005422 30 Yes 9 0.00000001 0.00014127 31 Yes 9 0.00000001 0.00013645 32 Yes 9 0.00000001 0.00014112 33 Yes 9 0.00000001 0.00014545 34 Yes 9 0.00000001 0.00014109 35 Yes 9 0.00000001 0.00013650 36 Yes 9 0.00000001 0.00014113 JOD . Towver SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 520SOUTHMAINST 2006094.42 AKRON, OH 44311 Client Phone: 330-572-1100 T -MOBILE USA FAX.' 330-572-2102 37 Yes 9 0.00000001 0.00014548 38 Yes 9 0.00000001 0.00014113 Maximum Tower. in ;Deflections Serurce Wd Section Elevation - Hon. Gov. Tilt Twist No. Load Deflection Load ft Comb. ft in Comb. o° in TI 130-120 3.604 35 0.2275 0.0216 72 120-100 3.126 35 0.2266 0.0208 T3 100-80 2.186 35 0.2096 0.0189 T4 80-60 1.361 35 0.1668 0.0143 T5 60-40 0.748 35 0.1191 0.0094 T6 .40-20 0.330 35 0.0729 0.0052 T7 20-0 0.086 35 0.0359 0.0020 Page 22 of 30 Date - 15:22:58 07/17/06 Designed by . jmcilroy Critical Defie.ctions and Radius of Curvature ..Service Wind Elevation Appurtenance Gov. Deflection Tilt r Twist Radius of Load Deflection Load ft Comb. Curvature ft Comb. Comb. in oft 130-120 8.926 140.00 20' Omni 35 3.604 0.2275 0.0216 Inf 123.00 Pirod T -Frame Sector Mount (3) 35 3.269 0.2272 0.0211 804282 113.00 Pirod T -Frame Sector Mount (3) 35 2.791 0.2236 0.0203 136181 110.00 HP2-23 35 2.649 0.2214 0.0201 89400 100.00 4 FT DISH 35 2.186 0.2096 0.0189. 41641 - Maximum Tow ir`-Deflections Des gn Wind Section Elevation Harz. Gov. Tilt Twist No. Load Deflection Load ft Comb. f in Comb. o° 23 T1 130-120 8.926 23 0.5575 0.0585 .T2 120-100 7.756 23 0.5554, 0.0510 T3 100-80 5.450 23 0.5156 0.0515 T4 80-60 3.415 23 0.4137 0.0396 T5 60-40 1.887 23 0.2978 0.0264 T6 40-20 0.836 23 0.1833 0.0147 T7 20-0 0.220 23 0.0908 0.0058 Critical Deflections and_Radius of Cu.ruature -Design Wrnd Elevation Appurtenance Gov.. Deflection Tilt Twist Radius of Load Curvature ft Comb. in o o ft - 1.40.00 20' Omni 23 8.926 0.5575 0.0585 431078 123.00 Pirod T -Frame Sector Mount (3) 23 8.107 0.5567 0.0575 325968 Jo ERITower SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 2006094.42 520SOUTHMAINST AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 Page 23 of 30 Date 15:22:58 07/17/06 Designed by jmcilroy Elevation Appurtenance Gov. Deflection Tilt Twist Radius of .. ........ .. . ... .. .. .... ............ .. ..... ......... ........ . . ... . ...... . ....... Load Bolt -H! i ................. ....................... sign ....... .... I .. .. . .... ......... ... .... .. .... ........ ............. - ........ .. . .. ....... .. . ..... .... Curvature ft Comb. in o o . ft 113.00 Pirod T -Frame Sector Mount (3) 23 6.936 0.5485 0.0556 59503 110.00 HF2-23 23 6.587 0.5434 0.0549 38777 100.00 4 IT DISH 23 5.450 0.5156 0.0515 17886 . . ........ . ...... .... .. . . ..... N Compression Checks .: ... .... . .... .. . ...... . .... . ..... . ..... .... . ........... Leg Des_rg,n i ............. . Atd ! C omp .. ........ .. . ... .. .. .... ............ .. ..... ......... ........ . . ... . ...... . ....... Bolt -H! i ................. ....................... sign ....... .... I .. .. . .... ......... ... .... .. .... ........ ............. - ........ .. . .. ....... .. . ..... .... ................ .. ............ .. .............. . ... ... .... .. ... ....... .. .... ..... . .. .. ..... ........ .. ....... Ratio Section Elevation Size L L. Criteria Section Elevation Component Boll Bolt Size Number Maximum Allowable Ratio Allowable NO. Type Grade P Of Load per Load Load Ratio ksi ft lb lb in Bolts Bolt lb Allowable 5.00 120.0 10.370 3.1416 -2432.72 32579.10 0.075 lb K=1.00 TI 130 Diagonal A325N 0.6250 1 1077.28 6442.72 0.167 1.333 Bolt Shear T2 120 Leg A325N 1.0000 4 886.56 34557.50 0.026 1.333 Bolt Tension. Diagonal A325N 0.6250 1 2862.14 6442.72 0.444 1.333 Bolt Shear T3 100 Leg A325N 1.0000 4 5485.99 34557.30 0.159 1.333 Bolt Tension Diagonal A325N 0.6250 1 3909.86 6442.72 0.607 1.333 Bolt Shear T4 80 Leg A325N 1.0000 4 11645.60 34557.50 0.337 1.333 Bolt Tension Diagonal A325N 0.6250 1 2450.76 6442.72 0.380 1.333. Bolt Shear T5 60 Leg A325N 1.0000 4 14848.90 34557.50 0.430 1.333 Bolt Tension Diagonal A325N 0.6250 1 2508.57 6442.72 0.389 1.333 Bolt Shear T6 40 Leg A325N 1.0000 4 17711.00 34557.40 0.513. 1.333Bolt Tension Diagonal A325N 0.6250 1 3.078.49 6442.72 0.478 1.333 Bolt Shear T7 20 Leg A325N 1.1250 6 13829.90 43736.80 0.316 1.333 Bolt Tension Diagonal A325N 0.7500 1 3946.01 9277.52 0.425 1.333 Bolt Shear . . ........ . ...... .... .. . . ..... N Compression Checks .: ... .... . .... .. . ...... . .... . ..... . ..... .... . ........... Leg Des_rg,n i ............. . Atd ! C omp .. ........ .. . ... .. .. .... ............ .. ..... ......... ........ Ratio Section Elevation Size L L. K11r F. A Actual Allow. No. P P. P ft ft ft ksi in' lb lb P. TI 130-120 2 10.00 5.00 120.0 10.370 3.1416 -2432.72 32579.10 0.075 K=1.00 T2 120-100 2 20.00 5.00 120.0 10.370 3.1416 -22116.70 32579.10 .0.679 K=1.00 T3 100-80 2 1/4 20.00 5.00 106.7 13.124 3.9761 -52140.30 52183.40 0.999 K=1.00 T4 80-60 2 1/2 20.03 5.01 96.1 15.585 4.9087 -7192i.50 76503.50 0.940 K=1.00 T5 60-40 2 1/2 20.03 5.01 96.1 15.585 4.9087 -87794.80 76503.50 1.148 I K=1.00 T6 40-20 23/4 20.03 5.01 87.4 17.490. 5.9396 -103336.00 103886.00 0.995. Ah Ak Tower Jo Page . SX06534A SA 534 HWY 99 & WILSON 24 of 30 GPD GROUP Project Date 520SOUTHMAINST. 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA fbz FAX.- 330-572-2102 fby jmcilroy Section Elevation Size L L„ Kl/r Fa A Actual Allow. Ratio No. P pa P ft ft ft ksi inz lb lb p K=1.00 T7 20-0 23/4 20.03 5.20 90.8 16.772 5.9396 -113755.00 99619.00 1.142 K=1.00 111-1 (1.33 CR) - 159 11!*1Leg. Bending.. Design Data Compression).... Section -Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. 0.075 0.245 Mr fbs F& fbz MY fby Fby fby 0.046 ft 0.756 lb ft ksi ksi Fbr lb ft ksi ksi Fb TI 130-120 2 600.24 -9.171 37.500 0.245 0.00 0.000 37.500 0.000 T2 120-100 2 112.22 -1.714 37.500 0.046 0.00 0.000 37.500 0.000 T3 100-80 2 1/4 153.54 -1.639 37.500 0.044 0.00 0.000 37.500 0.000 T4 80-60 2 1/2 105.23 -0.823 37.500 0.022 0.00 0.000 37.500 0.000 T5 60-40 2 1/2 176.02 -1.377 37.500 0.037 0.00 0.000 37.500 0.000 T6 40-20 23/4 368.45 -2.166 37.500 0.058 0.00, 0.000 37.500 0.000 17 20-0 23/4 253.46 -1.488 37.500 0.040' 0.00 0.000 37.500 0.000 L Interaction:::Desi n Data Corn ression eg .. : g. (... p.. - Section No. Elevation ft Size Ratio P Po Ratio fby F& Ratio fby Fbp Comb. Stress Ratio Allow. Stress Ratio Criteria Tl 130-120 2 0.075 0.245 0.000 0.319 1.333 111-3 1>� 72 120-100 2 0.679 0.046 0.000 0.756 1.333 111-1 y T3 100-80 21/4 0.999 0.044 0.000 1.130 1.333 111-1 T4 80-60 21/2 0.940 0.022 0.000 1.004 1.333 H1.-1 T5 60-40 2 1/2 1.148 0.037 0.000 1.311 Y 1.333 HI T6 40-20 23/4 0.995 0.058 0.000 1.082 1.333 -1 H1-1 T7 20-0 23/4 1.142 0.040 0.000 1.333 X 1.333 Hl -1 x .......... _ .:: ..:..._.................Dgal:=Design Data Compression) Ratio Section Elevation Size L L. K11r F. A Actual Allow. No. P Pa p ft ft ft ksi in' lb lb pa Tl 130-120 1 ?x2xl/4 8.00 3.90 119.5 10.347 0.9380 -1070.60 9705.78 0.110 K=1.00 T2 120-106 L2x2x1/4 8.00 3.90 119.5 10.347 0.9380 -2855.46 9705.78 0.294 K=1.00 T3 100-80 L2x2xl/4 8.00 3.88 119.1 10.406 0.9380 -3890.54 9760.59 0.399 K=1.00 T4 80-60 L2x2x1/4 8.97 4.51 138.4 7.798 0.9380 -2356.43 7314.17 0.322 K=1.00 T5 60-40 L2x2xl/4 10.63 5.33 163.7 5.576 0.9380 -2489.69 5230.13 0.476 �A.c�rrrJresston) - I�Ui1�i' Section Elevation Size L Job Ratio - Allow. N°. Pagc Pagr��� Elevation Size Ratio Ratio Ratio SX06534A SA 534 HWY 99 & WILSON Allow. No. 25 of 3C. 24 of p fb, GPD GROUP Stress Project KUR> 250 (C) - 166 4 ft Po Date Fb, �- Ratio 520SOUTHMAINST. 130-120 L2x2xl/4 0.110 0.006 2006094.42 .0.129 Vr 1.333 15:22:58 07/' Date 120-100 L.2x2xl/4 0.294 0.006 0.024 0.317 i✓ 1.333 H1-3 T3 100-80 L2x2x1/4 0.399 0.009 0.036 0.433 Il✓ AKRON, OH 44311 H1-1 IV� �/ Client 80-60 L2x2xl/4 0.322 0.010 0.040 0.360 1.333 15:22:58 T5 60-40 Phone: 330-572-2100 0.476 0.010 0.038 T -MOBILE USA Hl -1 V T6 Designed by L21/2x21/2xl/4 0.389 0.019 FAX.- 330-572-2102 0.457 1.333 HI -1 V 77 20-0 L3x3xl/4 0.501 0.014 jmcilroy Designed by 1.333 HI -1 Fll-1 jmcilrc Section Elevation Size L L Kl/r F. A Actual Allow. Ratio No. P pa p f ft ft ksi inZ Ib !b Ratic Pa P p K=1.00 lb P T6 40-20 L21/2x21/2x1/4 12.36 6.19 151.2 6.535 1.1900 -3027.68 7776.82 0.389 K=1.00 9.00 1.142 T7 20-0 L3x3xl/4 16.01 8.17 165.6 5.444 1.4400 -3925.58 7839.58 0.501 K=1.00 _ .: Diagonal .411711 Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio to No. M. A, Fb, f& My fby Fb y fby ft Ib ft ksi ksi -TT lb ft ksi ksi Fb, T1 130-120 L2x2x1/4 4.98 -0.143 23.760 0.006 5.48 -0.306 23.760 0.013 T2 120-100 L2x2xl/4 4.91 -0.151 23.760 0.006 -6.65 =0.579 23.760 0.024 1 T3 100-80 L.2x2xl/4 -6.33 -0.204 23.760 0.009 -10.19 -0.865 23.760 0.036 T4 80-60 L2x2xl/4 -7.36 -0.234 23.760 0.010 -11.21 -0.960 23.760 0.040 T5 60-40 L.2x2xl/4 -7.61 -0.236 23.760 0.010 -10.56 -0.908 23.760 0.038 T6 40-20 L2 1/2x2 1/2x1/4 23.61 -0.450 23.760 0.019 31.18 -1.665 23.760 0.070 T7 20-0 L3x3xl/4 -21.04 -0.299 21.600 0.014 -36.95 -1.364 21.600 0.063 �A.c�rrrJresston) - - lu;iagvnai inter..action uesrgn u'ata Section Elevation Size L Section Ratio L. Kl/r F. A Actual Allow. N°. Criteria Elevation Size Ratio Ratio Ratio Comb. Allow. No. T7 20-0 L2 1/2x2 1/2xl/4 13.45 13.22 323.0 1.431 1.1900 -159.38 p fb, fby Stress Stress KUR> 250 (C) - 166 4 ft Po Fb. Fb, Ratio Ratio T1 130-120 L2x2xl/4 0.110 0.006 0.013 .0.129 Vr 1.333 V _ 72 120-100 L.2x2xl/4 0.294 0.006 0.024 0.317 i✓ 1.333 H1-3 T3 100-80 L2x2x1/4 0.399 0.009 0.036 0.433 Il✓ 1.333 H1-1 IV� �/ T4 80-60 L2x2xl/4 0.322 0.010 0.040 0.360 1.333 HI -1 V T5 60-40 L2x2xl/4 0.476 0.010 0.038 -ice 0.514 y 1.333 Hl -1 V T6 40-20 L21/2x21/2xl/4 0.389 0.019 0.070 0.457 1.333 HI -1 V 77 20-0 L3x3xl/4 0.501 0.014 0.063 0.562 1� 1.333 HI -1 Fll-1 �A.c�rrrJresston) Section Elevation Size L Ratio L. Kl/r F. A Actual Allow. N°. io ft P P. P f f ksi in' Ib lb pa T7 20-0 L2 1/2x2 1/2xl/4 13.45 13.22 323.0 1.431 1.1900 -159.38 1703.35 0.094 0 K=1.00 KUR> 250 (C) - 166 4 F- -1 r-1 ERITA"wer Size Actual Page Allow. SX06534A SA 534 HWY 99 & WILSON 26 of 30 GPD GROUP Project Date 520SOU7HMArNST 2006094.42 15:22:58 07/17/06. AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA fby FAX.- 330-572-2102 lb -ft jmcilroy Seconda Horizontaa Bending De ign Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. M� fb, F& fby - My fby Fbr fby ft lb -ft ksi ksi F, lb ft ksi ksi Fb, T7 20-0 L2 1/2x2 (/2x1/4 -107.98 -1.944 23.760 0.082 -102.15 -3.569 23.760 0.150 Secondary Horzontaa Interaction Design Da#a._.... Section . Elevation Size Ratio Ratio Ratio Comb. Allow. Criteria No. P A. fby Stress Stress ft Pa Fbx Fby Ratio Ratio T7 20-0 L2 1/2x2 1/2x1/4 0.094 0.082 , 0.150 0.326 '✓ 1.333 H161/ -3 .Top Girt Design Data. Com .r1. essi.on p Section Elevation Size L L. Kl/r F. A Actual . Allow. Ratio No. ft Pa Pb. Fb, Ratio Section P P. P ft ft ft ksi in' lb lb Po Tl 130-120 L2x2xl/4 _ 6.25 6.08 186.7 4.284 0.9380 -26.10 4018.48 0.006 LZx2x1/4 -18.26 -0.526 23.760 0.022 -18.26 -1.007 K=1.00 0.042 T4 80-60 L2x2xl/4 -18.76 -0.540 23.760 0.023 -17.75 T4 80-60 L2x2x1/4 6.25 6.06 186.1 4.314 0.9380 -291.87 4046.15 0.072 K=1.00 DL controls Top Gart Interaction Design Data Section Elevation Size Ratio Ratio Ratio Top Girt ,Bending Design DataNY Allow. Criteria - No. - P f& fby Stress Stress ft Pa Pb. Fb, Ratio Section Elevation Size Actual Actual Allow. Ratio Actual. Actual Allow. No. M fby Fb� fbr My fby Fb, fbr ft lb -ft ksi ksi Fbr . lb ft ksi ksi F& Tl 130-120 LZx2x1/4 -18.26 -0.526 23.760 0.022 -18.26 -1.007 23.760 0.042 T4 80-60 L2x2xl/4 -18.76 -0.540 23.760 0.023 -17.75 -0.979 23.760 0.041 Top Gart Interaction Design Data Section Elevation Size Ratio Ratio Ratio Comb. Allow. Criteria - No. - P f& fby Stress Stress ft Pa Pb. Fb, Ratio Ratio Tl 130-120 L2x2xl/4 0.006 0.022 0.042 0.071' V 1.000 H1-3 4� T4. 80-60 L2x2x1/4 0.072 . 0.023 0.041 0.136 V 1.333 H1-3 V DL controls Page RM,we J SX06534A SA 534 HWY 99 &WILSON 27 of 30 GPD GROUP Project Date 520SOUTHMAINST 2006094.42 15:22:58 07/17/06 AKRON, OH 44311 Client Designed by Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 jmcilroy Tension Checks .... . .._ ._. .:.. i � 1111 Diagonal' Design Data TensionMH i,.... A .. . Leg Bendi.n:.g Design Data;:.: Leg Des gn Data (Tension) ------------------------- Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. M� fbr Fbi fb, Mr A, Fbr fbr Ratio Section Elevation Size L L„ KI/r F. A Actual Allow. No. 626.39 9.570 37.500 0.255 0.00 0.000 37.500 0.000 T2 P P. P 6:777 ft 0.00 ft ft T3 ksi in' lb lb Pa T1 130-120 2 10.00- 5.00 120.0 30.000 3.1416 1177.93 94247.80 0.012 T2 120-100 2 20.00 5.00 120.0 30.000 3.1416 6481.80 94247.80 0.069 T3 100-80 2 1/4 20.00 5.00 106.7 30.000 3.9761 41005.06 119282.00 0.344 T4 80-60 2 1/2 ( 20.03 5.01 96.1 30.000 4.9087 56082.10 147262.00 0.381 T5 60-40 2 1/2 20.03 5.01 96.1 30.000 4.9087 67619.50 147262.00 0.459 T6 40-20 23/4 20.03 5.01 87.4 30.000 5.9396 77790.70 178187.00 0.437 T7 20-0 23/4 20.03 5.20 90.8 30.000 5.9396 82979.50 178187.00 0.466 � 1111 Diagonal' Design Data TensionMH i,.... A .. . Leg Bendi.n:.g Design Data;:.: Tension ------------------------- Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. M� fbr Fbi fb, Mr A, Fbr fbr ft 16 -ft ksi ksi Fb7 lb -ft ksi ksi Fb, Tl 130-1.20 2 626.39 9.570 37.500 0.255 0.00 0.000 37.500 0.000 T2 120-100 2 443.56 6:777 37.500 0.181 0.00 0.000 37.500 0.000 T3 100-80 2 1/4 125.40 1.346 37.500 0.036 0.00 0.000 37.500 0.000 T4 80-60 2 1/2 . = 134.14 1.049. 37.500 0.028 0.00 0.000' 37.500 0.000 T5 60-40 2 1/2 220.77 1.727 37.500 0.046 0.00 0.000 37.500 0.000 T6 40-20 23/4 348.59 2.049 37.500 0.055 0.00 0.000 37.500 0.000 77 20-0 23/4 348.59 2.049 37.500 0.055 • 0.00 0.000 37.500 0.000 i -p :. _... _ ..:. :_ :....._. _-Leg_.inte,raction Design Data (Tension;) ., . Section Elevation Size Ratio Ratio Ratio Comb. Allow. Criteria No. P f& fby Stress Stress f Po Fbr Fb,, Ratio Ratio Tl 130- 120 2 0.012 0.255 0.000 0.268 ' 1.333 H2-1 72 120-100 2 0.069 0.181 0.000 0.249 1.333 H2_1 73 100-80 2 1/4 0.344 0.036 0.000 0.380 1.333 H2-1 T4 80-60 2 1/2 0.381 0.028 0.000 0.409 1.333 H2 -1- 12 1T5 T5 60-40. 2 1/2 0.459 0.046 0.000 0.505 1.333 H2-1 T6 40-20 2 3/4 ..0.437 0.055 0.000 0.491 1.333 H2-1 T7 20-0 23/4 0.466 0.055 0.000 0.520 �+� 1.333 1.12 1 Y � 1111 Diagonal' Design Data TensionMH i,.... A ERITrawer V - SX06534A SA 534 HWY 99 & WILSON GPD GROUP Project 520 SOUTHMAINST 2006094.42 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA FAX.- 330-572-2102 Page 28 of 30 - Date 15:22:58 07/17/06 Designed by jmcilroy Section Elevation Size L L. K11r Fa A Actual Allow. Ratio No. 0.061 0.007 M� fbr Fb. fb. Mr P P. P 0.013 f 0.217 ft ft ksi ksi in' lb lb pa T1 130-120 L2x2x1/4. 8.00. 3.90 76.8 29.000 0.5629 1001.86 16323.40 0.061 T2 120-100 L2x2xl/4 8.00 3.90 76.8 29.000 0.5629 2831.31 16323.40 0.173 T3 100-80 1.2x2x1/4 8.00 3.88 _ 76.5 29.000 0.5629 3759.93 16323.40 0.230 T4 80-60 L2x2x1/4 8.58 4.31 85.0 29.000 0.5629 2306.88 16323.40 0.141 T5 60-40 L2x2xl/4 11.05 5.54 109.2 29.000 0.5629 2448.34 16323.40 0.150 T6 40-20 L2 1/2x2 1/2x1/4 12.36 6.19 96.5 29.000 0.7519 2033.93 21804.40 0.093 T7 20-0 L3x3xl/4 16.77 8.54 110.2 29.000 0.9159 3617.27 26562.20 0.136 Diagonal.Bending.bes Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. 0.061 0.007 M� fbr Fb. fb. Mr fby Fbr fbr 0.013 I t 0.217 Ib ft ksi ksi Fbr lb -ft ksi ksi F, TI 130- 120 L2x2xl/4 6.13 0.177 23.760 0.007 6.94 0.383 23.760 0.016 72 120-100 L2x2xl/4 10.71 0.308 23.760 0.013 13.18 0.727 23.760 0.031 T3 100-80 L2x2xl/4 15.86 0.455 23.760 0.019 19.53 1.077 23.760 0.045 T4 80-60 L2x2x1/4 17.80 0.512 23.760 0.022 20.48 1.129 23.760 0.048 T5 60-40 L2x2xl/4 15.43 0.444 23.760 0.019 17.54 0.968 23.760 0.041 T6 40-20 L2 1/2x2 1/2x1/4 46.14 0.831 23.760 0.035 49.60 1.733 23.760 0.073 77 20-0 L3x3x1/4 42.44 0.524 .23.760 0.022 60.19 1.469 23.760 0.062 is 51Diagonal 4116.611. Data Section No. Elevation ft Size Ratio P Pa Ratio A. F& Ratio Al Fb, Comb. Stress Ratio Allow. Stress Ratio Criteria Tl 130-120 L2x2x1/4 0.061 0.007 0.016 0.085 1.333 H2-1 T2 120-100 L2x2xl/4 0.173 0.013 0.031 0.217 1.333 H2-1 T3 100-80 L2x2xl/4 0.230 0.019 0.045 0.295 1.333 H21 T4 80-60 L2x2x1/4 0.141 0.022 0.048 0.210 Y 1.333 H2-1 T5 60-40 L2x2xl/4 0.150 0.019 0.041 0.209 1.333 142-1 T6 40-20 L2 1/2x2 1/2x1/4 0.093 0.035 0.073 I 0.201 Y 1.333 H2-1 T7 20-0 L3x3xl/4 0.136 0.022 0.062 0.220 < 1.333 H2-1 :..x.. Seconda..:..'Horrzontal..Design Data..:Tension: , ' ....:..:. Ratio Section Elevation Size L Lu ° Kl/r F. A Actual Allow. No. P P. P ft ft ft ksi int lb lb pa T7 20-0 L2 1/2x2 1/2x1/4 12.48 12.25 191.2 21.600 1.1900 13.16 25704.00 0.001 DL controls , ERITower GPD GROUP 520 SOUTH MAIN ST. AKRON, OH 44311 Phone: 330-572-2100 FAX- 330-572-2102 Ir Page SX06534A SA 534 HWY 99 & WILSON 29 of 30 Project Date 2006094.42 15:22:58 07/17/06 Client Designed by T -MOBILE USA jmcilroy Seconds Horizonfa Bendcng Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual' Allow. Ratio No. M: fey Fbrfbz • pa My Jby Fby fby fl lb ft ksi ksi Tb lb -ft ksi ksi Fby T7 20-0 L.21/2x21/2x1/4 -93.07 1.676 23.760 0.071 -88.04 3.108 23.760 0.131 Secondary Hozontal interaction Design .Data Section Elevation Size Ratio Ratio Ratio Comb. Allow. Criteria No P fb. fby Stress Stress ft • pa Fb, Fby Ratio Ratio T7 20-0 L2 1/2x2 1/2x1/4 0.001 0.071 0.131 / 0.201 i+' 1.000 H2-1 DL controls Top _Girt Design .Data (Tension) ... . Section Elevation Size L L„ K11r Fa A Actual Allow. Ratio No. No. fbx M fbr Fbr P Pa P Fby ft ft ft ksi in' lb lb P. Tl 130- 120 L2x2x1/4 6.25 6.08 119.9 21.600 0.9380 48.15 20260.80 0.002 T4 80-60 L2x2xl/4 6.25 6.06 119.5 21.600 0.9380 225.01 20260.80 0.011 Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. fbx M fbr Fbr f& MY Jby Fby fby Fby ft lb ft ksi ksi _Tb lb ft ksi ksi Fby T1 130-120 L2x2xl/4 -18.26 0.526 23.760 0.022 -18.26 1.019 23.760 0.043 T4 80-60 L2x2xl/4 -18.76 0.540 23.760 0.023 -17.75 0.990 23.760 0.042 ToGirt Interaction Desa n Data _:... _ .....: pl- ............... ..:.. _ ._ . g.... Section Elevation Size Ratio Ratio Ratio Comb. AHow. Criteria No. P fbx fby Stress Stress ft Pa Fby Fby Ratio Ratio Tl 130-120. L2x2xl/4 0.002 0.022 0.043 0.067 J.331 H2-1 T4 80-60 L2x2x1/4 0.011 0.023 0.0420.075 1.333 H2 1 �% 0 Job - - Page ERITaw�� SX06534A SA 534 HWY 99 & WILSON 30 of 30 GPD GROUP Project Date 510 SOUTH MAIN ST. 2006094.42 15:22:580711 7106 AKRON, OH 44311 Client Phone: 330-572-2100 T -MOBILE USA Designedby FAX.- 330-572-1102. jrnalroy Section Elevation Component Size Critical P SF*p 11.. % Pass No. It Type Element lb lb Capacity Fail Tl 130-120 Leg 2 1 -2432.72 43427.94 23.9 Pass Diagonal L2x2xl/4 7 -1070.60 12937.80 9.7 Pass Top Girt L2x2xl/4 4 -26.10 4018.48 12.5 (b) 7.1 Pass T2 120-100 Leg 2 19 -22116.70 43427.94 56.7 Pass Diagonal L2x2xl/4 22 -2855.46 12937.80 23.8 Pass T3 100-80 Leg 21/4 46 -52140.30 69560.47 33.3 (b) 84.8 Pass Diagonal L2x2x1/4 49 -3890.54 13010.87 32.5 Pass T4 80-60 Leg 2 1/2 73 -71921.50 101979.16 45.5 (b) 75.3 Pass Diagonal L2x2x1/4 86 -2356.43 9749.79 27.0 Pass Top Girt L2x2x1/4 77 -291.87 5393.52 28.5 (b) 10.2 Pass T5 60-40 Leg 2 1/2 103 -87794.80 101979.16 98.4 Pass Diagonal L2x2x1/4 113 -2489.69 6971.76 38.6 Pass T6 40-20 Leg 23/4 130 -103336.00 138480.03 81.2 Pass Diagonal L21/2x21/2x1/4 139 -3027.68 10366.50 34.3 Pass T7 20-0 Leg 23/4 159 -113755.00 132792.12 35.8 (b) 100.0 Fail x ,Diagonal L3x3x1/4 170 -3925.58 10450.16 42.1 Pass Secondary Horizontal I.21/2x21/2x1/4 166 -159.38 2270.57 24.4 Pass. Summary Leg (T7) 100.0 Fail)( Diagonal 45.5 Pass (T3) Secondary 24.4 Pass Horizontal (T7) Top Girt 10.2 Pass (T4) Bolt Checks 45.5 Pass RATING = 100.0 Fail k Program Version 3.0.0.16 - 7/8/2004 File:C:/Documents and Settings/jmcitroy/Desktop/wilson/eri/wilson.eri 9=■ 100.0 ft 60.0 ft 20.0 ft 0.0 ft • APPI IRTFMANrPQ TYPE 20' Omni ELEVATION 140 TYPE SD98 ELEVATION 20' Omni 140 I SD98 I 113 (4) RR6S19.00DP 123 NextNet BTS -2500 113 (4) RR65-79-OODP 123 NeuWet 25W 173 1 Pirod Pirod T -Frame Sector Mount (3) 123 'NexWet STS -2500 1173 (4 RR6S79-0ODP 123 NexWet BT -2500 1113 Pirod T•Frame Sector Mount (3) 1131110 SD98 SD98 713 HP2.23 110 110 SD98 113 4 F DISH 100 MATERIAL STRENGTH GRADE F Fu GRADE F Fu A572.50 50 ksi 65 ksi A36 36 ksi 58 ksi 1 TOWER DESIGN NOTES 1. Tower is located in Butte County, California. 2. Tower designed for a 75 mph basic wind in accordance with the TIA/EIA-222-F Standard. 3. Tower is also designed for a 65 mph basic wind with 0.50 in ice. 4. Deflections are based upon a 50 mph wind. 5. TOWER RATING: 100% IN MAX PIER FORCES: DOWN: 118990 Ib UPLIFT.- -891031b SHEAR: 9735 Ib AXIAL 27435 Ib SHEAR MOMENT 1671116 zi 1326388 Ib -ft TORQUE 7217 lb -ft 65 mph WIND - 0.5000 in ICE AXIAL 17244 Ib MOMENT SHEAR1171841 Ib -ft 14536 Ib Z� TORQUE 5627 Ib -ft REACTIONS - 75 mph WIND %GPD GROUP 0 520 SOUTH MAIN ST. PDGROUP AKRON, OH 44311 Phone: 330-572-2100 obi SX06534A SA 534 HWY 99 & WILSO Pr°'�" 2006094.42 cBent T -MOBILE US D'a"n bY'mcilro 4pd: c°de' TIAIEIA-222-F Date' 07/17/06 JSZaie: NTS �. • Feedline PI� Round Flat App In Face App Out Face F Fu y 58 ksi the TIA/EIA-222-F Standard. ice. �'Vy 8'VLSO r. ima,9 f+pp'd: h O�� SOF tib, GPD GROUP lob: SX06534A. SA 53- 0 SOUTH MAIN ST. ®ems 521-31 2ooro9a.a2 0 PO GROUP AKRON, OH 44311 client T,MOBILE US Date Phone: 330-572-2100 Code: TIA/EIA-222-F FAX: 330-572-2102 Path . c-.�a • Seismic Calculations (1997 UBC) Site Name Site Number GPD Job Number Tower Type Structure Height (ft) City State County Seismic Zone Soil Profile Type Importance Factor (1) R f% Z C„ N„ Ca Na Tcalc Tmax T g (ft/sec2) Seismic Source Type Proximity to Nearest Seismic Event Weight of Structure (kips) Ft Vcalc Vmax Vmin1 Vmin2 Base Shear V (kips) Tower Component Section 7 (top) Section 6 Section 5 Section 4 Section 3 Section 2 Section 1 (bottom) Antennas @ 130' Antennas @ 123' Antennas @ 113' Dishes @ 110' Dish @ 100' Ft OTM from Seismic Loading OTM from Wind Loading Wind Loading Controls SA534 Hwy 99 & Wilson SC06534A 2006094.42 Self Support 130 . Chico 'Califonia Butte 3. ::.SD (UBC Table 16-J) 1.00, (UBC Table 16-K) .2 90• (UBC Table 16-P) 2.00 (UBC Table 16-P) .0.36.(UBC Table 16-I) 0.54 (UBC Table 16-R) 9.00' (UBC Table 16 T) 0.36 (UBC Table 16-Q) 1.00: (UBC Table 16-S) 1.64 1.08 (UBC Section 1630.2.2.2) 1.08 32.20 B (UBC Table 16-U) "assumed > 15 KM "assumed 14.279 0.186 (UBC Equation 30-14) 2.466 (UBC Equation 304) 4.431 (UBC Equation 30-5) 2.879 (UBC Equation 34-2) 0.166 (UBC Equation 34-3) 2.879 Weight (k) M. Arm (ft) F. w. -h. F.*M.A. 0.722` ::.' . '.::125: 0.2638 90.188 32.97 •1.317. :; .:' ' ;. ". 110` 0.4237 144.870 46.60 1:496 _., .,,; ;90 0.3938 134.640 35.44 >> 1.823:':`x:: -'',"70 0.3732 127.610 26.12 .1.892-.: ;. 50 0.2767 94.600 13.83 2.513.:`;.;.'::.,.. ' 30 0.2205 75.390 6.61 2.618 :. ".:. 10 0.0766 26.180 0.77 0.100 ": , ;;.:., 130 0.0380 13.000 4.94 ;::1.336 ", ";,' • ;.: .. 123 0.4806 164.328 59.11 0.238': ,: i.. •;" 113 0.0787 26.894 8.89 =:0.054.: :`_ . 110 0.0174 5.940 1.91 0:170 - 1000.0497 17.000 4.97 n/a ' < : 124 0.1861 n/a 23.08 14.279 920.64 265.25 265.25 k'ft 1326.39 k'ft Connections Elevation (ft) 0-20 20-40 40-60 60-80 80 - 100 100 - 120 120 - 130 f; (k) 0.077 0.220 0.277 0.373 0.394 0.424 0.264 6; (in) 0.011 0.078 .,' ..0.207 0.404 -,0.673 0.999 1.253 wd? , 0.000 0.015 0.081 0.297 0.678` 1.314 1.133 f;•6; 0.001 0.017 0.057 0.151 0.265 0.423 0.331 Leg Forces (seismic)(k) 14.55 12.77 10.63 8.48 6.00 2.28 0.07 Leg Forces (Seismic factored by Q)(k) 29.10 25.54 21.26 16.96 12.00 4.56 0.14 Leg Forces (wind)(k) 113.755 103.336 87.794 71.921 52.14 22.116 2.432 Controlling Force Wind Wind Wind Wind Wind Wind Wind Diagonal Forces (seismic)(k) 0.62 0.53 0.45 .'.0.41 0.65 0.43 0.11 Diagonal Forces (Seismic factored by 0)(k) 1.24 1.06 0.90 0.82 1.30 0.86 0.22 Diagonal Forces (wind)(k) 3.925 3.027 2.489 2.356 3.890 2.855 1.070 Controlling Force Wind Wind Wind Wind Wind Wind Wind Fw;•8 2 1.071 Ef;•b; 0.491 David Wiltsee Planning Consultant Epic Wireless/Clearwire LLC 381 South Lexington Drive, Suite 103 Folsom, CA 95630 August 17, 2006 U N T Y AUG Z 12006 Mr. Chris Thomas DEVELOPMENT Butte County Development Services Department SERVICES 7 County Center Drive Oroville, CA 95965 Subject: RF/EMF Study for CA-CHCO11 West East Avenue (Use Permit) Dear Chris: Enclosed is the RF/EMF Study (EBI 61063526, August 10, 2006) for the Clearwire Use Permit application submitted yesterday, August 16. I would appreciate having this document added to the City's project file. The project is a collocation on an existing tower on West East Avenue. I believe inclusion of this document in the file makes the application complete and ready for processing. Thanks, Chris. ours truly, 'I Dave Wiltsee dwiltsee@sbcglobal.net Encl: Radio Frequency Emissions Compliance ReportCA-CHC-011 (EBI 61063526, August 19, 2006) f' • ` V i•m a«•.l mm xa• i iw+w wr EBIC 0 N S U L T I rG National Environmental Management and Engineering Services EBI Consulting Four A Street Burlington, MA 01803 Phone: 781.273.2500 Toll Free: 800.786.2346 Fax: 781.273.331 1 RADIOFREQUENCY EMISSIONS COMPLIANCE REPORT CA-CHC01 I EASTA VENT -MOBILE. CHICO, CA EBI PROJECT 61063526 August 10, 2006 Prepared for: - CLEARWIRE CORPORATION r EBI CONSULTING FOUR A STREET BURLINGTON, MAO 1803 800-786-2346 PROJECT #61063526 RADIOFREQUENCY EMISSIONS COMPLIANCE REPORT CA-CHCD/ / EASTA VENT-MOB/LE CH/CO, CA August 10, 2006 Prepared for.- Clearwire Corporation and Epic Wireless Group . S, 7£ a .«..?��Srxt" .i+p+'' .Ez;d E a. �,'3 tik' F ;, k � ��` � �jj�'�P" �1;• rp-:'<a } '$'� Z -) Q�' � � .. Four A Street Ya - E n�.EBI Burlington, MA 01803 C0NSU LTI'N,G Tel: 7812732500 www.ebiconsuIting.com Fax: 781,273,331 August 10, 2006 Mr. Bryon Sattler ClearWire Corporation do Epic Wireless Group 381 S. Lexington Drive, Suite 103 Folsom, CA 95630 Subject: -Radiofrequency Emissions Compliance Report East Ave/T-Mobile, Chico (CA-CHC011) I 1 I0 W. East Road, Chico California 95926 EBI Project #61063526 Dear Mr. Sattler: Attached, please find our RAD/OFREQUENCYEM/SS/DNS COMPL/ANCEREPORT, (the Report] for the proposed telecommunications installation at the address noted above (the Subject Property). The purpose of this Report is to evaluate the 'a bove -referenced property for radiofrequency emissions compliance requirements as specified by the FederalCommunications Commission (FCC) and' Butte County Zoning Code 24-262 and general industry standards. The Report was completed according to the terms and conditions authorized by you. There are no intended or unintended third party, beneficiaries to this Report; unless specifically named. EBI is an independent contractor, not an employee of either the property owner or the project proponent, and its compensation was not based on the findings or recommendations made in the Report or on the closing of any business transaction. Thank you for the opportunity to prepare this Repor•4 and assist you with this project. Please call us if you have any questions or if we may be of further assistance. . Respectfully Submitted, „ Mr. Richard Beauregard Mr. Kevin McManus .: Ms. Julia Jongsma RF -EHE Plan Preparer RF-EME Program Director Program Manager (617) 715-1823 (617) 715-1835 (206) 774-8473 APPENDIX A: Site Questionnaire for Proposed Clearwire Corporation Telecommunications Equipment APPENDIX B: Site Plans APPENDIX C: Other RF Emissions Sources in Vicinity of Project Site APPENDIX D: RoofView® Export Files Radiofrequency Emissions Compliance Report CA-CHCO/ l ///0 W. East Road, Chico, CA TABLE OF CONTENTS Page I. INTRODUCTION 2 II. PROJECT DESCRIPTION 3 III. SITE DESCRIPTION 4 IV. FCC RADIOFREQUENCY EMISSIONS REQUIREMENTS 4 V. EMISSIONS COMPLIANCE EVALUATION FOR CLEARWIRE AND OTHER CO -LOCATED CARRIERS 5 VI. EMISSIONS FROM OTHER SOURCES (LOCATED WITHIN 2,000 FEET OF PROJECT SITE) 7 VII. SUMMARY AND CONCLUSIONS 8 VIII. LIMITATIONS 9 IX. REFERENCES 10 APPENDIX A: Site Questionnaire for Proposed Clearwire Corporation Telecommunications Equipment APPENDIX B: Site Plans APPENDIX C: Other RF Emissions Sources in Vicinity of Project Site APPENDIX D: RoofView® Export Files Radiofregiuency Emissions Comp/lance Report CA-CHC011 • ///0 W. East Road, Chico, CA I. INTRODUCTION EBI CONSULTING (EBI) has prepared this Radiofrequency Emissions Compliance Report Radiofrequency Emissions Compliance Report on behalf of Clearwire, Inc. for the proposed installation, of telecommunications equipment at an existing lattice tower located on 1110 East Avenue, Chico, California. The Butte County Zoning Code 24-262 requires the preparation of a report by a qualified radiofrequency engineer stating the maximum radiofrequency radiation to be emitted by the project, and an evaluation of compliance with Federal . Communications Commission (FCC) safety standards. The conclusions provided by EBI are based solely on the information obtained by file review at the Butte County planning office, information obtained from the agencies noted in the Report, and information provided by the Client. It is our understanding that this Report is to be used and distributed exclusively for purposes connected with the permitting for telecommunications site construction and operation. This Report may be relied upon by others, as authorized by EBI in writing, subject to the limitations set forth in this document and other referenced documents. EBI Consulting 2 Radiofrequency Emissions Compliance Report C.4-CHCO/ / ///0 W. East Road, Chico, CA 11. PROJECT DESCRIPTION This project involves the addition of three (4) panel antennas and four (5) microwave dish antennas and associated equipment by Clearwire Corporation to an existing cellular communications tower facility located at I 110 East Avenue in Chico, California. Butte County Zoning Code 24-262 requires a report by a qualified radiofrdquency engineer stating the maximum radiofrequency radiation to be emitted by the facility and demonstrating that the proposed equipment will confirm to FCC safety standards (as stated in FCC OET Technical Bulletin 65 (1997) titled, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic field.'). For this analysis, EBI Consulting has utilized several sources of information regarding the• existing and proposed telecommunications equipment, for the facility. This includes a consultation and a file. review with the Butte County Planning Department, review of previous RF-EME compliance reports submitted for the site, theoretical worst-case modeling for both the panel antennas and microwave dish antennas, and assessment of other license holders within 2,000 feet of the facility. EBI Consulting 3 Radiofrequency Emissions Compliance Report C4*Co/ / ///0 W. East Road, Chico, C.4 III. SITE DESCRIPTION The proposed equipment will be installed at an existing lattice tower site located at I 110 East Avenue in Chico, California. An existing 130 -foot tall lattice tower and associated telecommunications equipment shelters and utilities are located behind (to the north) the Masonic Temple at the western side of the property. The tower is owned by T -Mobile, and T - Mobile is currently operating panel and microwave antennas at the site. The existing panel and microwave antennas are located at an approximate height of 120 and 125 feet respectively, above ground level. ClearWire Corporation is proposing to mount four panel antennas at a centerline height of 106 feet above grade and four microwave dishes at a centerline height of 110 feet above grade. The locations and configuration of equipment proposed by ClearWire Corporation, as well as existing site equipment, are shown in Appendix B (Site Plans). IV. FCC RADIOFREQUENCY EMISSIONS REQUIREMENTS Radiofrequency energy, a form of non -ionizing electromagnetic energy (RF EME), is emitted from telecommunications antennas. Under certain conditions, human exposure to radiofrequency energy can cause partial body heating. The Federal Communications Commission (FCC) has developed maximum permissible exposure limits (MPE) that help identify risks associated with human exposure to radiofrequency energy. First,;the occupational, or controlled MPE, applies to individuals who may come into contact with radiofrequency energy as a consequence of their employment, but have been made fully aware of the potential for exposure and have the ability to exercise control over the exposure.:Second, applies to the exposure the general public may experience, and they are generally unaware of the potential for exposure. The FCC's MPEs are measured in terms of the power that emits through the antenna, (power density) extending over a surface area. These MPEs vary with the frequency of the emitted RF energy, as shown below in Figure I. Cellular/PCS frequencies typically range from 800 megahertz (MHz) to 2.5 gigahertz (GHz). Microwave frequencies typically utilize higher frequencies, ranging up to 50 GHz. For the equipment evaluated within this analysis, the FCC's most stringent limit for uncontrolled/general population is I mw/cm' (based upon the T -Mobile equipment that is assumed to be operating at a frequency of 1900 MHz). As the focus of this report is on the potential impacts to the general public outside the controlled areas of the facility, EBI has evaluated compliance relative to the FCC's uncontrolled MPE limit. EBI Consulting Sr rf Of 56 AJ Pq-Z2PAi 4 Radiofrequency Emissions Compliance Report CA-CHCOI l ///0 W. East Road, Chico, CA Figure f_ FCC Limits for h4aximum Permissible Exposure (MPE) Piane4vave Eqi ivaient Power Density .WU ccupaiibnah ContraRedExposure —---nGenera.'Pape lar a n.Vn=niroikd =rposu.-c- .._...-—,. .,. ___,........_._...... _ 1. l A i 0.1 0.03 0.3 i .3 3.' 30' t 3.DM 30.000 j 307..00, 1.34 1.500 Frequency (M Hz) Source: Federal Communications Commission, Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic fields, OET Bulletin 65, Edition 97-0/, August 1997, p. 68 The FCC has established several different methods for determining the power density emitted from an antenna. For the purposes of this safety plan, EBI has utilized theoretical models to estimate power density. The FCC recognizes that these theoretical models over-estimate the actual exposure one would experience and generally considers the results to represent a worst- case exposure scenario. The actual power density is expected to be much less because the antennas do not operate continuously at full power. V. EMISSIONS COMPLIANCE EVALUATION FOR CLEARWIRE CORPORATION AND CO -LOCATED CARRIERS To assess the cumulative RF impacts of the proposed ClearWire equipment and other co -located carriers from the site, EBI has compiled available antenna operational specifications from previous report submittals and run a RoofView® analysis to predict worst-case RF emissions fields at the nearest property boundary. RoofView® is a widely -used predictive modeling package that has been developed by Richard Tell Associates to predict both near field and far field RF power density values for roof -top and tower telecommunications sites produced by vertical collinear antennas that are typically used in the cellular, PCS, paging and other communications services. The model utilizes several operational specifications for different types of antennas to produce a EBI Consulting 5 Radiofrequencyons Comp/lance R A-HCO11 Eml'ssl' Report ///0 W East Road, Chico, CA plot of spatial ly-averaged power'densities that can be expressed as a percentage of the applicable exposure limit. For this -report,' EBI utilized the FCC's general exposure limits outlined in OET 7 Bulletin 65. NOTE- EN retained Richard, Tell Associates to provide technical support- services in modeling andevaluating compliance with FCC and municipal requirements. X t a To augment this analysis, EBI has also conducted a.separate evaluation the RF emissions fields resulting from the microwave. dishes. These antennas must be evaluated separately because RoofView@ is designed to address. impacts from vertical collinear, and cannot be used for microwave dish configurations. The. table below outlines the specifications for the proposed ClearWire equipment and other carriers' equipment utilized for the RoofView@ analysis. Where information is incomplete or inconsistent with previous reports filed for the site, EBI has utilized worst-case. conservative assumptions to maximize the predicted RF fields resulting from the model runs as indicated bya" table footnote. I Conservative assumption based upon technical knowledge In addition to the information presented above, the following conservative assumptions were used for RoofView@ modeling:. • All antennas on the tower. Were placed at the same location (given the same X,Y .Coordinates); • For existing carriers with multiple antennas per sector, it was assumed that,all of the power for the sector would transmit from one antenna., The antennas for the existing carriers are oriented in the same directions as the ClearWire Corporation antennas. EBI,.- Consulting 6 A 67 na GenNe-41r7h s w 4` degr.., ClearWire 2500- 50 1 90/3 108 Corporation 2686 T -Mobile 1900 1001-71 1 65/61 119 (approx.) T -Mo He 1900 1001 1 , I Omni/101 135 (approx.) I Conservative assumption based upon technical knowledge In addition to the information presented above, the following conservative assumptions were used for RoofView@ modeling:. • All antennas on the tower. Were placed at the same location (given the same X,Y .Coordinates); • For existing carriers with multiple antennas per sector, it was assumed that,all of the power for the sector would transmit from one antenna., The antennas for the existing carriers are oriented in the same directions as the ClearWire Corporation antennas. EBI,.- Consulting 6 Radiofrequency Emissions Comp/lance Report CA-CHCO/ / ///0 W. East Road, Chico, CA RESULTS The RoofView® Modeling results indicate that the worst-case emitted power density from the combined impacts from Clearwire's proposed equipment, together with that of existing carriers on the site, will not exceed the FCC's general exposure limits at ground level in any uncontrolled areas. At ' ground level, worst-case power densities at the closest property boundary are estimated at 0.0021 mW/cm2, or 0.211 % of the FCC's uncontrolled limits. (MPE= I mW/cm2 derived from the FCC calculation utilizing the lowest estimated frequency onsite of 1900MHz) The RF fields associated with the microwave antennas were calculated separately (see Appendix -D). The power density from the microwave antennas were conservatively estimated using a. methodology developed by Richard Tell Associates and presented in "Summary of Near Field Power Density Calculations for EN Consu/tind,'. At ground level, worst-case power densities from the microwave antennas are estimated to be 0.0016 mW/cm2, or 0.164% of the FCC's uncontrolled limits. Please note that this is a conservative estimate of power density as the equations for near field . exposures were used in the calculations. It is likely that any public exposure would be beyond this near field region. Generally, beyond the near field region of microwave dish antennas, power density decreases inversely with distance, or inversely with the square of distance, depending upon the distance(s) under evaluation. As such, the power density beyond the near field region would likely be significantly less than the predicted value. VI. . EMISSIONS FROM OTHER SOURCES (WITHIN 2,000 FEET OF PROJECT SITE) EBI has conducted a review .of the FCC's database to determine the location of licensed telecommunications facilities within 2,000 feet of the project site. Our review indicates that there is one a c1 ' e vicinity, ut it is located beyond 2,000 feet from the project site (See p7 ppenaiZ-CT—Tt shou be note that the FCC database is likely to be incomplete for many telecommunications sites, due to (a) the regional nature of cellular/PCS license authorizations, which can generate antenna/equipment installations that are not reported for this database; and (b) the FCC reporting thresholds which exempt many categories of facilities. However, the associated RF emissions fields associated with these unlisted sources would be attenuated very rapidly with increasing distances, and the height above ground for these structures. As a result, cumulative ground -level impacts from these sources, operating concurrently with the equipment at the Estes Drive site, are expected to be well below the FCC's general exposure guidelines. P�1 Gr vs. ,h�E u 0.0((07o luL '4 �SSi✓or`1 S Fes"" 6Tee"k sty s EBI Consulting 7 Radiofrequency Emissions Compliance Report CA-CHCOI l / / /0 W. East Road, Chico, CA VII. SUMMARY AND CONCLUSIONS In accordance with the Butte County Zoning Code 24-262, EBI has prepared a Radiofrequency Emissions Compliance Report for the proposed telecommunications equipment to be installed by Clearwire Corporation on an. existing self-support lattice tower located at I 110 East Avenue in Chico, California. EBI has performed a review of existing and proposed equipment and conducted theoretical modeling to estimate the worst-case power density from each antenna. Our findings regarding the Subject Site are as follows: I. The worst-case emitted power density from the combined impacts from Clearwire's proposed equipment, operating concurrently with that of existing carriers on the site, will not exceed the FCC's general exposure limits at ground level in any uncontrolled areas. At ground level, worst-case power densities at the closest property boundary are estimated at 0.0037 mW/cm', or 0.375% 'of the FCC's uncontrolled limits. Members of the general public will continue to be restricted from areas where potential exceedances can be found (on the tower, directly in front of antenna faces), by site control and access restrictions. 2.. The only potential exceedances of FCC's limits are for occupational exposures to telecommunications workers conducting work on the monopole. .The power densities will also not exceed FCC occupational exposure limits in the center of the tower but may exceed the FCC's occupational limit directly in front of the antenna faces. Workers involved in tower operation and maintenance activities are typically provided detailed RF - safety training; they follow detailed standard operating procedures (SOPS), including the use of personal RF monitors, antenna lockout-tagout protocols, and limits on the time of exposures in front of active antennas, to ensure compliance with the FCC's occupational exposure limits. 3. There are no significant cumulative, ground -level impacts from other known RF emissions sources located within 2,000 feet of the facility, due to the rapid attenuation of RF power density fields associated with the proposed and existing equipment, and the distances of the nearest FCC licensed facilities. EBI Consulting 8 Radiofrequency Emissions Compliance Report CAO/ l • ///0 W. East Road, Chico, CA VIII. LIMITATIONS This Report was prepared for the use of ClearWire Corporation. It was performed in accordance with generally accepted practices of other consultants undertaking similar studies at the same time and in the same locale under like circumstances. The conclusions provided by EBI are based solely on the information obtained by visual inspection of the. Subject Property, information obtained from the agencies noted in the Report, and information provided by the client. The observations in this Reportare valid on the date of the investigation. Any additional information that becomes available concerning the Subject Property should be provided to EBI so that our conclusions may be revised and modified, if necessary., This .Report has been prepared in accordance with Standard Conditions For Engagement and authorized proposal,- both of which are integral parts of this Report. No other warranty, expressed or implied, is made. EBI Consulting 9 1 • Radiofrequency Emissions Compliance Report • CA-CHCO/ / ///0 W. East Road, Chico, CA IX. REFERENCES Federal Communications Commission, Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields OET Bulletin 65, Edition 97-01, August 1997, p. 68 Richard Tell and Associates. Summary ofNearFeld Power Density Calculations for EB/ Consulting. July 21, 2006 EBI Consulting 10 • Radiofrequency Emissions Compliance Report • CA-CHCOI l East Avenue/T-Mobile, Chico, CA 0 APPENDIX A Site Questionnaire for Proposed Clearwire Telecommunications Equipment EBI Consulting 11 Radiofrequency Emissions Coiance Report CA-CH•l East Avenue/T-Mobile, Chico, CA RF-EME Site Compliance Questionnaire CA-CHC01 1-1110 East Avenue/T-Mobile, Chico CA EBI Consulting 12 Site Data I . Antenna Latitude (or UTM 39-44-45.5 coordinate) 2. Antenna Longitude '(or UTM 121-52-56.1 coordinate) 3. Location (City, State, Zip) Chico, CA 95926 4. Maximum Design RF EME Output per 50W . Sector (Watts or dBM) 5. Frequency (MHz) 2500-2686 mHz 6. Antenna Gain (dB) 17 db 7. Total Line Loss from all components ? (assume 1.5) 8. Type of Antenna Feed line and size 7/8" LDF (diameter) of coaxial cable 9. Type of Antenna 4- Stella Doradus #26SD9890 Microwave Orthogon OS Gemini Lite 5.8 GHz Orthogon OS Gemini Lite 5.8 GHz Dragonwave 24 GHz Dra onwave 24 GHz 10. # of Transmitters per Sector, I I I~# of operating antennas to be 4 panel antennas & 4 MW dishes modeled 12. Other Carriers/Equipment on Site?. I. T -Mobile (specify if known) 13. Antenna Height above Ground or 4 panel antennas @ 110' & 4 MW Roof Level? dishes 106'. (specify height from ground or roof to base of antenna) EBI Consulting 12 Radiofrequency Emissions Compliance Report CA-CHCOI l East Avenue/T-Mobile, Chico, CA APPENDIX B SITE PLANS EBI Consulting 13 0 EASTAVE. �cIN'n 'P ® clearWre♦ 3 T -MOBILE � I SITEPACIFIC TELECOM CA-CHC011 1 1 • GAZLEY n PLOWMAN) N Pot Mn YwaM ARCHITECTS m swl. 7e. PROJECT DESCRIPTION 9 ( )� 9 P P>1m.e, a. 47x1a Z:\Cleamire\Drowings\PTS\2005\05255 Drawin s PTS 2005 05255 CA—CHC011 East Ave — 7— Mobile Dw s CD CA—CHCOt 1 MAP.bm eo.T 2 . im3 FO- O m b C CLEARWIRE (CW) PROPOSES TO APPEND A14 EXISTING CELLULAR FACILITY BY THE AObIT10N! OF (9) ANTENNAS (FOUR (4) PANEL 8'. FIVE (5) MICROWAVE) TO AN E%ISTItJC LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNA S ANDA SITE SUPPORT CABINET NEAR ME BASE OF THE SAME TOWER. SITE INFORMATION PROJECT CONTACTS I N SITE ADDRESS: 1110 W. EAST ROAD GENERAL CONTACT: LONNIE GUIN n CHICO. CA. 95926 CLEARWIRE W 5508 LAKE WASHINGTON BLVD. 0 KIRKLAND. WA 98033 N (425)216-7821 PARCEL NUMBER: 042-07G-197 FAX (425) 216-7900 O W LATITUDE: ,39' 44' 45.5' N SITE DESIGN: STEVE ISHIHARA o PACIFIC TELECOM SERVICES n a rc`� LONGITUDE: 464-4412DE: 121' 52' 56.1" B FAX (206) 903-8513 DRIVING DIRECTIONS DRAWING INDEX $ISHIHARAmPTSWA.COM a LAT/LWIG TYPE: NAD 83 = W( 1 U -FROM REOOINC, MERGE ONTO 1=5 (SOUTH) Y SITE CONTACT: DAN OUTTON 3 $ 0 ELEVATION: 167' LEGACY WIRELESS SERVICES -TAKE THE CA-99/CA-36EXIT TOWARD CHICO/ SHEET CONTENTS (503) 658-5300 LAUREN PARK, c Fo m CURRENT USE: TEMPLE MASONIC/ FAX (503) 656-5305 T-1 TITLE SHEET AND GENERAL INFORMATION! TELECOMMUIJICATIONS DDUTTOND TO FOLLOW SLIGHT RIGHT ONTO CA-J6/CA-99 CONTINUE FACIU LEGACY-1MRELESS.COM TO FOLLOW CA -99 S. G-1 GENERAL NOTES T�, 3 PROPOSED USE: TELECOM H FACILITY PROPERTY OWNER: CHICO-LELAND STANDFORD. MASONIC TEMPLE -TAKE EAST AVE. RAMP. A-7 SITE PLAN POWER: ,PG @ E ASSOCIATIONI -TURN! RIGHT ONTO EAST AVE. A-2 ENLARGED SITE PLAN AND ELEVATION P.O. BOX , TELCO: SBC PACIFIC BELL w CIICO. CA. 95927 -ARRIVE AT 1110 W. EAST AVE. A-3 EQUIPMENT DETAILS IW/1 530-342-7143 JURISDICTION: BUTTE COUNTY - A-4 ANTENNA DETAILS • ZONING: A-5 AGRICULTURE SITE OWNER: T -MOBILE DIANE TARDIFF A-5 ANTENNA DETAILS APPUCABLE CODE: 2001 CALIFORNIA BUILDING 425-398-7550 ' STANDARDS CODE E-1 GROUNDING PLAN AND DETAILS CONSTRUCTION) TWE: V -NJ OCCUPANCY TWE: UNOCCUIPED r PROJECT AREA: 49 SO. FT. z C C F � 1/I PROJECT TEAM o o v GAZLEY c l ea rw're® • • •T• • •Mobile' PLOWMAN —O PACIFIC TELECOM LEGACY ARCHITECTS T 1 W ....... wlrelexl se -Ices . TI SeEET .1. 5508 LAKE WASHINGTON BLVD. 568 FIRST AVE S. SUITE 650 4252 SE INTERNATIONAL 19807 H. CREEK PARKWAY N. 2701 NW VAUGHN. SUITE 764 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTSRS oD4R mrwermn U SUITE 300 SEATTLE, WA 98104-2804 SUITE F BOTHELL, WA 98011 PORTLAND, OR 97210 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER- 4 KIRKLAND. WA 98033 MILWAUKIE, OR 97222 THAN THAT WHICH RELATES TO CLEARYARE SERVICES IS U STRICTLY PROHIBITED. REM510N 2 a: a P P - P r f r F P P P P P f Y N rnJIM b Hg�m � tE ZO NMI I, bill Moll Aim Ig F g yR� $ 6Rig. a) rn m AN D 52 g a m 1 i I ISSUED FOR &%Ar I S EAST AVE / T-MOBII_,E 3� 1 2 SSUEDFOR 5U9MRT Q € "q a � CA-CHCOU 91- ° ^ d a 8 �an� 111 W ROAD CHICO. CAST95925 ffl 3 • PACIFIC TELECOM SERVICES 4568 1ST AVE S #950 0 SEATTLE. WA 98104 ♦ PHONE (206) 342-9000 ♦ FAX (209) 903-8513 • -WWW.PTSWA.COM N m 0 O O) m N x 4 clearw're• 20HE AR -AC. RES. 1 I ZONE AR -AC. RES. ZONE: AR-AG.R6 I I ' I BUTTE COUNTY BUTTE COUNTY I BUTTE COUNTY ZONE: R4 I I I I TT RESIDENTIAL TOWNHOUSES I BUTTE COUNTY Q I - ADJACENT ZONING ZONE AR -AGRICULTURAL REeDENT1AL I - - — - - - - — - _ _ _ _ _ _ _ - - i - - i I ' PACIFIC TELECOM BUTTE COUNTY I ZONE R4 I RESIDENTIAL TOWNHOUSES I I v ZONE AR -AG. RES. 1 I ZONE AR -AG. BUTTE COUNTY BUTTE COUNTY RES. ZONE: AR -AG. RES 1 BUTTE COUNTY I BUTTE COUNTY v - CAZLEY ARQiITECTS ARCHITECTS I�,m,,, ``\ I Parllm6 o-. arno I Q em n4 Tem em nA Tem Em W ZONE AR -AC, RES. I ZONE: AR -AG. RES OZONE:AR-AG. RES (ZONE: R4 RESIDENTIAL TOWNHOUSES i - BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY _ - I PROPERTY UNE BSB' -7' o IF � AI 0 �IPRW' • I pOSTINC I50' T- �1DOLE LATTICE IT EXIST LANOSCAPINC� ER ALL THAT CERTAIN REEL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, TOWER W/ PROPOSED / w OF CHICO. DESCRIBED I ICLEpRCITY /• //�////•//////////. //%/// AS FOLLOWS: I ,ANTENNWIREAS �I . TAX PARCEL ID: ISI I 'O NAP 42. LOT 197, BLOCK 07 I ADJACENT ZONING ZONE: 5-R-1/2 SUBURBAN RESIDENTIAL EXISTING a I C <_ N TEMPLE SITE ENTRY BUTTE COUNTY I� RICULN jBaum COUNTY g T I� ADJACENT TONING Ic. � S H I 1 J I . I ZONE: S -R -T/2 SUBURBAN flE90ENRAL I I' U X BUTTE COUNTY bLEIn T, PARKING LOT I EXISTING GARAGE 30 PROPERTY UNE 858'-Y 1 l� ADJACENT 70NING1 ZONE A -S AGRICULTURAL 58'-1•115'-0" LEASE AREA 80Z•_2• 1 1 1 BUTTE COUNTY \ 666'-3•EXIST T - I I - MDSCAPINC LAND C 1 \ \ ZONINGZONING BUTTE \ \ ZONE A -S AGRICULTURAL , CO BUTTE COUNTY \ \ o \ o IT, 1 0 z \ j0 NORD AVE.A-1 Evi n i• L�1T E �LlU r SI A*1 EN9QI 2 - I� .'-- N m 0 O O) m N x 4 WOO'VMS.d'MMM ♦ £LS8-£O6 (90Z) XVd ♦ 0006-Z4£ (90Z) 3N0Hd ♦ VOL96 VM '3111V3S • 099N S 3AV ISL 9990 S30IAa3S W003131 OIJIOVd �� ONS B VO '03M OV08 15 3 M olll r 'P I -SH g q VI-. $i$g 3 6RR /� �/��� T i j$� 8 3IR91- u /� l 1 / .1/ \� `��./�..-fix .lJ �' .1 I 1/l3anaod a3ns511 �1 is Sn0ISIA311 z 0 6 � � Y m da s Who I e a Q I y Z ti � WiE b O Z 3 a ZZ Z U y ¢ g8 V Q Z !pXy b m SgS (x Fe w'z $ g afS ibls S �' 8 Sn 1NLL 2 SAH S9 8 I §b -_ 1N11DW tlNN3LNtl 3aMatl3O 0350d0ad 10 -1'0 ,0-.90I r1�, - 1HO0H a3M01 3119ON-1 ONLLSOO .0 -,OCL .y' N 1 I m l, x o Ow �% Wo 20 ZHIm.Iy Faii 8 ��o Nyom $ QSXf U0 wi�=I." im $ agkl oo u F4 uS�kffi �.I�Sy�Irm�. ;J V H 1035 < va .0 ZV I I NOLO35 S€U I SU� 0 'rj n o X 6 bo - ' n �m 0 s� ' V3HV (33]N33 ONLLSO(3 .0 -,ZZ LI clearw're• GPS ANTENNA ePACIFIC TELECOM s GAZLEY C PLOWMAN 2M NN V gM ARCHITECTS ' DIA RCS - an. m4 . SITE SUPPORT = 27 AUI eoa m T90N 274 am Tem rm CABINET QQF ELECTRICAL m� m ^ PANEL 3* -0r POWER j RECEPTACLE 2'-1' SITE SUPPORT CABINET IT* � U wQ S i m 2' DIA SCH. 40 SPVC j CONDUIT EW STEEL i TELCO BOX (PPHk M ®® 2' DIA SOI. 40 PMP-3877LT� PVC TELCO W o;= CONDUIT •I •I o I * O n U oa SITE SUPPORT C0 CABINET ELEVATION 9TE SUPPORT CABINET ELEVATION 4 e GPS ANTENNA r---_--- I I TELCO Box it:o I I S �$ PANE I I $ u G1 B I I a w I I IA B POWER L -------r 'o RECEPTACLE 0 - m HVAC UNIT Tii •I m %iS H ,yOy ap 5t F tr HT1L STEEL EQUIPMENT O Q JL PUTFORN N m11Iir (PPHk PHP-3872LV) ea ®® 0 O 7 7 to �e NOTE: - FOR ANCHORING PLATFORM E _ B/A4 g SITE SUPPORT CABINET ELEVATION SITE SUPPORT CABINET ELEVATION A ^ —� A ` EQUIPMENT ELEVATIONS EQUIPMENT PLAN muw¢xr • SNL: lN'Xm2 a/4'-1'-0' 2 SCNA ((241M -k 1 REW90N 2 (II'%IY'V T � 1'-0' 6 1/6' (ENGTN:5 ((121 MM) ® WIDTH: 8.12' (155 MM) WE CMT: 12.6 O. J83 C GPS SPECIFICATION seAHe (z4xxz MUT ro seAaF 3 xus 0+'+U>7xm ro awt f 7 } B. •I IENGTH: 35.8' WIDTH: &5' DEPTH: 4.5' WEIGHT: S.S LBS ANTENNA SPECIFICATION scue (z4'xx� xm ro stat 5 s�.•.. Dt'zTTT rror ro stat O DIAMETER: SEE NOTE DEPTH: &2' OFFSET: 12.Y WEIGHT: 27 LBS LArni 2' N( m NOTE: PROVIDE (3) 2' DIA. @ 6" THICK CONIC. (2) 1' CIA MICROWAVE SLAB WITH /4 ANTENNAS. z MICROI - (1'-0 1-16.2 MICROWAVE SPECIFICATION SECTOI sue (247=" MOT TO SINE 1 EXISTING (RUSHED sac (+nnrp rnT TO scuz ROCK BASE INSTALLATION 3 MICRC HARD MANU 5 ji. ANm HARD MANU LENGTH: 18.3' (46 CM) ..T.:11.3' (z&S GM) DEPTH: 5.1' (13 CM) WEIGHT: 35 LBS (15 KG) L_je BTS I� e° ANm BTS SPECIFICATION SCXD (24`10r) Mor TO sr bz 4 su4s: O+Y+T'b MOT TO swz COAX ANm PROVIDE 5/B' HILT ETHE KWIK BOL%S WITH FROM PREFAB EQUIP 4. EMBEDMENT (AS BASEREQUIRED O EACH SEE I . SPECS PLATFORM LEG) TELC( SLOPE E)ISTING NATIVE EARTH stue (z4�xx-p xor ro stat 6 sr•,.. (++'MTT'=tmr ro scuz 2- 2 O U clearw're• 3 F PACIFIC TELECOM ♦GAZLEY :2 • PLOWMAN ARCHITECTS 0] iMixm. b. xJTO I n4 Te W m M FDs 274 TBWT Fax g O N A-4 J 4x+OtxA aTuu U I�M90N 2 U IL 6" THICK CONIC. SLAB WITH /4 REBAR AT 12" ON WACH WAY AT MID SLAB TYP. - NOTE VERIFY LOCATION OF RE -BAR EXISTING (RUSHED PRIOR TO ROCK BASE INSTALLATION E)ISTING NATIVE EARTH stue (z4�xx-p xor ro stat 6 sr•,.. (++'MTT'=tmr ro scuz 2- 2 O U clearw're• 3 F PACIFIC TELECOM ♦GAZLEY :2 • PLOWMAN ARCHITECTS 0] iMixm. b. xJTO I n4 Te W m M FDs 274 TBWT Fax g O N A-4 J 4x+OtxA aTuu U I�M90N 2 U IL • ro i clearw'reO e MICROWAVE O 1J0.79' PACIRC TELECOM • GAZLEY 'p 2' NOM. DIA. MOUNTING PIPE ' PLOWMAN ARCHITECTS I Pev V4 o. arno em n4 TLOD m1 n4TmT Fm eMICROWAVE O 128.39' C W LATTICE TOWER dM W O e MICROWAVE' O 11283' om O 3 MICROWAVENOUNTING a 8 HARDWARE BY MICROWAVE ' MANUFACTURER r ' ANTENNA MOUNTING HARDWARE BY ANTENNA MANUFACTURER O e BTS 0 ANTENNA e � �O rrrrrrLLLLLL 0 O ww -0 CO A% JUMPER FROM - ANTENNA TO BTS ETHERNET CABLE . TS BTS TD A-5 TMOMELCO TELCO ' SLOPE RPE MOUNT NTiDaA MNUI TOWER SECTION ® SECTION 2 � bSNG (11YIY) a/1' - Y -V REVISION 2 • ro i No I. SERVICE POWER TO EQUIPMENT SHALL BE 120/240VAC, 1WA0. SINGLE PHASE 2. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY BEFORE THE START OF CONSTRUCTION. POWER AND TELEPHONE CONDUIT SHALL BE PROVIDED AND INSTALLED PER UTILITY REQUIREMENTS AND UTIUTY. 3. -ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH THE N.EC., UTILITY COMPANY AND LOCAL CODE REQUIREMENTS. LOSS OF POWER RELAYS (LPRe) WILL MONITOR UTILITY POWER, 4. GENERATOR 1 POWER @ GENERATOR 2 POWER. LPRo SHALL BE LOCATED WHTHIN NEMA 3R JUNCTION BOX. LPRO SHOULD BE FUSED TO ELIMINATE THE RISK OF A LPR FAULT/FAILURE CAUSING THE MAIN POWER FUSES TO TRIP. UTIUTY-120/240V 1 -PHASE. 3W 3-X/0 + 1-/3 GRD IN 2' OCNOUIT IOOA 120/24OV, 1 -PHASE 3W OISTIBUTION PANEL WW/INTERGUTED MANUAL TRANSFER SYATCH AND A/C POWER TVSS ONE LINE DIAGRAI 2- (24'X]0'% Nor to SONE SUIS (11' n NOf N OWE BACKFILL (SAND OR NATIVE SGL) PER ASTM STANDARDS 2'0 CONDUIT WHERE APPLICABLE COORDINATE SIZE AND TWE WITH LOCAL UTILITY B' MIN. TW. CONDUIT TRENCH 3 sxe (24'X]0') NOf N t- SViC (11'YtrNm m SONE (3)-N/0 IN 4 Z' CONDUIT ■ CAD WELD CONNECTION M METER (BY CONNECT PER MANUFACTURER CONTRACTOR) 3-/3/0 + GR NO BAR MOUNTED i-/3 GRD IN TOWER AT ANTENNA 2' CONDUIT 1Lµ GR 0 r----� I- 1ODA PROPOSED CLEAR RE MAIN ANTENNA MOUNT (THP.) DISCONNECT L 3-X/0 + 1-/3 GRD IN 2' OCNOUIT IOOA 120/24OV, 1 -PHASE 3W OISTIBUTION PANEL WW/INTERGUTED MANUAL TRANSFER SYATCH AND A/C POWER TVSS ONE LINE DIAGRAI 2- (24'X]0'% Nor to SONE SUIS (11' n NOf N OWE BACKFILL (SAND OR NATIVE SGL) PER ASTM STANDARDS 2'0 CONDUIT WHERE APPLICABLE COORDINATE SIZE AND TWE WITH LOCAL UTILITY B' MIN. TW. CONDUIT TRENCH 3 sxe (24'X]0') NOf N t- SViC (11'YtrNm m SONE MECHANICAL CONNECTION clearw're° TELECOM v...... CAZLEY PLOWMAN M MN �. ARCHITECTS Wt. Tea RbOmd. a. 9M0 OD] V4 ]400 F V4 ]eN im 4 Q MECHANICAL CONNECTION clearw're° TELECOM v...... CAZLEY PLOWMAN M MN �. ARCHITECTS Wt. Tea RbOmd. a. 9M0 OD] V4 ]400 F V4 ]eN im (DOUBLE HOLE WG) Q ■ CAD WELD CONNECTION m CONNECT PER MANUFACTURER ♦ SPECIFICATIONS N GR NO BAR MOUNTED to TOWER AT ANTENNA 'TO GROUND BAR LEVEL 0 BTS 0e GROUND LEAD TO TO EXISTING GROUND PROPOSED CLEAR RE 0 ANTENNA MOUNT (THP.) ° ANTENNA EXISTING GROUND RING °EDGE OF / I SLAB ``f//` EXISTING GROUND RING U a 12 SOLID IN 2 w I FLEXIBLE c NON-METALLIC O CONDUIT LEAD TO FINISHED GRADE OR EXISTING GROUND RING dPACIFIC 05 GROUND LEAD TO clearw're° TELECOM v...... CAZLEY PLOWMAN M MN �. ARCHITECTS Wt. Tea RbOmd. a. 9M0 OD] V4 ]400 F V4 ]eN im GROUND BAR IN Q OTHER PROPOSED m TELCO BOX VAR N to dd 0 0 o 0 J2 GROUND LEAD 0 TO EXISTING GROUND 0 RING ° L I I EXISTING GROUND RING U a � 2 w I SITE RT I c A O CABINET FINISHED GRADE OR Z 0 J I I I PAVING. MATCH SLOPE ANDINTERNAL LI GROUNDING SCHEMATIC m— I SSC THICKNESS OF 3$ a I I GROUND BAREXISTING < D- CONDITIONS L -------I N -UNDISTURBED SGL ♦ COMPACTED BACKFILL WITH SATISFACTORY NATIVE OR IMPORTED SGL UTILITY WARNING dPACIFIC 05 GROUND LEAD TO clearw're° TELECOM v...... CAZLEY PLOWMAN M MN �. ARCHITECTS Wt. Tea RbOmd. a. 9M0 OD] V4 ]400 F V4 ]eN im U < n m n 0 N Q OTHER PROPOSED Q q 0 {Sar 0 CLEARWRE ANTENNA MOUNT (TYP.) N to dd 0 0 0 J2 GROUND LEAD 0 TO EXISTING GROUND 0 RING ww w L N EXISTING GROUND RING (i � 2 w d m 0 c A O w GR EXISTING GROUND RING Z 0 J _ `0. a LI GROUNDING SCHEMATIC m— o LL t- (24 00'}, Nor m OLNE 3$ a Q V 0 < D- N ♦ TYPICAL FOR ALL SSC INTERNAL S < u Q COMPONENTS Q q 0 {Sar Earp to dd 0 0 i ww w U ATTACH TO TOWER 2 w ,. GROUND /2 SOLIDE IN FLEXIBLE NON-METAWC CONDUIT LEAD TO' 0 GR EXISTING GROUND RING J tWWNgNO RAN GROUNDING SCHEMATIC m— o LL t- (24 00'}, Nor m OLNE ' S+Y4E (11'lllT'N Nor 10 $VIE REVISION 2 < D- Radiofrequency Emissions Compliance Report C4-CHC011 East Avenue/T-Mobile, Chico, CA 1 APPENDIX C Other RF Emissions Sources (from FCC database) in Vicinity of Project Site 0 EBI Consulting 14 Clearwire Corporation 5508 Lake Washington Boulevard, Suite 300 Kirkland, WA 98033 CA - CHC01 I -East Avenue/T-Mobile 1110 W. East Road Chico, CA 95926 Vicinity Location A. BI C 0 *N .5 U, 1,.T 1 N C CneaiAn:gYdue (sr.1!pur: guxfiners: 6 . 11 Subject Property 0 'Val, Radiofrequency Emissions Compliance Report CA-CHCOI l t, "' East Avenu&T-Mobile, Chico, CA 9 APPENDIX D ROOFVIEWO CALCULATIONS/EXPORT FILES EBI Consulting 15 140 File, Edit View Insert Format Tools Data Window Help Adobe PDFType a question Yor .e€p S x Rq ioo i R161 C46 fx FCC 1997 Public Ao. ��f� a Use Selected AEgnif oa rivq,v1 tlf, Ht • ,❑d ,��,.,., I ldui)Pui . 5puLlul A ay . ��� w x,F� i i I�If Sel Area AntennFF 7 ON OFF (7 SEL 1 DblCll — ON O... Time = t2:oo PM❑Use T x i Chg Map Recalc,Area Calc Ore Pizel Last Area Roof. Thresholds Calculator Statistics Snap'Phofo 9, 101 11 dr 120' 130. 140% 150'. f 0:2109073 Is ,% MPE at this location W OK z @ > 30 [ a f C 'ua,°*'""w"".`" - � - .. _•.,�:� - - ��-- ..... ,...,�, � :�twww.yu..gwl+uuuu+�wp�- �...w 3 U Z if I iJr tni f i � E t f g � 5 it -� ► ►i; AntennaData_. S mbolTable Irrtroduction �AntennaMap.i(_.......... .Y...._.._._.................._.. _ .._._........... l r, 140 Map, Settings, Antenna, and Symbol Data Table.. Exported from workbook- RoofView 4.15.xls Done on 8/10/2006 at 2:02:20 PM. Use this format to prepare other data sets for the RoofView workbook file. You may use as many rows in this TOP header as you wish. The critical point are the cells in COLUMN ONE that read'Start...' (eg. StartMapDefinition) If used, these (4) headers are required to be spelled exactly, as one word (eg. StartMapDefinition) The very next row will be considered the start of that data block. The first row of the data block can be a header (as shown below), but this is optional. When building a text file for import, Add the Map info first, then the Antenna data, followed by the symbol data. All rows above the first marker line 'Start. :.' will be ignored,, no matter how many there are. This area is for you use for documentation. . End of help comments. You can place as much text here as you wish as long as you don't place it below the Start Map Definition row below the blue line. r You may insert more rows using the Insert menu. Should you need additional lines to document your project, simply insert additional rows by highlighting the row number adjacent to the blue line below and then clicking on the Insert menu and selecting rows. Max) Map Max Y Map Max ) Y Offset X Offset Number of envelope 57 71 90 90 30 10 1 $U$134:$C$U$134:$CM$190 StartSettingsData Standard Method 4 StartAntennaData ID Name A Clearwir B Clearwir C Clearwir T1 T -mobile T2 T -mobile T3 T -mobile T Omni T -mobile StartSy )IData Uptime e e e Scale Facti Low Thr Low Color Mid Thr Mid Color Hi Thr Hi Color Over Color Ap Ht Mult Ap Ht Method 2 1 1 20 1 50 2 100 2 3 1.5 1 It is advisable to provide an ID (ant 1) for all antennas 3 , 30 (MHz) Trans Trans Coax Coax Other Input Calc (ft) R Freq Power Count Len Type Loss Power Power Mfg Model X Y 2500 30 50 50 Stella Dora26SD9890 31 2500 120 VC 50 50 Stella Dora26SD9890 31 2500 10 50 50 Stella Dora26SO9890 31 1900 100 100 Unkown 31 1900 100 100 Unkown 31 1900 100 100 Unkown 31 1900 100 100 Unkown 31 (ft) (ft) dBd BWdth Z Type Aper Gain Pt Dir 30 106 VC 3 17 90;90 30 106 VC 3 17 90;180 30 106 VC 3 17 90;270 30 120 VC 6 65;90 30 120 VC 6 65;180 30 120 VC 6 65;270 30 135 VC 10 omni V. , 0 11 ' r r dearwte CLEARWIRE WIRELESS, LLC USE PERMIT APPLICATION for Collocation of Telecommunication Equipment on an existing T -Mobile Lattice Tower CA-CHCOI 1 Submitted to Butte County Development Services Department July, 2006 GENERAL INFORMATION Landowner: Leland Stanford Masonic Temple Association POB 784 Chico, CA 95927 530-342-7143 Applicant: Clearwire, LLC 5808 Lake Washington Blvd., Suite 300 Kirkland, WA 98033 206-255-3929 Representative: David Wiltsee, Planning Consultant Epic Wireless Group 381 South Lexington Drive, Suite 103 Folsom, CA 95630 530-878-9117 dwiltsee@sbcglobal.net APN: 042-070-197 Current Zoning: A-5 Address of Project: 1110 W. East Avenue, Chico, CA 95973 Current Use: An existing 130 -foot lattice owned and utilized by PSC carrier T -Mobile. Masonic Temple Lodge. Na cel e t t t e t} t k h to W i w i Gridley .A Page I, . IJ View Help 9JNow Search :791 Pmporty Inf1onation ! Parcel 042-070-197-000 Acres 5.18 Address(s) Pfim@Ify Addf@@@ Mg_aMIRITAVE OHIN 0@73 Jurisdiction Butte County County Data Zoning A-5 - Agricultural. 5 acre minimum I General Plan OFC - Orchard and Field Crops Drainage Area Lindo Channel Supervisor District District 2 Flood Zone X FIRM Map Number 08007c0485 C Snow Load Elevation 0 to 1499 Feet. No Requirements L@g@nd wiscialmer; ounoLounry aces not guarantee met tne —. r awn provicea on mis site is accurate or complete. The Countyprovides es is information on an "as is" basis and disclaims all warranties, expressed - or Implied, including but not limitied to warranties of merchantability, fitness for a particular purpose and non -infringement. The County is not responsible for any damages arising from the use of this information. Access to this data is at users risk. Users should verify the information before making project commitments. Ii7010 fileWCADOCUME-1\DAVIDW-1TOCALS-1\Temp\90EDJANJ.htm 7/17/2 • EPIC wiaeLsoa WROUP INC. July 27, 2006 Richard Price Butte County Agricultural Commissioner 316 Nelson Avenue Oroville, CA 95965-3318 Re: Requested review of plan (Use Permit Application) to Collocate on Existing Tower on Agricultural Properties in Butte County Dear Mr. Price: Attached are plans for a broadband wireless antenna site that ClearwireLLC is planning in Butte County. The plan is to "collocate" antennas on an existing tower. According to the Butte County code, your office must review and approve of the plans to assure that the facilities will not interfere with crop dusting. The project and site are described as follows: Clearwire project number CA-CHCO1 1 - 1 1 10 W. East Avenue, Chico (APN 042-070- 197). This is an existing 130 -foot tower. Clearwire Wireless plans are to collocate antennas at the 1 10 -foot to 1 15 -foot level of the tower. Zoning is A-5. The project should pose no interference problems with' aircraft, as Clearwire will mount antennas at levels well below the top of the existing structure. The antennas will not project horizontally from the existing structure further than do existing sets of antennas on the same structure. If you would, please reply with a letter of approval as soon as possible, or e-mail me if you prefer. I appreciate your help in this matter. David Wiltsee, Planning Consultant EPIC Wireless Group/Clearwire LLC 381 South Lexington Drive, Ste 103 Folsom, CA 95630 530-878-9117 530-906-9771 Mobile dwiltsee sbcglobal.net A 381 S. Lexington Drive, Ste 103 A Folsom, CA'95630 A Office 530-878-9117 A Fax 916-984-3866 0 0 I. Project Description Clearwire. LLC, through its' agent, the Epic Wireless Group, is applying for a Conditional Use Permit to collocate and operate a wireless telecommunications facility for wireless internet on an existing 130 -foot tall lattice tower owned by T - Mobile. The tower is located at 1 110 West East Avenue (APN 042-070-197), on property occupied by the Leland Stanford Masonic Temple. The project consists of: 1. Mounting four (4) 3 -foot panel antennas/BTS units and four (4) 1' or 2' diameter microwave dishes on the existing tower (two of each) 2. Provision for one (1) future pairing of a panel antenna and BTS unit. 3. Placing one (1) 3'x 6' radio cabinet on an existing concrete pad within a 7'x 7' (49 -square foot) leased area, inside the existing compound. 4. Installing wiring connecting the tower facilities and ground facilities in an existing coble bridge. Existing communications equipment on the 130 -foot tower is mounted at approximately the 122' to 127' level (panel and dish antennas) and above the tower top (three 10 -foot omni whip antennas. Clearwire's panel antennas will be centered at the 113' level, the dish antennas at the 110' level. The Clearwire antennas will be affixed to the tower on a 4" diameter steel mounting pipe, as close to the tower profile as possible (projecting no more than 3' from the tower's vertical surface.) Attached drawings submitted with this application clearly show antenna arrays, site plans, elevations, and other equipment referenced herein. No additional fencing is required, as the Clearwire facilities will be located inside an existing compound fenced area (approximately 37.5'x 63.0'). Access to the site is via East Avenue. No excavation or grading will occur on the site. The other licensed carrier with equipment on the tower is tower owner T -Mobile. The Clearwire site will be unmanned and will not require water, waste treatment or management of hazardous waste. Minimal traffic will be generated during the construction phase while a crew is traveling to and from the site. After construction is completed, there will be approximately one visit per month by a radio technician for routine maintenance. The site will be in operation 24 hours a day, 7 days a week. 0 0 II. System Information Clearwire, LLC is a wireless broadband provider licensed by the Federal Communications Commission (FCC) to provide wireless high-speed Internet access to residential and small business customers nationwide. Clearwire has currently bought spectrum in 100 U.S. markets and will be operating using the emerging 802.16 or WiMax standard. Pursuant to the strict guidelines of the FCC license, Clearwire is obligated to provide coverage to each geographical area in which licensed to broadcast in. In addition to its responsibility to the FCC, Clearwire is committed to offer customers a system that meets specific standards of quality; one which provides continuous, uninterrupted wireless coverage throughout each market area. Clearwire's network operates through an interconnected system of antenna sites with radio signals needed to provide service. Unlike cellular or PCS systems, the Clearwire system is not designed to provide mobile service. A customer can, however, use a laptop or desktop computer anywhere in the coverage area. Clearwire uses a state-of-the-art wireless modem that can be plugged into a desktop computer, laptop, or local network. The wireless modem connects the computer to "outside world" by transmitting signals to and from nearby antennas, instead of using traditional phone lines or cable. This provides flexibility to set up a computer anywhere in a home or office — upstairs or downstairs, inside or outside. The network utilizes existing telecommunication towers and "building mounts" such as rooftops and water tanks. Each antenna site is connected to local utilities for power, and requires a phone line to monitor site operations. Microwave technology is used to connect each Clearwire site to other Clearwire sites in the local network. Each site typically consists of 1) three to five panel antennas, a number of small microwave dish antennas, and associated equipment mounted on a tower or other suitable structure and 2) ground -mounted radio equipment used for transmitting and receiving wireless signals One site is designated the local "hub site", or POP. Here, all the Chico -area sites will be connected to the conventional "land-based" phone system using T-1 lines. Through the land-based telephone network, the Chico -area network is connected with the Main Switching Center (MSC) that controls and monitors all of the sites in the northwestern United States. The MSC center serving Chico/Butte County is located in the State of Washington. 2 III. Site and Operational Information Clearwire specialists. selected this site, after extensive analysis, as one of several sites to provide coverage in the Chico area. The site location, antenna height, and tower height were determined by using a computerized propagation study, which evaluated the expected radio-frequency (RF) signal from the proposed sites at the available heights. All existing towers in the area were evaluated to determine how to provide coverage in the Chico area. Clearwire does not build any new towers or other support structures unless left with no feasible alternative. Instead, Clearwire relies on existing towers for the bulk of the "platforms" needed to build a system. Other platforms include buildings, water tanks, and power poles. , Consideration of local topographic and geographic factors, tree canopy, buildings, mountains, water bodies, and the ability to mitigate the antenna support structure's visual impact further refines the selection and design of a specific site. In addition, the facility must be compatible with existing and surrounding land uses, and must have a landlord who will negotiate and agree to a mutually beneficial lease. Radio signals must travel in an unobstructed path from the tower facility to the user; therefore, improper site location can negatively influence and/or limit the quality of radio transmissions to and from a site. For this reason, the height and location of each site is carefully selected and limited to a specific area that will function with the least amount of obstacles. Power levels emitted by the transmitters to be used at the proposed site are considered to be low -powered. The Effective Radiated Power (ERP) is less than 100 watts for the site, which complies with FCC license requirements. An EMF study is attached to meet Butte County requirements. FCC regulation of radio transmissions mandates that the proposed facility shall not interfere with surrounding properties or their uses. The FCC has determined that the power levels emitted by wireless communications facilities (less than an average light bulb - 100 watts) is well below the minimum safety standards established for continuous exposure to Electro -Magnetic Fields (EMF). The extremely low output of power from the proposed facility, in conjunction with FCC regulation, will ensure there is no interference with surrounding properties' electronic equipment, 2 -way radio transmissions, computers, satellite antennas, televisions and telephone transmissions. Further, negative health effects will not result from emission of signals from the antennas on the tower. The FCC has conducted numerous studies that reveal telecommunications facilities do not cause harmful health effects for humans and has categorically excluded licensed wireless carriers from causing exposure in excess of FCC guideline limits. 3 IV. Butte County Application Requirements (e) Application requirements. At a minimum each application for a facility permit shall include the following: (1) Application Materials. All application materials generally contained in the submittal requirements for the type of permit required. Incomplete applications shall not be accepted. Response: See the following sections. (2) Statement of Justification. a. Description of the proposed facility, including the type of facility being requested. Response: The existing facility is a 130 -foot tall guyed -lattice tower owned by T -Mobile. The current user of the tower is T -Mobile. T -Mobile also maintains ground equipment within a fenced compound at the base of the tower. T -Mobile's facilities were previously approved by the Butte County Development Services Department. Clearwire will install initially four (4) 3' panel antennas and four (4) 2' diameter microwave dishes in a tightly clustered "array". The panel antennas will be centered at the 113' level of the tower, the microwave dishes just below at approximately 110'. b. Height from natural grade to the top of the proposed facility. Response: The existing tower is 130 feet in height. The tops of the highest - mounted existing antennas are at roughly 140''. Clearwire antennas will be installed between the 109' and 114.5' levels of the tower as depicted in the attached plan drawings. c. Support equipment proposed. Response: The proposal is to collocate on the existing 130-foot.guyed tower and, within a 49 square -foot leased area inside the existing compound to house electronic equipment on a raised platform atop an existing concrete pad. The specific proposal - as shown on the attached drawings - is as follows: • Equipment to be installed on tower: • Four (4) panel antennas (3' length, 7" width, 8" depth) at azimuths of 0, 90, 180, and 270 degrees. Provision for one future panel antenna unit is also requested. • Four (4) microwave dish antennas at the following azimuths: 18, 89, 131, and 268 degrees. 11 One BTS (Base Transmitter Station) unit (19.3" length, 11.3" width, 5.1 " depth) is attached behind each panel antenna. The panel antennas are connected to the BTS units via a'/2" coaxial cable. The BTS units are attached to the ground equipment via 5/16" Ethernet cables. Microwaves are connected to the ground equipment via 7/8" coaxial cables. These are connected to the ground equipment via Ethernet cables. All cables are routed down the tower from the antennas and to the equipment cabinet via a cable bridge (see drawings.) d. RFR/EMF and wattage output date including the number of channels. Response: See attached EMF information. Power levels emitted by the transmitters to be used at the proposed site are considered to be low - powered. The Effective Radiated Power (ERP) is less than 100 watts for the site, which complies with FCC license requirements. e. Horizontal and vertical location coordinates. Response: 39 degrees, 44', 45.5"N, 121 degrees, 52', 56.1 "W, 167 ft AMSL at base, 275 ft to 281.5 ft AMSL equipment, 297 ft AMSL top of existing tower. (3) Elevations. Proposed elevations of the structure and any accessory buildings, including building height and other physical dimension, drawn to graphic scale. Response: See attached drawings pages A-2 and A-3. (4) Visual Impact Assessment. Visual impact assessment, photo montages, mock-ups as determined by the director of Development Services or Planning Commission. The assessment shall identity any proposed trimming of vegetation that will be required for the normal operation of the facility. Stealth technology is encouraged. Response: Attached are photos of the existing site as well as a photo simulation of the site with the Clearwire equipment in place. No significant vegetation exists around the site that needs to be removed or trimmed. Ground equipment will be hidden from view from East Avenue by a garage. All development will occur within the confines of the existing compound. (5) Alternative Site Discussion. A discussion of and support information regarding the alternative site selection of at least a minimum of three (3) or four (4) other sites, if available, including collocation opportunities, and a statement as to why these alternative sites and/or collocation opportunities were rejected. Response: Not specifically applicable, as this is a collocation site. (6) Service Area Map. A complete service area map showing the entire wireless communications network of the provider twenty (20) miles in all directions from the proposed site of the time period from the filing of an application to twelve (12) months from the filing of the application, for the purpose of visually aiding cumulative environmental analysis, with and without the proposed facility or facilities, showing all hand -of sites within the above specified area. Response: The proposed Clearwire Wireless network is not a cellular network and does not "hand-off" signal to other sites. The attached map (Chico Area Sites) shows all proposed sites within 20 miles of this site. This list is subject to change. All sites are scheduled to be approved and built in 2006, pending approval by the respective local governments. Twelve of 15 planned sites are collocation sites. Two are "roof mounts" in areas lacking opportunities for collocation on existing structures. One site is yet to be determined. As might be gleaned from the following list of sites, several "search rings" have been dropped altogether; the geographic area within them having been picked up by antennas in nearby search rings. • CHC001: Roof mount in shopping center, East Avenue (Chico) • CHC003: Collocation on existing guyed tower at 4439 Hwy 32 (Butte County) • CHC004: Collocation on existing water tower at 236 Orient St (Chico) • CHC005: Collocation on existing lattice tower in Orland (Glenn County) • CHC006: Collocation on existing monopole in Corning (Corning) • CHC007: Collocation on existing guyed tower - Estes Road (Butte County) • CHC008: Collocation on existing monopole at 1298 Nord Avenue (Butte County) • CHC009: Roof mount on Holiday Inn (Chico) • CHCO10: Collocation on existing lattice tower at 3415 Silverbell Road (Butte County) • CHCO11: Collocation on existing lattice tower at 1110 West East Ave (Butte County) • CHC013: Collocation on existing lattice tower on Elk Lane (Paradise) • CHC015: Collocation on existing monopine tree pole (Paradise] • CHCO16: Uncertain location on Skyway (Paradise) • CHC018: Uncertain location (Paradise) • CHC019: Collocation on existing monopole at U -Lock -It storage (Chico) (7) Search Ring. A graphic depiction of the search ring and all other technical criteria used in determining the proposed facility location. Response: See attached map (Search Ring). Clearwire search rings were based on tower registration information from the FCC. Based in these, other search rings were created. Unlike a typical cellular/PCS build, the engineers were able to work with what was available in and around the search rings to provide coverage. (8) Failure Characteristics. Documentation which identified failure characteristics of the facility structure or tower and demonstrates that the site and setbacks are of adequate size to contain failing debris. Response: A structural report is available showing the failure characteristics of the tower and verifying that Clearwire's added equipment will be supported by the tower. (9) Visually Unobtrusive Development. Written evidence demonstrating that the selected facility structure or tower design is as unobtrusive as possible, given technical and engineering considerations, which indicate what type of faculty is required to provide reasonably effective service and also the best technology and/or construction available to maximally achieve visual unobtrusiveness. The use of best available technology and/or construction to maximally achieve visual unobtrusiveness is mandatory. Response: Clearwire proposes to use only a total of four (4) panel antennas (3 feet in height), four (4) microwave dishes (2 -foot diameter), and four (4) BTS units (19.3" length, 11.3" width, 5.1" depth). The antennas will be mounted in a manner consistent with the existing Ubiquitel antenna array already on the tower. The BTS units will to be installed behind the panel antennas to lessen the visual impact of the equipment. The ground equipment will be located near the base of the tower, and will be minimally visible from any vantage point external to the subject property. (10) Common Carrier Facilities. Applicants which operate common carrier facilities (specifically, but not limited to cellular, PC, SMR and paging service licensees of the FCC) shall prove written evidence that he applicant has provided notice to all FCC licensed wireless communication service carriers operating with the County of Butte of the plans to develop this site. Response: Not applicable. This site is already constructed (developed), and Clearwire is seeking to collocate on the site. (11) FCC License. Evidence of a current operating license or construction permit .from the FCC or, if the applicant is not a wireless communications service provider, a user operating agreement for each and every such provider to which the applicant intends to rent space on the proposed facility. Response: Evidence of Clearwire's right and obligation to operate wireless broadband service in Butte County is attached. (12) RF Report. A report, signed by a qualified radio frequency engineer licensed by the FCC, prepared pursuant to FCC OET 65 stating whether the maximum radio frequency radiation/electromagnetic radiation (RF/EMF) to be emitted by the proposed facility, taking into account all other facilities, both existing and known future facilities, at the proposed site and adjacent properties, conforms to the safety standards adopted by the FCC, if applicable. The reports prepared for facilities shall conform to the reporting requirements set by the county and FCC OET 65 human exposure standards. The report shall also analyze the evidence provided in support of the proposed facility location, height and radiated power, frequency, the number of channels, and all other related data and present alternatives fore the location, height and radiate power, pursuant to the requirements of this section. If the proposed facility exceeds FCC OET 65 human exposure standards, applicant shall also provide additional comprehensive technical and planning information regarding how the applicant shall protect all persons from such excessive exposure consistent with all federal and state requirements, and any additional county requirements. Response: See attached information (13) Landscaping and Painting Plans. Landscaping and painting plans for the completed project. 7 • Response: No landscaping is proposed as part of this project. The entire project is within the confines of an existing facility on railroad property. Equipment mounted on the tower is to be a non -reflective neutral color. Ground equipment will be within an existing fenced compound. (14) Projects in Agriculture Zones. Projects in agricultural zones (A-5 through A-160) shall, prior to submitting an application for a proposed facility, submit a site plan of the proposed facility to the Butte County Agricultural Commissioner for comment and send a notification letter to all aerial agricultural applicators registered in the county informing them of the proposed site location and tower height. No hearing on an application for a proposed facility in any agricultural zone will be scheduled, nor shall any administrative permit for any such facility be issued without proof that the Butte County Agricultural Commissioner, and all agricultural applicators registered in the county have been notified, as specified herein. Response: The property is within an Agricultural zone (A-5). A letter (attached) will be mailed to the County agricultural commissioner, along with a set of plans, if the applicant is directed to do so by the Development Services Department. The applicant contacted the Agriculture Commissioner during preparation of this application, and was informed that such project notification typically occurs following submittal of a formal application to the County. (13) Comprehensive Airport Land Use Plan or Airport Area of Influence. All applications for facilities that are proposed to be located within the boundaries of any comprehensive airport land use plan or airport area of influence, as adopted or designated from time to time by the Butte County Airport Land Use Commission, shall be submitted to the department of development services, planning division, and a copy submitted to the Butte County Airport Land Use commission for review regarding consistency with adopted comprehensive airport land use plans and for recommendations addressing potential impacts to air navigation within the airport area of influence. Response: Not applicable. Not in such an airport impact area or airport area of influence. (16) Independent Consultant Review. The county may in its sole discretion retain an independent consultant to review either individual elements of or the entire application and advise the county at the applicant's sole expense. Response: Applicant acknowledges this section, but requests prior notification before such an action is taken by the County. (f) Development Criteria for Wireless Communications Facilities. The proposed development needs to meet development criteria for collocations on existing approved facilities. Additional facilities attached below the topmost existing facility array, either on the same pole or tower, or a replacement pole or tower at the same height, may be permitted subject to a minor use permit or a use permit and shall be subject to the following criteria: a. All equipment shelters, cabinets, or structures utilized or built in connection with the facilities shall be located within the building being utilized for the facility, or on • 0 the ground outside of any setback area or required vehicle parking space, or on the roof, if visually screened. Response: The equipment is to be located within the existing compound and not in any required vehicle parking space. b. Additional facilities shall not extend out horizontally from the pole more than the widest existing projection. The use of proximity designs is encouraged. Response: Clearwire antennas will project horizontally from the guyed tower less than 3 -feet. Some existing antennas on the tower extend outward more than 3 -feet. c. The antennas and pole shall be painted to match the color of the existing antennas and pole or tower, or shall be painted and constructed to blend with the prevalent architecture or natural features existing on the subject site, as determined by the director of development services. Response: The antennas areroposed to be a neutral color that will blend with the color of the tower (3) Collocations on existing approved facilities. Additional facilities attached below the topmost existing facility array, either on the same pole or tower, or a replacement pole or tower at the same height, may be permitted subject to a minor use permit or a use permit and shall be subject to the following criteria: a. All equipment shelters, cabinets, or structures utilized or built in connection with the facilities shall be located within the building being utilized for the facility, or on the ground outside of any setback area or required vehicle parking space, or on the roof, if visually screened. Response: Plans as submitted comply with these requirements. b. Additional facilities shall not extend out horizontally from the pole more than the widest existing projection. The use of proximity designs is encouraged. Response: Planned antennas do not project out horizontally as far as some existing antennas on the tower. The planned Clearwire antenna array is tightly clustered. c. The antennas and pole shall be painted to match the color of the existing antennas and pole or tower, or shall be painted and constructed to blend with the prevalent architecture or natural features existing on the subject site, as determined by the director of development services. Response: All equipment will be painted neutral colors to minimize visibility. (g) General Standards. (1) The minimum lot area for a facility shall be based on required setbacks. E • 0 Response: No new tower or project compound is proposed. The existing compound meets the setback requirements. (2) All facilities shall meet minimum setbacks. Response: No new tower or project compound is proposed. The existing compound meets the setback requirements. (3) All facilities shall be designed for the minimum functional height required. The height of a facility shall be measured from the natural, undisturbed ground surface below the center of the base of said monopole or tower to the top of the monopole or tower itself, or if, higher, the tip of the highest antenna or piece of equipment attached thereto. The use of best available technology and/or construction to achieve maximum visual unobtrusiveness is mandatory. Response: Collocating on towers is a function of determining what heights on the tower are available to lease and determining how well the site will cover given the available tower height. The tower owner/operator provided the designated levels on this tower after Clearwire determined the optimal tower locations for mounting an array of antennas. (4) The installation of any facility shall comply with all applicable building and electrical codes. All facility operators shall submit certification from a registered structural engineer to the building division that all associated monopoles and towers in excess of thirty (30) feet in height will withstand sustained winds as required by the Uniform Building Code. Response: A detailed structural analysis will be submitted with or prior to the building permit application as required. (5) No advertising or display is permitted on any facility. Response: No advertising or display is proposed. (6) The placement of any antenna shall not adversely affect any on-site sewage disposal system or its repair area without written approval from the division of environmental health. Response: The project will not have any effect on a sewage disposal system. (7) The installation of the facility shall not violate any existing deed restrictions. Response: No deed restrictions are violated. A copy of the title report can be made available from the applicant upon request of the County. (8) All facilities shall have a twelve (12) foot wide all-weather access to a publicly maintained road capable of supporting a forty thousand (40,000) pound fire apparatus with fifteen (15) feet of vertical clearance. Response: Clearwire intends to utilize the same, existing all-weather access as approved for the wireless carrier whose antennas are currently on the tower. 10 (9) There shall be no outdoor vehicle or equipment storage except for emergency purposes. Response: No outdoor storage is proposed. (10) All facilities must meet standards and regulations of the FAA, the FCC, and any other state and/or federal agency with the authority to regulate such facilities. Response: Clearwire understands and acknowledges this provision of the Butte County Code (11) No facility or combination of facilities shall generate, at any time, electromagnetic frequency radiation (EMF) or radio frequency radiation (RF) in excess of the FCC adopted standards for human exposure, as amended over time. Response: See attached RF/EMF information. (12) If it is found that facilities are or will be detrimental to the health, safety, or welfare of persons working or residing near such facilities, then the service provider(s) and property owner shall be jointly and solely responsible for the removal, adjustment, or replacement of the facilities. In no case shall a facility remain in operation if it is found to create a hazard to health, safety, and welfare. A facility shall not be found to create a hazard to health, safety, or welfare as a result of EMF or RF emissions from the facility so long as it meets all current standards established; by the FCC, pursuant to the FCC QET 65. Prior to issuance of the building permit for the installation of every facility, the applicant shall post a performance security in an amount and form determined by the director of development services that is sufficient to cover the cost of a one-time test by a radio frequency consultant selected by the county, sufficient to determine whether the facility's RF/EMF emissions comply with FCC standards. If the Facility's emissions are determined to exceed FCC standards, the applicant is required to pay for such other tests and other corrective measures as are necessary to establish compliance with FCC OET 65 and its successors and such noncompliance shall constitute sufficient grounds to commence a permit revocation hearing which may lead to permit revocation. The applicant shall cooperate in all respects with the county's consultant to assist the consultant to reach his/her conclusion. Response: Clearwire facilities meet the FCC guidelines. (13) Abandoned Facilities. All facilities that are not in continual use for a period of six (6) months shall be considered abandoned. The applicant shall post a performance security in an amount and form determined by the director of development services that is sufficient to cover the cost of removal of the facility in the event that such facility is abandoned, or if the permit has been terminated for violation of its conditions by the county after hearing, or has expired, and after notice has been given to the owner/operator by the county, no application for renewal has been filed. Response: Clearwire understands the 6 -month abandonment provision, and shall comply with the provision that abandoned equipment be removed if not used. In fact, prudent financial management dictates that usable equipment would be moved elsewhere were the site abandoned by Clearwire, rather than let it sit idle. 11 • Likewise, paying rent after abandoning a site would be economic folly. Under these circumstances, Clearwire requests a waiver of the bond requirement, contending that the requirement would be unnecessary to achieve the County's goals, and would tie up precious capital for Clearwire. (14) New towers within 1,000 feet of each other. Response: Not applicable. 'This is an application for collocation on an existing tower. (15) Prohibited locations. Response: Not applicable. This site is not in a restricted area. (16)AII ground level support facilities shall be painted and/or screened from view with adequate landscaping appropriate to the surrounding environment. All aesthetic treatments, including landscaping shall be maintained as approved for the life of the facility. Response: The planned ground equipment and antennas will be painted to blend with other on-site facilities. 117)Limiting the duration of a permit. Response: Clearwire requests a minimum 10 -year duration for the Conditional Use Permit. (18)Encroachment of facilities. Response: The proposed facility does not encroach into, under, over, above, or upon any public street in the unincorporated area of the county. (19)Annual written verification. The owner/operator of each facility shall annually submit a written verification, attested to under penalty of perjury, signed by both the owner/operator and an FCC licensee in the employ of or retained by owner/operator, that the radio frequency radiation/electromagnetic frequency (RF/EMF) emitted by a facility conforms to safety standards set forth in FCCOET 65. The reports prepared for facilities shall conform to reporting requirements set by the FCC and the County. Response: Clearwire Wireless acknowledges that the owner/operator of the telecommunication facility is required to submit an annual report to the County, and that the owner/operator may solicit from Clearwire an annual certification regarding RF emissions and compliance with FCC safety standards. (19)Traffic Impacts. Response: The construction of this facility will take approximately a week with a few vehicle trips per day. After the initial construction period, the site will be visited periodically, typically once per month. 12 • • (20)Development Schedule. Applicants may be required to submit a development schedule if the director of development services determines that nearby property owners may be inconvenienced during construction. Response: Clearwire will gladly submit a schedule with the building permit application. (21)Securing facility. Response: The facility is secured at the fence line, and, as with all railroad property, is guarded by railroad security. (22)Neither the applicant, nor any agent nor representative of the applicant shall intentionally omit or misrepresent any material fact in connection with the application. Any alleged material misrepresentation shall constitute grounds for the director of development services to commence a revocation hearing, ad, if proven to exist, shall constitute sufficient grounds to revoke a permit. Response: The applicant acknowledges that the proposed project has been accurately described in this narrative and accurately represented in the application materials. 13 0 • Primary and Secondary Search Ring/Alternate Site Selection Map 14 0 Map of Service Area The approximate coverage area within 20 miles of this site is shown below. , ro y j T a j tl i S� f1 8 U T 1 E n.. � ip:1°oa di: j i �enoswee .67m i m ` I b1 SOV 1 o S f 1 t 15 • Sites within 20 miles of the Estes Road Site mites in or wear Uty of unico Sites in or Near Town of Paradise CopyAgnt O 1988.2009 Mtposdt carp. andlor its suppliers. All rlghts reserved. hap:/A•nxv.miuosolt.corn9treets/ O Copyrigh12008 aY GepgrepNc Oata Tedtndogy. Inc All rights reserved O 2099 NAVfEO. NI rights resented. This data indudes W—anon taken with P—tiSsion Iran Canadian authorities O Her Majesty the Oueen in Hight of Canada. 16 9 s 01WZ) III l.,VlIIII l CII IU VI ICU IU Copvrighl O 1988-2009 Kmos011 Coro. ands its suppti— All rights reserved. hep'A v.—M011.-Wslreelst O Cnpyngh12003 by Geogmprk Data Ted+ndogy. Inc. All ryles O 2OD4 NAVTEO. All rights reserved. This data induum inlmmatim taken with permission tram Canadian authorities 0 Her Majesty the Oueen in Hight of Canada. 17 { e � '.f, �•.Y. ..� `fir .%' ._/ ' � � .r . . ifY� 7F4 �`�� j• � - lX, .,+� fly, al •�,•� �..� .err "rri�:•' t' rf .. ,.�.. 4 :`. 1 jr •. .. ' ter..: ,, • ; : :, _ ' _:.,, r;, .r � .. 'r 1(.. `�{' ` as=..,; a I%fir•-""i. 1 �� .'s -�� � 'S1 1'{' I -•t + � '/, ``''ice. � � i � j'nr f +'•-• I .'l� 't .�,; 4�r•r..�1 ;may .. � � ' . E PROPOSED EAST AVE. CA-CHC011 .> WUTTE COUNTY RECEI19 7 County Center Drive Oroville, CA 75965 Depaded ices Phone (530) 538-71381 Fax (530) 538-2140 Project Number: UP06-0022 Site Address: 1110 W EAST AVE CHICO, CA Site Apn: 042-070-197 Applicant: Clearwire LLC 381 South Lexington Dr. Suite Folsom, CA 95630 Description: Colocation of existing tower Fee Description Publishing Fee Chico ER Total Fees Paid: Date Paid: 1/3/2007 Paid By: Clearwire LLC Pay Method: Check 54145 Receipt Number: P274 Received By: DEL Account Number Printed': 1/3/2007 5:12 pm 0 Fee Amount 0010-440001-4210900-1010 $110.90 `-, $110.90 2 1 6-7POO -wirehn� broadban4 �1 E �� Check Number 12, .L'?T X,Dates i -'06054'145: 29 DEC -06:z �1 E ti DECLARATION OF FEES DUE (California Fish and Game Code Section 711.4) NAME AND ADDRESS OF APPLICANT Clearwire LLC 0 L 381 South Lexington Dr. Suite Folsom, CA956300 DEC 1 36 CANDACE J. GRUBBS, BUTTE CO. CLERK DEPUTY FILING NO. Project Title/File Number: USE PERMIT, UP06-0022 APN: 042-070-197 CLASSIFICATION OF ENVIRONMENTAL DOCUMENT: 1. NOTICE OF EXEMPTION/STATEMENT OF EXEMPTION (X) A. Statutorily or Categorically Exempt $36.00 Clerk's Documentary Handling Fee ( ) B. De Minimis Impact - Certificate of Fee Exemption $36.00 Clerk's Documentary Handling Fee 2. NOTICE OF DETERMINATION - FEE REQUIRED ( ) A. Negative Declaration $1,250 State Filing Fee $36.00 Clerk's Documentary Handling Fee ( ) B. Environmental Impact Report $850 State Filing Fee $36.00 Clerk's Documentary Handling Fee 3. ( ) OTHER (Specify) $36.00 Clerk's Documentary Handling Fee PAYMENT / NON-PAYMENT OF FEES: 1. (X) PAYMENT: The above fees have been paid. See attached receipt(s) # 456687 & 456688 2. ( ) NON-PAYMENT: The above fees are required. Not paid. Chief Plannine Official By: Tim Snellings, Development Services Title: Director Lead Agency: Butte County Department of Development Services Date: December 12, 2006 TWO COPIES OF THIS FORM MUST BE COMPLETED AND SUBMITTED WITH ALL ENVIRONMENTAL DOCUMENTS FILED WITH THE BUTTE COUNTY CLERK'S OFFICE. THREE COPIES OF ALL NECESSARY DOCUMENTATION ARE REQUIRED FOR FILING. ALL APPLICABLE FEES ARE DUE AND PAYABLE PRIOR TO THE FILING OF ANY ENVIRONMENTAL DOCUMENT WITH THE BUTTE COUNTY CLERK'S OFFICE. MAKE CHECKS PAYABLE TO THE COUNTY OF BUTTE. APPENDIX A il i� NOTICE OF EXEMPTION Office of Planning and Research 1400 Tenth Street, Room 121 Sacramento, CA 95814 X County Clerk County of Butte 25 County Center Drive Oroville, CA 95965 Project Title: USE PERMIT, UP06-0022 Assessor's Parcel No.: 042-070-197 ApplicantClearwire LLC 381 South Lexington Dr. Suite Folsom, CA95630 FROM: Butte County Planning Division 7 County Center Drive Oroville, CA 95965 Project Location -Specific: 1110 W EAST AVECHICO, CA Project Location -City: Project Location -County: Butte Description of Nature, Purpose and Beneficiaries of Project: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound Name of Person or Agency Approving Project: Butte County Planning Commission or Butte County Board of Supervisors Exempt Status: (Check One) Ministerial (Sec. 15073) Declared Emergency [Sec. 15071(a)] _ Emergency Project [Sec. 15071 (b) and (c)] X Categorical Exemption. State type and section number: 15311 Statutorily Exempt — 15274(a) Reasons why project is exempt: Section 15311 consists of construction of minor structures accessory (appurtenant) to existing facilities. Antennas placed on an existing communications lattice tower are considered to be accessory structures; Contact Person: Chris Tolley Telephone: (530) 538-7601 If filed by applicant: 1. Attach certified document of exemption finding. 2. Has a notice of exemption been filed by the public agency approving the project? Yes No Date Received For Filing: r arles istlethwaite, Development Services Planning Manager 05M92-022: KAR04 A lWo' IER; DET 07-01 G42-070-197; CLLEARWRE; UP 07-06 +42-070-197; C:LEARWRE; UP 07-011 N00j*40E -CLERK'S FILING FE GENL 0010 (.$38) Project Number 0510-092-022; KAPStkl Y4AGNER; DET 07-01 042-070-197: CLEr9FWRE; UP 07-05 042-07()-197; CLEARWRE; UP 07-06 7uQo�- �'�'a• AGRICUL T URE AG FEE 0010 Proieci Number _ 05"92-022; KAREr�l'fVF\G1dER; DET 07-01 042-070-157; CLEAWIRE; UP 07-06 042-070-i-97; CLEAR0ARE; UP 07 -OE, $ .4.00 $ 119.04 $ 227 96 470001 46123.19 3179009 I $ 36.00 , $ 12.36 COUNTY OF SL• t I _ 23.65 <<Fs: lri1 i AUDITOR'S CERWICATE AND TREASURE -R'S RECEIPT Amount of Fee �} OROVILLE, CA $ 11 15 t 21.35 ATR NO 97776 I. RECEIVED FROP9 PLANNING BAG =. :330 DAT]-= FUND FUND DEPT ACCT CASH DESCRIP T ION TITLE CODE CODE CODE CODE AMIOUNT lDEPOSITDA ►*E: 31!7 -- — RECEIVED ON: 8116 RECEIPTS: 4596p6- 464303 PLANNING NING AFPL FEES GENL t3C110 44(W1 4210900 'i01001 4,235.00 Project Number Amount of Fee 059-092-;122; KAREN Y,AGNER-, DET 07-01 $ 1,213.00 042-070-197: CLEkPNiRE; UP 07 -Oft- $ 1,098 88 1 042-070-197; CILE,%R�FlFeE; UP C17-05 $ i,P,51 14 I 085-i9&032, 033; BARB.AR.A i�LI 9INO; LLA 00-25 i $ 5200 LAND DEVELOPMENT GEMIL 0,010 4.4OW14 .1.611703 101001 781+3.01 Project Dumber I Anount of Fee 054092-022: KAREN WAGNER; DE T 07-01 $ 621.00 042-070-197; CIEARWRE; LIP 07-03 $ 56.80 042-070-1@7: CL.EARdhIPE: UP 07-06 $ i0840 EWRONMENTAL HLTH PH F-liND W21 5419013 4614501 909001 479.Mt Project Number Amount -of Fee 059-092-022; KAREN 01AGNER; DET 07-01 $ 47900 FIFE PLNG APPL FEE FIRE PROTECT 0100 -1DW!1 4617240 'I0/00i 401.00 Project Number Amount of Fea 05M92-022: KAR04 A lWo' IER; DET 07-01 G42-070-197; CLLEARWRE; UP 07-06 +42-070-197; C:LEARWRE; UP 07-011 N00j*40E -CLERK'S FILING FE GENL 0010 (.$38) Project Number 0510-092-022; KAPStkl Y4AGNER; DET 07-01 042-070-197: CLEr9FWRE; UP 07-05 042-07()-197; CLEARWRE; UP 07-06 7uQo�- �'�'a• AGRICUL T URE AG FEE 0010 Proieci Number _ 05"92-022; KAREr�l'fVF\G1dER; DET 07-01 042-070-157; CLEAWIRE; UP 07-06 042-070-i-97; CLEAR0ARE; UP 07 -OE, $ .4.00 $ 119.04 $ 227 96 470001 46123.19 3179009 Amount of Fee $ 36.00 , $ 12.36 $ 23.65 <<Fs: lri1 4912200 ia10D1 Amount of Fee $ 32��50 $ 11 15 $ 21.35 72.00 615.00 TOTAL 5,039.00 f (�' 1> 1 ea � APPROVEL? BY: vECcIVe=B BY: AUDI T OR-COI'dTt9OLLERi TREASURER i I COUNTY OF BUTTE OFFICE OF PLANNING DEPARTMENT 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA 95965-3397 RETURN SERVICE REQUESTED GN W y 0:u) co IL 012HI6205578 $00-371 11/13/2006 = Mailed From 95965 US POSTAGE PUBLIC 4 STANDLEY PATRICIA A � . 1128 WALNUT GLEN CT HEARING o �� 40 i� CHICO CA 95926 NOTICE � ~ � S rok?q � 218 9-57 N1 :1, 3085 C. 21RE:.TURN TO R. STANDLEYIPATTYEA 2952 PENNYROYAL OR CHTCO CA 9592e-4102 RETURN TO SENDER `���. I l �. 0 PROJECT COORDINATION FORM DATE of IDR: September 27, 2006 PLANNER: Chris Tolley PROJ. NAME: Clearwire LLC PROJ. NUMBER: UP 07-06 TYPE: Project Evaluation and Completeness of Application APN: 042-070-197 DEPARTMENT PLANNING PUBLIC WORKS k'o ("Z) ,, r,,� COMMENTS READY FOR HEARING? ,,:,, c.e --- W/ f-; 7, ENVIRONMENTAL HEALTH V/, COUNTY COUNSEL AG. C, BUILDING ASSESSOR V, " 15f ve-S FIRE K:/IDR Agendas/Project Coordination Form.doc PROJECT COORDINATION FORM DATE of IDR: T Z? PLANNER: 6.1Tb 1 PROJ. NAME: PROJ. NUMBER: (AP_06 TYPE: Gd GGGG`fn APN: dq 2 - D 7v DEPARTMENT COMMENTS PLANNING PUBLIC WORKS 60mw,1C-71gT? ENVIRONMENTAL HEALTH GGra,.,, 6AA rl koo ("uvtv � 0Nvrrl- tea` a COUNTY COUNSEL AG. Cvk.w—i7.M 3 C6yv"ril� BUILDING FIRE (ow�ArNff i C60,0rlOA1 f READY FOR HEARING? K:\Planning\IDR Agenda\2006 IDR Agendas\PROJECT COORDINATION FORM.doc COUNTY OF BUTTE OFFICE OF PLANNING DEPARTMENT 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA 95965-3397 to -0 L� RETURN SERVICE REQUESTED PUBLIC HEARING NOTICE 012H16205578 $00.371 11/13/2006 Mailed From 95965 US POSTAGE M 2E: JIMENEZ BEVERLY R TRUSTCD . r < o tx 264 AUTUMN GOLD DR tV o C hb as z� CHICO CA 95973 H4 o vt' NIXIE 9S7 1 21 11/25/06 �3 C" RETURN TO SENDER NOT DEL2VERABLE AS ADDRESSED UNABLE TO FORWARD BC: 95965339799 *2472-13011-18-28 I,,,111111I1,,Il,,,1)1)1)11,,,I1)1,1IM11)11 Butte County DejOrtment of Development �f Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile September 22, 2006 To: Inter -Departmental Review Committee Subject: Evaluation and Completeness of Application Applicant: Clearwire LLC,, UP 07-06 Planner: Chris Tolley APN: 072-070-197 Location: on the north side of West East Ave., 1300' (0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) 30 -Day Complete 10/6/2006 Date of IDR 9/27/2006 This application is being provided to you for comments. Please see attached documents. A hard copy of the application, including maps, has been sent to Environmental Health, Building Manager, LAFCo, Agricultural Commission, Public Works, Assessor, and CDF. All Environmental Health correspondence is routed through Karen Frederick at 7 County Center Drive. The purpose of this notice is to give you the opportunity to comment on the completeness of this application electronically to the planner, so that preparations can be made for the IDR meeting on 9/27/2006. Do you find this application complete? ❑ NO. Please respond prior to or at the IDR meeting09/25/06, regarding completeness of application. What is needed to make the application complete? X YES. My Department's conditions and/or mitigation measures are attached or will be provided at the IDR meeting. If conditions cannot be provided at or prior to the IDR meeting they must be provided no more than 1 week after the meeting. Standard Conditions are attached for your convenience. (PLEASE SEND YOUR RESPONSE TO: Signature: Darren Read Date: 9/13/06 K:/Planning/Projects/A New File/IDR Memos/IDR Completeness 8/30/05 ctol leyctol ley@buttecounty.net). Department: CDF • BUTTE COUNTY • STANDARD CONDITIONS FOR USE PERMIT APPLICANT Clearwire LLC, DATE: 9/7/2006 AGENT: Epic Wireless/ David Wiltsee APN: 072-070-197 FILE #: UP 07-06 PLANNER: Chris Tolley PROJECT DESCRIPTION: Use Permit to collocate five panel antennas and four microwave dishes at the 113' height on an existing 130' lattice tower. Additionally, ground equipment including radio cabinet & GPS antenna within the existing compound. Those items checked are conditions of approval. PLEASE CONTACT THE BUTTE COUNTY FIRE DEPARTMENT FOR COMPLIANCE WITH THE FOLLOWING CHECKED CONDITIONS: J. FIRE CLEARANCE ❑ 1. Construction, installation or development of buildings and/or roads, driveways, gates and bridges on parcels/lots shall comply with the latest California Fire Safe Regulations—Public Resources Code 4290, 4291 and current Butte County Improvement Standards, whichever is stricter. ❑ 2. Prior to construction, a pressurized community water system for fire protection is required. Bonding may be allowed with the approval of the County Fire Chief. Average required hydrant spacing is feet, hydrant size inches, and residual fire flow of GPM. Fire hydrant identification, road reflectors or post reflectors acceptable to the County Fire Chief shall be installed or bonded, prior to Parcel or Final map recordation. Submit plans to the Fire Department for review and approval prior to construction. ❑ 3. Place a note on a separate document and recorded concurrently with the Parcel, Final map or an additional map sheet stating that "Fire suppression sprinkler systems shall be installed in all new residential dwellings in accordance with NFPA Standard 13D, unless a pressurized community water system with hydrants that meet Fire Department specifications serves the property." A note stating "Automatic Fire Sprinklers conforming to NFPA Standard 13D required" is to be added to all affected building plans. ❑ 4. In lieu of hydrant installation, prior to recordation of the Parcel or Final map, payment shall be made into the hydrant fund at the current rate per lineal foot of street frontage. X 5. Prior to building construction, provide an all weather access of at least 10 feet wide and vertical clearance of 15 feet that will allow for ingress and egress and accommodate a 40,000 -pound fire apparatus to within 150 feet of all structures. ❑ 6. Place a note on a separate document, which is to be recorded concurrently with the Parcel or Final map, or on an additional map sheet stating, "Building identification and/or addresses shall be installed in conformance with Public Resources Code 4290 and shall be posted at the time of permit issuance and maintained continuously thereafter. Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile September 22, 2006 To: Inter -Departmental Review Committee Subject: Evaluation and Completeness of Application Applicant: Clearwire LLC,, UP 07-06 Planner: Chris Tolley APN: 072-070-197 Location: on the north side of West East Ave., 1300' (0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) 30 -Day Complete 10/6/2006 Date of IDR 9/27/2006 This application is being provided to you for comments. Please see attached documents. A hard copy of the application, including .maps, has been sent to Environmental Health, Building Manager, LAFCo, Agricultural Commission, Public Works, Assessor, and CDF. All Environmental Health correspondence is routed through Karen Frederick at 7 County Center Drive. The purpose of this notice is to give you the opportunity to comment on the completeness of this application electronically to the planner, so that preparations can be made for the IDR meeting on 9/27/2006. Do you find this application complete? X Yes. Conditions and/or mitigation measures are attached or will be provided at the IDR meeting. No apparent adverse agricultural issues, no other conditions or mitigating measures. Signature: !Wert C. ?fill (Depot yAA. Commissioner Department: Agriculture Date: September 11, 2006 K:/Planning/Projects/A New File/IDR Memos/1DR Completeness 8/30/05 • • Page 1 of 1 Tolley, Chris From: Bottenfield, Cliff Sent: Friday, September 15, 2006 10:36 AM To: Tolley, Chris Subject: Use Permit Applicant: Clearwire LLC UP 07-06 Location: West East Ave. APN 42-070-197 Good morning Chris, The EHD fines the application complete with no conditions. WMIXIIIIII Butte County Dertment of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile September 22, 2006 To: Inter -Departmental Review Committee Subject: Evaluation and Completeness of Application Applicant: Clearwire LLC,, UP 07-06 Planner: Chris Tolley APN: 072-070-197 Location: on the north side of West East Ave., 1300' (0.25 miles) northeast of the Hwy. 32 - West East Ave. intersection (1110 West East Ave., Chico) 30 -Day Complete 10/6/2006 Date of IDR 9/27/2006 This application is being provided to you for comments. Please see attached documents. A hard copy of the application, including maps, has been sent to Environmental Health, Building Manager, LAFCo, Agricultural Commission, Public Works, Assessor, and CDF. All Environmental Health correspondence is routed through Karen Frederick at 7 County Center Drive. The purpose of this notice is to give you the opportunity to comment on the completeness of this application electronically to the planner, so that preparations can be made for the IDR meeting on 9/27/2006. Do you find this application complete? ❑ NO. Please respond prior to or at the IDR meeting09/25/06, regarding completeness of application. What is needed to make the application complete? ® YES. My Department's conditions and/or mitigation measures are attached or will be provided at the IDR meeting. If conditions cannot be provided at or prior to the IDR meeting they must be provided no more than 1 week after the meeting. Standard Conditions are attached for your convenience. No. Comments (PLEASE SEND YOUR RESPONSE TO: Signature: Eric Schroth Date: 9/15/06 ctolleyctolley@buttecounty.net). Department: Public Works - County of Butte KIPlanning/Projects/A New File/IDR Memos/IDR Completeness 8/30/05 Wednesday, August 16, 2006 Development Services PLANNING DIVISION ver. 1.0 '. i Counte r CPT Payment Date 8/16/2006 Receipt Number 456688 Received From Clearwire ALUC (Airport Land Use) Public Works, (Land Development) Applicant Clearwire Application Number UP 07-06 or In Reference To Parcel Number ;042-070-197 Check Number/ 33189 Cash Total..Received Total Fees $2332.50 I! DDS Planning (General Fund) $1,951.14 ALUC (Airport Land Use) Public Works, (Land Development) $108.40 Environmental Health $0.00 $0.00 CDF (Fire Department) $227.96 NOD / NOE (Recording Fee) $23.65 Aunt Minnie $1, 500 or $2,000 $0.00 Planning Review /.EIR $0.00 Fish/Game $0.00 ALUC (Airport Land Use) $0.00 $0.00 Non Sufficient Funds ($25.00 Fee) Cell Tower ($2500.00) $0.00 Public Sales / Copies $0.00 Other: $21.35 Wednesday, August 16, 2006 Development Services PLANNING DIVISION ver. 1.0 Counte r iCPT FPayment Date 8/16/2006 Receipt Number X456687 Received From 'Clearwire i •ALUC (Airport Land Use). Public Works (Land Development) Applicant Clearwire LLC j Application Number UP 07-06 or In Reference To Parcel Number !042-070-197 Check Number/ 36269 Cash Total�Received; E:$,1,218.00 Total+ees- $1 , 218.00 4fy DDS Planning - (General Fund) $1,018.86 i •ALUC (Airport Land Use). Public Works (Land Development) $56.60 Environmental Health $0.00 i i $0.00 CDF (Fire Department) $119.04 NOD / NOE (Recording Fee) $12.35 Aunt Minnie $1, 500 or $2,000 $0.00 i Planning Review / EIR $0.00 Fish /Game $0.00 •ALUC (Airport Land Use). $0.00 $0.00 Non Sufficient Funds ($25.00 Fee) Cell Tower ($2500.00) $0.00 Public Sales /Copies $0.00 i Other: $11.15 • COUNTY OF BUTTE 4.56687 OFFICIAL RECEIPT f I'-- / OFFICE OR DE ARTMENT ISSUING RECEIPT /6 _2V6 Received from The Sum ofja/ 1�.�/ ca„�/�21Z For -, v b Received: �ya a7D —143 Received B Q' CASH ❑ CHECK &3- By DAVCO BUSINESS FORMS • (530) 743-8511 Form 88887 . , O C mO O" . • c cn z co co 0 W ❑ OD .03 o m m C1 G c v Ozm T a m r c Z v n m Jr m rn G p Aj ua �D V as'M 00 N & 00 EAST AVE./T.MOBILE CA-CHCO I I PROJECT DESCRIPTIONS 5508 LAKE WASHINGTON BLVD, SUITE 300 KIRKLAND, WA 98033 PROJECT TEAM DRIVING DIRECTIONS –FROM FOLSOM, CA, TAKE BARTON ROAD NORTH VICINITY MAP DRAWING INDEX ' CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE CONTENTS ADDITION OF (8) ANTENNAS (FOUR (4) PANEL & FOUR (4) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. TITLE SHEET AND GENERAL INFORMATION SITE INFORMATION PROJECT CONTACTS SITE ADDRESS: 1110 W. EAST ROAD ARCHITECT/ SAM LAMENDOLA GENERAL NOTES CHICO, CA 95926 ENGINEERING: MAX ENGINEERING, LLC SITE PLAN –TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND 9000 SOUTHWEST FREEWAY ENLARGED SITE PLAN AND SOUTH ATC SITE#: CA–CHC011 SUITE #410 ELEVATION –SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX HOUSTON, TX 77074 EQUIPMENT DETAILS PARCEL NUMBER: 042-070-197 MOBILE: (717) 873-0466 �� LATITUDE: 39' 44' 45.5" N GENERAL CONTACT: DAVID WILTSEE ANTENNA DETAILS –EXIT INTO SR 149 AND GO APPROX. 4.6 MILES EPIC WIRELESS GROUP n 0 381 SOUTH LEXINGTON DR. GROUNDING PLAN AND DETAILS LONGITUDE: 121' 52' 56.1" W SUITE #103 –TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO FOLSOM, CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (530) 878-9117 dwiltsee®sbcglobol.net 0 ELEVATION: 167' AMSL SITE OWNER: T -MOBILE CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF TELECOMMUNICATIONS PHONE: (425) 398-7550 FACILITY V PROPERTY OWNER: LELAND STANDFORD MASONIC PROPOSED USE: TELECOMMUNICATIONS TEMPLE ASSOCIATION rr FACILITY P.O. BOX 784 CHICO. CA. 95927 POWER: PG & E PHONE: (530) 342-7143 TELCO: AT&T TE BUTTE COUNTY JURISDICTION: BUTTE COUNTY ZONING: A-5 AGRICULTURE SEP 0 7 21 u6 0 APPLICABLE CODE: 2001 CALIFORNIA BUILDING STANDARDS CODE DEVELOMAIL, NT C) SERVICES CONSTRUCTION TYPE: V -N OCCUPANCY TYPE: UNOCCUPIED cr PROJECT AREA: 49 SO. FT. 5508 LAKE WASHINGTON BLVD, SUITE 300 KIRKLAND, WA 98033 PROJECT TEAM DRIVING DIRECTIONS –FROM FOLSOM, CA, TAKE BARTON ROAD NORTH VICINITY MAP DRAWING INDEX ' SHEET CONTENTS –TURN LEFT (WEST) ON ROCKLIN ROAD T-1 TITLE SHEET AND GENERAL INFORMATION –TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES G-1 GENERAL NOTES –TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES A-1 SITE PLAN –TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND A-2 ENLARGED SITE PLAN AND SOUTH GO 20 MILES. ELEVATION –SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX A-3 EQUIPMENT DETAILS 37 MILES U �� A-4 ANTENNA DETAILS –EXIT INTO SR 149 AND GO APPROX. 4.6 MILES n 0 E-1 GROUNDING PLAN AND DETAILS –MERGED INTO SR99, GO APPROX. 13 MILES. –TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO z APPROX. 1.8 MILES . –SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND I W. EAST AVE. ® MAX ENGINEERING, LLC . ®® To ® loMobile 0 9000 SW FREEWAY, Ste • 410 EPIC V/IRELEsS GROUP, INC. Houston, Texas 77074 19807 N. CREEK PARKWAY N. Phone (713) 773-2525 381 5. LEXINGTON DR. SUITE #103 BOTHEL, WA 98011 Fax (713) 773-2558 FOi-SOM, CA 95630 At all new services & grounding trenches, provide "WARNING' tope of 12" below grod j "CALL BEFORE YOU DIG' 1-800-227-2600 CALIFORNIA UNDERGROUND SERVICE ALERT NORTH THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. UP C>(o - clearw"re° 5808 LAKE WASHINGTON BLVD HE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 8000 8W FREEWAY. Ste • 41D Houston, Texas 77074 Phone (713) 773-2626 Fax 1713) 773-2668' EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SUITE /103 FOLSOM. CA 95630 TITLE SHEET AND GENERAL INFORMATION REVISION 0 0 0 I \ C �1 O `/ I p o m N tY rn a 3 O 0 W U �� TITLE SHEET AND GENERAL INFORMATION REVISION 0 0 \ n 0 z 0 V rr z Z 0 C) 7� cr 0 Lc] 0 a o N N 0 TITLE SHEET AND GENERAL INFORMATION REVISION 0 .,1 GENERAL NOTES: ABBREVIATIONS: D clearw're° 5606 LAKE WASKNGTON BLVD NE SUITE #300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste • CD Houston, Texas 77074 Phone 17131 773-2626 • Fax (719) 773-2668 ,641-1 _ EPIC WIRELESS OROLIP. 381 S. LEXINGTON DR. SUITE #103 FOLSOM, CA 95630 w ADJ ADJUSTABLE 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING & AND SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, IMPROVEMENTS, EASEMENTS, PAVING, CURBING. -ETC. DURING CONSTRUCTION. UPON APPROX APPROXIMATE UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE O BTS AT BASE TRANSMISSION STATION INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. CAB CABINET O j `J DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS W CLG CEILING AND OWNER'S PROJECT MANUAL. 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONIC CONT CONCRETE CONTINUOUS 0 CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. DIA OR DIAMETER 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR DWG DRAWING WATER OR SEWER SERVICE. OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EA EACH 0 EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ELEC ELEV ELECTRICAL ELEVATION 3. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER.SHALL BEAR THE ED EQUAL HANDICAP ACCESS IS REQUIRED). RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY EQUIP EQUIPMENT CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S EGB - EQUIPMENT GROUND BAR 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND PROPOSAL IN THE EVENT OF DISCREPANCIES 'THE CONTRACTOR SHALL PRICE THE (E) EXISTING DRAWINGS PROVIDED, BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. EXT EXTERIOR SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARWIRE, LLC. FF FINISHED FLOOR STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY GA GAUGE THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO GALV GALVANIZED MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED T0, AND AVOID DISTURBING NORMAL BUSINESS. GC GENERAL CONTRACTOR APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH GRND GROUND CONSTRUCTION. LG LONG 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR MAX MAXIMUM UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. MECH MECHANICAL .MFR MANUFACTURER 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE w MGB MASTER GROUND BAR CONSTRUCTION OPERATION. MIN MINIMUM MTL METAL 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND NIC NOT IN CONTRACT NOT SCALE INSPECTIONS REQUIRED FOR CONSTRUCTION. NTS OC ON CENTER E OPP OPPOSITE 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY PCS PERSONAL COMMUNICATION SYSTEM BASIS. SF SQUARE FOOT SHT SHEET SIM SIMILAR 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SS STAINLESS ,STEEL SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED STL STEEL PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE TOC TOP OF CONCRETE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELDCONDITIONS AND CONFIRM TOM TOP OF MASONRY THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH TYP VIF TYPICAL VERIFY IN FIELD CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO LION UNLESS OTHERWISE NOTED THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. WWF WELDED WIRE.FABRIC W/ WITH 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12• ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT t TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. D clearw're° 5606 LAKE WASKNGTON BLVD NE SUITE #300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste • CD Houston, Texas 77074 Phone 17131 773-2626 • Fax (719) 773-2668 ,641-1 _ EPIC WIRELESS OROLIP. 381 S. LEXINGTON DR. SUITE #103 FOLSOM, CA 95630 w I� 0 0 I n O j `J o <c K 0) rn a U 3 O U W U �3: G-1 GENERAL NOTES REVISION 1 0 0 n n 0 z 0 U rr V) z o 0 " D: o. LL3 w V) V) 0 G-1 GENERAL NOTES REVISION 1 0 ADJACENT ZONING ZONE: AR—AGRICULTURAL RESIDENTIAL BUTTE COUNTY ADJACENT ZONING ZONE: A-5 AGRICULTURAL BUTTE COUNTY SITE PLAN ZONE: AR -AG. RES. I I ZONE: AR -AG. RES. ZONE: AR -AG. RES. I I ZONE: R4 BUTTE COUNTY I I BUTTE COUNTYI BUTTE COUNTY I IRESIDENTIAL TOWNHOUSES I I BUTTE COUNTYLij I I I — -- -- -- I -- -- ZONE: R4 I > I I I RESIDENTIAL TOWNHOUSES I Q I ZONE: AR -AG. RES. \ ZONE: AR -AG. RES. ZONE: AR -AG. RES. \ BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY QI W ZONE: AR—AG. RES. I ZONE: AR—AG. RES. ZONE: AR—AG. RES. I ZONE: R4 — _ IRESIDENTIAL TOWNHOUSES BUTTE COUNTY — BUTTE COUNTY BUTTE COUNTY — _ _ _ _ JBUTTE COUNTY I IPROPERTY LINE 656'—r ZEXIST L LEGAL DESCPRIPTION: I + + LANDSCAPING? ALL THAT CERTAIN REAL PROPERTY I v SITUATE IN THE STATE OF CAUFORNL4, �^,1 i.l CITY OF CHICO. DESCRIBED n AS FOLLOWS: W z TAX PARCEL ID:I J I ADJACENT ZONING Di AWP 42. LOT 197. BLOCK 07 Z EXISTING W I ZONE: S—R-1/2 SUBURBAN RESIDENTIAL o I BUTTE COUNTY MASONIC a cr a EXISTING 130(1) T- TEMPLE cm 0 C-4 cr(MOBILE LATTICE TOWER NIN I a SITE ENTRY IL W/ PROPOSED - j ZONE: A-5 AGRICULTURAL C/ (ANTENNAS BUTTE COUNTY 1 1 A II ADJACENT ZONING ZONE: S—R-1/2 SUBURBAN RESIDENTIAL bI BUTTE COUNTY EXIST. ZPARKING I EXISTING LOT 7 I GARAGE I 1 1 N PROPERTY UNE 666' 1 57'-7" 601'-T± \ \ \ \ A LEASE AREA EXISTING \ I LANDSCAPING ADJACENT ZONING ZONE: A-5 AGRICULTURAL \ BUTTE COUNTY NORD AVE. SCALE: 1" = 50'-0" (24x36 SIZE) SCALE: 1" = 100'-0" (11x17 SIZE) 1 clear'w're° 5806 LAKE WASMNGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY. Ste •IID Houston. Texaa 77074 Phone (718) 779-2525 Fax (719) 773-2668 E•C WIRELESS GRDUP. 381 S. LEXINGTON DR. SURE /103 FOLSOM. CA 95630 A-1 SITE PLAN REVISION 0 1- 0 L� O o f 1 Q N O) z Q I � 0 3 06 U U A-1 SITE PLAN REVISION 0 0 n n 0 z 0 U z O L' 0 Lc] w � o rn fn 0 A-1 SITE PLAN REVISION 0 EXISTING 4' /� WIDE MAN /' + GATE. x— x— x— x— x� �. EXISTING L I COAX . e _ SHROUD ` ' •.e ZEXfSi. x CONC. x W o SLAB o 440 I 1 ' U ` ' 2 I 1J 4 O Z V1 X W x W is I a. b�0d7 x1-4 I I i x— x x— x EXISTING UTILITY H -FRAME EXISTING EQUIPMENT CABINETS (BY OTHEF ENLARGED SITE PLAN EXISTING 6' HIGH CHAIN- LINK FENCE W/3 STRANDS OF BARBED WIRE. EXISTING 130'(1) T -MOBILE LATTICE TOWER W/ PROPOSED CLFARWIRE 1 (4) SECTOR ANTENNA A-4 ARRAY & (4) MICROWAVE ANTENNA. SEE NOTE BELOW PROPOSED CLEARWIRE COAX 2' CABLE CONDUR W/ SHROLIT RUN ON CONC. SLAB. PROPOSED CLEARWIRE e CABINET ON EXISTING CONCRETE SLAB A-3 T-0" CLEARWIRE AND ELEVATION LEASE AREA 0 EXISTING FENCED AREA NOTE: LOCATE MW ANTENNAS I I -I 1' MW DISH AZI O 16' 2' MW DISH AZI ® 89' 1' MW DISH AZI O 131' 2' MW DISH AZI ® 268'. SEE DTL 6/A-4 FOR ANTENNA ORIENTATION SCALE: 1/4" = 1'-0" (24x36 SIZE) I I WEST ELEVATION SCALE: 1/8" = 1'-0" (11x17 SIZE EXISTING EQUIPMENT EXISTING OMNI ANTENNAS EXISTING MW DISH ANTENNA EXISTING PANEL ANTENNAS PROPOSED CLEARWIRE (4) 16 SECTOR ANTElM ARRAY W/1.6 RMJRE, RC O 113' (t) 4 PROPOSED (4) CLEARWW t 6 MICROWAVE ANTENNAS O _4 110' (t) EXISTING 130'(±) T -MOBILE LATTICE TOWER (DESIGNED BY OTHERS) • EXISTING FIR TREE • EXISTING GARAGE (BEYOND SITE) PROPOSEDCLEARYYIRE e CABINET ON EXISTING A_3 CONCRETE SLAB NEW GPS ANTENNA MOUNTED e ON EXISTING CONCRETE SLAB E-1 EXISTING 6' HIGH CHAIN- LINK FENCE WITH (3) STRAND BARBED WIRE EXISTING UTILITY H -FRAME EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) 2 SCALE: 1/16" = 1'-0" (11x17 SIZE) clearw0rel 5808 LAKE wASHENGTON BLVD NE SUITE /300 KIRKLAND, WA 98033 MAX ENGINEERING, LLC 8000 SW FREEWAY, Ste • 410 Houston, Texaa 77074 Phone MM 773-2525 Fax 17131773-2568 0 . EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SURE 1103 FOLSOM. CA 95630 W ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 I I -I � I 0: N H N a � i o � A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 0 z 0 U �N ZU O Ix 0 Lc] w � o N N 0 A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 /40 It I * EAST AV.E*./.T'MOB ILE CA-CHC011 PROJECT DESCRIPTIONS CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (8) ANTENNAS (FOUR (4) PANEL & FOUR (4) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. SITE INFORMATION PROJECT CONTACTS SITE ADDRESS: 1110 W. EAST ROAD ARCHITECT/ SAM LAMENDOLA CHICO, CA 95926 ENGINEERING: MAX ENGINEERING, LLC ELEVATION 9000 SOUTHWEST FREEWAY ATC SITE#: CA—CHC011 SUITE #410 ANTENNA DETAILS HOUSTON, TX 77074 PARCEL NUMBER: 042-070-197 MOBILE: (717) 873-0466 LATITUDE: 39' 44' 45.5" N GENERAL CONTACT: DAVID WILTSEE EPIC WIRELESS GROUP 381 SOUTH LEXINGTON DR. LONGITUDE: 121' 52' 56.1" W SUITE #103 FOLSOM, CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (530) 878-9117 dwiltsee®sbcglobal.net ELEVATION: 167' AMSL SITE OWNER: T—MOBILE CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF TELECOMMUNICATIONS PHONE: (425) 398-7550 FACILITY z PROPERTY OWNER: LELAND STANDFORD MASONIC PROPOSED USE: TELECOMMUNICATIONS TEMPLE ASSOCIATION FACILITY P.O. BOX 784 CHICO. CA. 95927 POWER: PG & E PHONE: (530) 342-7143 TELCO: AT&T BUTTE COUNTY JURISDICTION: BUTTE COUNTY ZONING: A-5 AGRICULTURE SEP U 7 2006 / i3iJU APPLICABLE CODE: 2001 CALIFORNIA BUILDING STANDARDS CODE_ DEVELOPMENT SERVICES CONSTRUCTION TYPE: V -N OCCUPANCY TYPE: UNOCCUPIED PROJECT AREA: 49 SQ. FT. 5508 LAKE WASHINGTON BLVD SUITE 300 KIRKLAND, WA 98033 VICINITY MAP yam• .. �y�r U .. � 'r SITE DRIVING DIRECTIONS j —FROM FOLSOM, CA, TAKE BARTON ROAD NORTH I —TURN. LEFT (WEST) ON ROCKLIN ROAD —TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES —TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES —TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND i GO 20 MILES. ' —SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX 37 MILES i —EXIT INTO SR 149 AND GO APPROX. 4.6 MILES —MERGED INTO SR99, GO APPROX. 13 MILES. —TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO APPROX. 1.8 MILES —SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. t PROJECT TEAM 1 f ® WMAX ENGINEERING, LLC ®m ® ®®® ISI®b�l� ° T 9000 SW FREEWAY, Ste • 410 EPIC WIhELES5 GROUP, INC. Houston, Texas 77074 Phone (713) 773-2525 381 S. LEXINGTON DR. 19807 N. CREEK PARKWAY N. SUITE #103 BOTHEL, WA 98011 Fax (713) 773-2558 FOLSOM, CA 95630 CONTENTS v 3 I I GENERAL NOTES DRIVING DIRECTIONS j —FROM FOLSOM, CA, TAKE BARTON ROAD NORTH I —TURN. LEFT (WEST) ON ROCKLIN ROAD —TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES —TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES —TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND i GO 20 MILES. ' —SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX 37 MILES i —EXIT INTO SR 149 AND GO APPROX. 4.6 MILES —MERGED INTO SR99, GO APPROX. 13 MILES. —TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO APPROX. 1.8 MILES —SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. t PROJECT TEAM 1 f ® WMAX ENGINEERING, LLC ®m ® ®®® ISI®b�l� ° T 9000 SW FREEWAY, Ste • 410 EPIC WIhELES5 GROUP, INC. Houston, Texas 77074 Phone (713) 773-2525 381 S. LEXINGTON DR. 19807 N. CREEK PARKWAY N. SUITE #103 BOTHEL, WA 98011 Fax (713) 773-2558 FOLSOM, CA 95630 SHEET CONTENTS T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN AND SOUTH ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS E-1 GROUNDING PLAN AND DETAILS DRAWING INDEX SHEET CONTENTS T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN AND SOUTH ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS E-1 GROUNDING PLAN AND DETAILS At all new services & grounding trenches, provide °WARNING" tape of 12" below grad �j "CALL BEFORE YOU DIG" 1-800-227-2600 CALIFORNIA UNDERGROUND SERVICE ALERT NORTH THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. clearw're® 5808 LAKE WASHNGTON BLVD NE SUITE 1300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 8000 SW FREEWAY, Ste • 410 Houston, Texas 77074 Phone 0131 775-2525 Fax 0191 773-2568 fl - EPIC WIRELESS GROUP, INC. 381 S. LEXINGTON DR. SUITE 1103 FOLSOM. CA 95630 T-.1 TITLE SHEET AND GENERAL INFORMATION REVISION 0 UDI 50 F� I 0 > � O / \ �/ I o m 0: N rn a L) 3 U T-.1 TITLE SHEET AND GENERAL INFORMATION REVISION 0 UDI 0 n 0 z 0 U z O " 0 0 T-.1 TITLE SHEET AND GENERAL INFORMATION REVISION 0 GENERAL NOTES:. " M 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF. WORK .SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 3. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARWIRE, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE -BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED T0, AND w APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13, THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE—RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2—A OR 2—A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED'DUE TO- CONSTRUCTION ON OR ABOUT THE PROPERTY. 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES. THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. 6 0 ABBREVIATIONS: - ADJ ADJUSTABLE & AND APPROX APPROXIMATE p AT BTS BASE TRANSMISSION STATION CAB CABINET CLG CEILING CONC CONCRETE CONT CONTINUOUS DIA ORO DIAMETER DWG DRAWING EA EACH ELEC ELECTRICAL ELEV ELEVATION EO EQUAL EQUIP EQUIPMENT EGB EQUIPMENT GROUND BAR - (E) EXISTING EXT EXTERIOR FF FINISHED FLOOR GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GRND GROUND LG LONG MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MGB MASTER GROUND BAR MIN MINIMUM MTL METAL NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OPP OPPOSITE PCS PERSONAL COMMUNICATION SYSTEM SF SQUARE FOOT SHT SHEET SIM SIMILAR SS STAINLESS STEEL STL STEEL TOC TOP OF CONCRETE TOM TOP OF MASONRY TYP TYPICAL VIF VERIFY IN FIELD LION UNLESS OTHERWISE NOTED WWF WELDED WIRE FABRIC W/ WITH clearw're° 5808 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. INA 98033 MAX ENGINEERING, LLC 0000 SW FREEWAY, Ste • IM Houston, Texas 77074 Phone (71s) 778-2526 Fax (719) 775-2568 EPIC WIRELESS GROUP. INC 381 S. LEXINGTON DR. SUITE /103 FOLSOM. CA 95630 G-1 GENERAL NOTES REVISION 0 0 0 n 0 I O 1 `! I o � 4' N rn In � 00 U G-1 GENERAL NOTES REVISION 0 0 0 n 0 z 0 V u) z O 0 F, cy 0 w � V) m 0 G-1 GENERAL NOTES REVISION 0 r SITE PLAN ZONE: AR -AG. RES. I I ZONE: AR -AG. RES. ZONE: AR -AG. RES. I I ZONE: R4 BUTTE COUNTY I I BUTTE COUNTY. I BUTTE COUNTY I I RESIDENTIAL TOWNHOUSES I I I BUTTE COUNTY I ADJACENTZONIN Z ZONE:NE:AR-AGRICULTURAL I ' RESIDENTIAL - - - BUTTE COUNTY ZONE: R4 > I I RESIDENTIAL TOWNHOUSES I Q I RES. i ^ Y ` ?URES. I RZONE: AR -AG. ES. BUTTE COUNTY BUTTE COUNTY TTE COUNTYBUTTE COUNTY ADJACENT ZONING ZONE: A-5 AGRICULTURAL BUTTE COUNTY LEASE AREA \ \ \ \ EXISTING \ I + ' LANDSCAPING ADJACENT ZONING ZONE: A-5 AGRICULTURAL \ BUTTE COUNTY, NORD AVE. SCALE: 1"= 50'-0" (24x36 SIZE) SCALE: 1" = 100'-0" (11x17 SIZE) clearw're° 58DB LAKE WASKNGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste • 00 Houston Texas 77074 Phone 17134) 773-2626 Fax (713) 773-2668 fl - EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SUITE /103 FOLSOM, G 95630 Q ' ZONE: AR -AG. RES. BUTTE COUNTY I ZONE: AR -AG. RES. i ZONE: AR -AG. RES. (ZONE: R4 ` BUTTE COUNTY BUTTE COUNTY IRESIDENTIAL TOWNHOUSES LLI 0 0 JBUTTE COUNTY PROPERTY LINE 656'-7- co u U I o Ic cr" CD00 U ; 00 W U �ILI) EXIST LEGAL DESCPRIPTIOW 1 + +1 LANDSCAPING ALL THAT CERTAIN REAL PROPERTY " 0 SITUATE IN THE STATE OF CALIFORNIA, eel CITY OF CHICO, DESCRIBED ( n I AS FOLLOWS: w V) 1 J � z z z TAX PARCEL ID: 1 ZONING 0 MAP 42. LOT 197, BLOCK 07 or ZONE S -R-1/2 SUBURBAN RESIDENTIAL ZONE- S Ln O 0 EXISTING > a BUTTE COUNTY H 'a or a DWI= 130' ) T- W TEMPLE ONIC I � C' or WWX LATTI TOWER NIN l a SITE ENTRY 0. W/CLEARMFtE PRDPOSED N j ZONE: A-5 AGRICULTURAL 0 BUTTE COUNTY - - - - - - - - - - (ANTENNAS 1 ( 1 A 1 ADJACENT ZONING EXIST.Z ZONE: S -R-1/2 SUBURBAN RESIDENTIAL BUTTE COUNTY 1 PARKING EXISTING LOT7 1 I o I GARAGE 1 I z 1 1 N - - - - - - - PROPERTY LINE 666' (+/-) 57'-7" 601'-8't 1 L I LEASE AREA \ \ \ \ EXISTING \ I + ' LANDSCAPING ADJACENT ZONING ZONE: A-5 AGRICULTURAL \ BUTTE COUNTY, NORD AVE. SCALE: 1"= 50'-0" (24x36 SIZE) SCALE: 1" = 100'-0" (11x17 SIZE) clearw're° 58DB LAKE WASKNGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste • 00 Houston Texas 77074 Phone 17134) 773-2626 Fax (713) 773-2668 fl - EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SUITE /103 FOLSOM, G 95630 A -1 - SITE PLAN REVISION 0 0 0 I co u U I o Ic cr" CD00 U ; 00 W U �ILI) A -1 - SITE PLAN REVISION 0 0 0 z 0 or orU V) � z z 0 Ln O 0 > U. Lj W a N 0 A -1 - SITE PLAN REVISION 0 EXISTING 4' WIDE MAN �/ + GATE. x—x—x—x=x— EXISTING COAX ;.°. SHROUD D o ZEX(5T. 1 x CONC. SLAB x x— EXISTING UTILITY H–FRAME - L EXISTING EQUIPMENT CABINETS (BY OTHERS) LEASE AREA ENLARGED SITE PLAN EXISTING 6' HIGH CHAIN– LINK FENCE W/3 STRANDS OF BARBED WIRE. EXISTING 130'(±) T–MOBILE LATTICE TOWER W/ PROPOSED CLEARWIRE t (4) SECTOR ANTENNA A-4 ARRAY & (4) MICROWAVE ANTENNA. SEE NOTE BELOW PROPOSED CLEARWIRE COAX2 CABLE CONDUIT W/ SHRDUT RUN ON CONIC. SLAB. E- PROPOSEDCLEA NG e CABINET ON EXISTING CONCRETE SLAB A-3 NOTE: LOCATE MW ANTENNAS 1' MW DISH AZI O 16' 2' MW DISH AZI O 89' 1 -MW DISH AZI O 131• 2' MW DISH AZI O 265. SEE DTL 6/A-4 FOR ANTENNA ORIENTATION SCALE: 1/4" = 1'-0" (24x36 SIZE) 11 I WEST ELEVATION SCALE: 1/8" = 1'-0" (11x17 SIZE EXISTING EXISTING OMNI ANTENNAS EXISTING MW DISH ANTENNA EXISTING PANEL ANTENNAS PROPOSED CLEARWIRE (4) 1.6 SECTOR ANTENNA ARRAY W/1 FUTURE, RC O 113' (t) A-4 PROPOSED (4) CLEARWNtE t,6 MICROWAVE ANTENNAS O A-4 110' (f) 03VO qqA clearw're® 51108 LAKE WASHINGTON BLVD NE SURE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 8000 SW FREEWAY, Ste a 410 HoustoNL Teres 77074 Phone (713) 773-2626 Fax 17131773-2668 EPIC WIRELEBR GROUP, INC. 381 S. LEXINGTON DR SUITE /103 FOLSOM, CA 95630 EXISTING FIR TREE EXISTING GARAGE (BEYOND SITE) PROPOSED C=Xt0 RE 3 CABINET ON EXISTING A_3 CONCRETE SLAB NEW GPS ANTENNA MOUNTED e ON EXISTING CONCRETE SLAB E-1 EXISTING 6' HIGH CHAIN- LINK FENCE WITH (3) STRAND BARBED WIRE EXISTING UTILITY H -FRAME EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) 12 I SCALE: 1/16" = 1'-0" (11x17 SIZE ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 EXISTING 130'(±) T–MOBILE LATTICE�.at�i TOWER (DES1G1140–BY n OTHERS) df7;.�i ���.1'Q72r3 C1y866afft �, o r � i o v W L) U U EXISTING FIR TREE EXISTING GARAGE (BEYOND SITE) PROPOSED C=Xt0 RE 3 CABINET ON EXISTING A_3 CONCRETE SLAB NEW GPS ANTENNA MOUNTED e ON EXISTING CONCRETE SLAB E-1 EXISTING 6' HIGH CHAIN- LINK FENCE WITH (3) STRAND BARBED WIRE EXISTING UTILITY H -FRAME EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) 12 I SCALE: 1/16" = 1'-0" (11x17 SIZE A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 n n 0 z 0 U Ir 0 z z 0 0 0 w N N 0 A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 A 15 APPROVED Pmlopment Plan DATE USE PERMrr VARIANCE MINOR U.P. —ADM.PERMIT. V PLANNING COMMISS. PLANNING MANAGER 4w A 15 Ps' V� Lm C EAST AVE./T-MOBILE CA-CHCO I I VICINITY MAP F titi \ PROJECT TEAM dearw'reo MAX ENGINEERING, �LC 9000 SW FREEWAY, Ste 410 EPIC WIRELESS GROUP, INC. 5508 LAKE WASHINGTON BLVD, Houston, Texas 77074 381 S. LEXINGTON DR. SUITE 300 Phone (713) 773-2525 SUITE #103 KIRKLAND, WA 98033 Fax (713) 773-2558 FOLSOM, CA 95630 ' CONTENTS S* PROJECT DESCRIPTIONS G-1 GENERAL NOTES A-1 SITE PLAN - CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (8) ANTENNAS (FOUR (4) PANEL & FOUR (4) MICROWAVE) TO ANV ; • SITE - EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE EQUIPMENT DETAILS ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER.(' . E-1 GROUNDING PLAN AND- DETAILS SITE INFORMATION PROJECT CONTACTS 32 SITE ADDRESS: r 1110 W. EAST ROAD AT T RCHIEC/ SAM LAMENDOLA CHICO, CA 95926 ENGINEERING: MAX ENGINEERING, LLC' 9000 SOUTHWEST FREEWAY ds A ATC SITE#: CA—CHCOII SUITE #410 HOUSTON, TX 77074 �? ) � PARCEL NUMBER: 042-070-197 MOBILE: (717) 873-0456 0 n LATITUDE: 39' 44' 45.5" N GENERAL CONTACT: DAVID WILTSEE EPIC WIRELESS GROUP,�.. 381 SOUTH LEXINGTON DR. LONGITUDE: 121' 52' 56.1" W SUITE #103 FOLSOM, CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (530) 878-9117 DRIVING DIRECTIONS dwiltsee®sbcglobol.net ELEVATION: 167' AMSL SITE OWNER: T -MOBILE FROM FOLSOM, CA, TAKE BARTON ROAD NORTH CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF TELECOMMUNICATIONS PHONE: (425) 398-7550 -TURN LEFT (WEST) ON ROCKLIN ROAD FACILITY PROPERTY OWNER: LELAND STANDFORD MASONIC -TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND PROPOSED USE: TELECOMMUNICATIONS TEMPLE ASSOCIATION TRAVEL NORTH APPROX. 7.9 MILES FACILITY P.O. BOX 784 CHICO. CA. 95927 -TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES POWER: PG & E PHONE: (530) 342-7143 O -TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND TELCO: AT&T GO 20 MILES. JURISDICTION: BUTTE COUNTY -SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX BUTTE 37 MILES ZONING: A-5 AGRICULTURE COUNTY 0 -EXIT INTO SR 149 AND GO APPROX. 4.6 MILES APPLICABLE CODE: 2001 CALIFORNIA BUILDING STANDARDS CODE SEP 0 7 2606 -MERGED INTO SR99, GO APPROX. 13 MILES. CONSTRUCTION TYPE: V—N DEVELOPMENT -TURN LEFT (ISOUTHWEST) ONTO EAST AVENUE AND GO OCCUPANCY TYPE: UNOCCUPIED SERVICES APPILES PROJECT AREA: 49 SQ. FT. —SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. PROJECT TEAM dearw'reo MAX ENGINEERING, �LC 9000 SW FREEWAY, Ste 410 EPIC WIRELESS GROUP, INC. 5508 LAKE WASHINGTON BLVD, Houston, Texas 77074 381 S. LEXINGTON DR. SUITE 300 Phone (713) 773-2525 SUITE #103 KIRKLAND, WA 98033 Fax (713) 773-2558 FOLSOM, CA 95630 To m m Mob il� mo 19807 N. CREEK PARKWAY N. BOTHEL, WA 98011 0019 . p. DRAWING INDEX SHEET ' CONTENTS S* TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN - ;z F ELEVATION A-3 To m m Mob il� mo 19807 N. CREEK PARKWAY N. BOTHEL, WA 98011 0019 . p. DRAWING INDEX SHEET ' CONTENTS T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN AND SOUTH ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS E-1 GROUNDING PLAN AND- DETAILS At all new services & grounding trenches, provide "WARNING" tope of 12" below grod C j "CALL BEFORE YOU DIG" v 1_800_227_2600 CALIFORNIA UNDERGROUND SERVICE ALERT NORTH THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. clearw're° 5808 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 000 8SW FREEWAY, Ste • 110 77 Houetolt Texas 074 Phone (119) 773-2628 Fax 17131 773-2658 EPIC WIRELESS GRD- INC. 381 S. LEXINGTON DR. SUITE /103 FOLSOM. CA 95630 T- I TITLE SHEET AND GENERAL INFORMATION REVISION 0 0 n 0 z 0 U H- z O 0 > Lj W N N 0 T- I TITLE SHEET AND GENERAL INFORMATION REVISION 0 15;A GENERAL NOTES: - ABBREVIATIONS: 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED 'OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-AIOBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. clearw're° 5608 LAKE WASwNGTON BLVD NE SUITE 130O KIRKLAND. WA 98033 MAX ENGINEERING, LLC WW SW FREEWAY, Ste - 410 Houston, Texas 77074 Phone (713) 773-2625 Fax (713) 773-2568 EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON OR SUITE /103 FOLSOM, CA 95630 * - ADJ , ADJUSTABLE 1. DRAWINGS ARE NOT 'TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS 16: CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING & AND SET OF DOCUMENTS IS INTENDED, TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON APPROX APPROXIMATE 'AT UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE BTS B BASE TRANSMISSION STATION INCLUDE FURNISHING ALL -MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS w~ OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. CAB CABINET DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS o ci Q' N rn a U 3 o 0_ w CLG CEILING , AND OWNER'S PROJECT MANUAL. 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONC CONT CONCRETE CONTINUOUS z CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. DIA OR DIAMETER 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR DWG DRAWING WATER OR SEWER SERVICE. - OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EA EACH - EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ELEC ELEC ELECTRICAL ELEVATION 3. THE PROPOSED FACILITY' IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE EQ EQUAL HANDICAP ACCESS IS REQUIRED). RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHRECT/ENGINEER OF ANY EQUIP EQUIPMENT CONFLICTS, ERRORS. OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S EGB EQUIPMENT GROUND BAR 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE (E) EXISTING DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE EXT EXTERIOR SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARWIRE, LLC. - MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. FF FINISHED FLOOR STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY GA GAUGE THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNERS PREFERRED HOURS TO GALV GALVANIZED MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO, AND AVOID DISTURBING NORMAL BUSINESS, GC GENERAL CONTRACTOR APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH GRND GROUND CONSTRUCTION. 0 0 LG LONG 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR MAX MAXIMUM UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. MECH MECHANICAL W MFR MANUFACTURER 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE c MGB MASTER GROUND BAR CONSTRUCTION OPERATION. MIN MINIMUM MTL METAL 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND 0 NIC NOT IN CONTRACT NOT TO SCALE INSPECTIONS REQUIRED FOR CONSTRUCTION. NTS OC ON CENTER OPP OPPOSITE 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY PCS PERSONAL COMMUNICATION SYSTEM BASIS. SF SQUARE FOOT SHT SHEET SIM SIMILAR 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SS STAINLESS STEEL SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED STL STEEL PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE TOC TOP OF CONCRETE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM TOM TOP OF MASONRY THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH TYP VIF TYPICAL VERIFY IN FIELD CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO UON UNLESS OTHERWISE NOTED THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. WWF WELDED WIRE FABRIC W/ WITH 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED 'OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-AIOBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. clearw're° 5608 LAKE WASwNGTON BLVD NE SUITE 130O KIRKLAND. WA 98033 MAX ENGINEERING, LLC WW SW FREEWAY, Ste - 410 Houston, Texas 77074 Phone (713) 773-2625 Fax (713) 773-2568 EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON OR SUITE /103 FOLSOM, CA 95630 G--1 GENERAL NOTES REVISION 0 to I— r--I 0 I n w~ O j \ `/ I o ci Q' N rn a U 3 o 0_ w 5 U G--1 GENERAL NOTES REVISION 0 to 0 n n 0 z O U z O 0 0 W c N N 0 G--1 GENERAL NOTES REVISION 0 M*4 ZONE: AR -AG. RES. I I ZONE: AR -AG. RES. ZONE: AR -AG. RES. I I ZONE: R4 BUTTE COUNTY I I BUTTE COUNTY i BUTTE COUNTY I (RESIDENTIAL TOWNHOUSES I I ` BUTTE COUNTY I I Y ZONE: AR ZONING — — — — — — — _ — — — — — _ I LLJ ' ZONE: AR—AGRICULTURAL RESIDENTIAL - - BUTTE COUNTY I I ` � ZONE: R4 I I I I RESIDENTIAL TOWNHOUSES I Q I ZONE: AR -AG. RES. ZONE: AR -AG. RES • ZONE: AR -AG. RES. I BUTTE COUNTY BUTTE, COUNTY BUTTE COUNTY I BUTTE COUNTY QI ' ZONE: AR—AG. RES. ONE: AR—AG. RES. ZONE: AR—AG. RES. NE: R4 ROSIDENTIAL TOWNHOUSES — — — — — BUTTE COUNTY — [BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY IPROPERTY LINE 656'-i7' i I ZEXIST LEGAL DESCPRIPTION: LANDSCAPING +I ., ALL THAT CERTAIN REAL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, (n I i.l CITY OF CHICO, DESCRIBED AS FOLLOWS: W UJI z I X ARCEL ID: 1A OT 7 K 7 2, L 9 ,BLOC 0 I I ADJACENT ZONING I ZONE: S -R-1/2 SUBURBAN RESIDENTIAL EXISTING W +i MASONIC 0 I BUTTE COUNTY a EXISlI= 130`(*) T- TEMPLE cx 0' c IIAOBILE LATTICE TOWERNIN I a SITE ENTRY ZO aIWC/POSED j ZONE: A-5 AGRICULTURAL IRE ANTENNAS BUTTE COUNTY i A I ADJACENT ZONING ZONE: S -R-1/2 SUBURBAN RESIDENTIAL bI BUTTE COUNTY EXIST ��- -- . ZPARKING I EXISTING LOT 7 I I o I GARAGE I 1 10 1 IN PROPERTY LINE 666' (+/-) ' Wit ADJACENT ZONING I ZONE: A-5 AGRICULTURAL 57'-7' 601'-T± I 1 BUTTE COUNTY \ LEASE AREA \ \ EXISTING \ I LANDSCAPING ADJACENT ZONING \ I ' ZONE: A-5 AGRICULTURAL \ BUTTE COUNTY 4 \ NORD AVE. -- -- -- -- -- -- SITE PLAN -- -- -- -- -- --�/ \� 1 \ \ ® SCALE: 1" = 50'-0" (24x36 SIZE) SCALE: 1" =100'-0" (11x17 SIZE) clearw're° 5808 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 5000 SW FREEWAY, Ste • 410 Houston Texas 77074 Phone 0191.779-2626 Fax 17187 773-2666 .to••'1 EPIC WIRELESS aRDLIP. INC. 381 S. LEXINGTON DR. SUITE /103 FOLSOM. CA 95630 A- I SITE PIAN REVISION 0 0 C) n O / `J C3 o10 4 N OX Irk E7' n , U o 0 V A- I SITE PIAN REVISION 0 0 n r. 0 z 0 U tr V) V) O 0 0 W � In V1 N 0 A- I SITE PIAN REVISION 0 EXISTING 4' WIDE MAN + y - GATE. x— x— x— x— xJ • EXISTING COAX SHROUD •> n n ZEXIST. CONC. of I SLAB 41 W I D 1 EXISTING GARAGE cm 0 Z I Y Ln X W x O e x'_ N, x x ENLARGED SITE PLAN SCALE: 1/4" = 1'-0" (24x36 1' SIZE) I 1 I WEST ELEVATION SCALE: 1/8" = -0" (11x17 SIZE EXISTING EQUIPMENT EXISTING OMNI ANTENNAS EXISTING MW DISH ANTENNA EXISTING PANEL nj319g ANTENNAS -j , P-ROPOSED. CLEARWIRE .(4) • ` SECTOR ANTENNA ARRAY W/1 A-4 FURE, TURC O 113 _' (t) ..ea.�.�0€AlfPROPOSED"(4)- t.6 ��pjj•g^q MICROWAVE ANTENWIS O A-4 S3DAmA1,l DYIAVA119 EXISTING 130'(±) T -MOBILE LATTICE TOWER (DESIGNED BY OTHERS) EXISTING FIR TREE EXISTING GARAGE (BEYOND SITE) — PROPOSED CLF.ARWIRE CABINET ON EXISTING A-3 CONCRETE SLAB — NEW GPS ANTENNA MOUNTED 3 ON EXISTING CONCRETE SLAB E-1 — EXISTING 6' HIGH CHAIN— LINK FENCE WITH (3) STRAND BARBED WIRE — EXISTING UTILITY H—FRAME '�'— EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) 2 SCALE: 1/16" = 1'-0" (11x17 SIZE) clearw0re® 5805 LAKE WASHWOTON BLVD NE SUITE /300 KIRKLAND• WA 98033 MAX ENGINEERING, LLC 8000 SW FREEWAY, Ste • 4110 Houston. Texas 77074 Phone (713) 773-2525 Fax 17191 T73-2568 f�'_ EPIC WIRELESS GROUP, INC. 381 S. LF7mtGTON OR. SURE /103 FOLSOM. G 955,70 W W EXISTING 6' HIGH CHAIN— AND ELEVATION REVISION LINK FENCE W/3 STRANDS OF BARBED WIRE. EXISTING UTILITY EXISTING 130'(±) T—MOBILE H—FRAME LATTICE TOWER W/ 1 PROPOSEDCLEARWIRE n (4) SECTOR ANTENNA A-4 EXISTING EQUIPMENT O 1 `/ z i ARRAY & (4) MICROWAVE CABINETS (BY OTHERS) ANTENNA. $EE NOTE BELOW PROPOSED CLEARWIRE CON(2 CABLE CONDUIT W/ SHROUT 0 RUN ON CONIC. SLAB. E - PROPOSED CLEARMIRE z CABINET ON EXISTING ej CONCRETE SLAB A-3 13'-0" 3-0" 7'-C' 11'-0" 0 CLEARWIRE LEASE AREA 34'-0" ± EXISTING FENCED AREA NOTE: U LOCATE MW ANTENNAS 1' MW DISH AZI O 16' 2' MW DISH AZI ® 89' 1' MW DISH AZI O 131' 2' MW DISH AZI O 269. SEE DTL 6/A-4 FOR ANTENNA ORIENTATION ENLARGED SITE PLAN SCALE: 1/4" = 1'-0" (24x36 1' SIZE) I 1 I WEST ELEVATION SCALE: 1/8" = -0" (11x17 SIZE EXISTING EQUIPMENT EXISTING OMNI ANTENNAS EXISTING MW DISH ANTENNA EXISTING PANEL nj319g ANTENNAS -j , P-ROPOSED. CLEARWIRE .(4) • ` SECTOR ANTENNA ARRAY W/1 A-4 FURE, TURC O 113 _' (t) ..ea.�.�0€AlfPROPOSED"(4)- t.6 ��pjj•g^q MICROWAVE ANTENWIS O A-4 S3DAmA1,l DYIAVA119 EXISTING 130'(±) T -MOBILE LATTICE TOWER (DESIGNED BY OTHERS) EXISTING FIR TREE EXISTING GARAGE (BEYOND SITE) — PROPOSED CLF.ARWIRE CABINET ON EXISTING A-3 CONCRETE SLAB — NEW GPS ANTENNA MOUNTED 3 ON EXISTING CONCRETE SLAB E-1 — EXISTING 6' HIGH CHAIN— LINK FENCE WITH (3) STRAND BARBED WIRE — EXISTING UTILITY H—FRAME '�'— EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) 2 SCALE: 1/16" = 1'-0" (11x17 SIZE) clearw0re® 5805 LAKE WASHWOTON BLVD NE SUITE /300 KIRKLAND• WA 98033 MAX ENGINEERING, LLC 8000 SW FREEWAY, Ste • 4110 Houston. Texas 77074 Phone (713) 773-2525 Fax 17191 T73-2568 f�'_ EPIC WIRELESS GROUP, INC. 381 S. LF7mtGTON OR. SURE /103 FOLSOM. G 955,70 W W ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 C� n Co O 1 `/ z i o (D O N OI NL) n� a U 3 o c; A* -2 W ENLARGED SITE PLAN AND ELEVATION REVISION 0 0 n 0 z 0 U I �rn z 0 O 0 LL3 w � o N N 0 A* -2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 r APPROVED Deve` 1__ 1���lopment Plan DATE 1 l.0 .- � -;111r,I VARIANCE s U. P. . ADM.PERMIT,._.,.. PLANNING COMMISS. PLANNING MANAGER I 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 1 1 i UEBI C O N S U L T I N G National Environmental Management and Engineering Services EBI Consulting Four A Street Burlington, MA 01803 Phone: 781.273.2500 Toll Free: 800.786.2346 Fax: 781.273.331 1 C011tltii'rY . AUG 14 2006 DEVE LOMWENT SER ACEs RADIOFREQUENCY EMISSIONS COMPLIANCE REPORT . r-Im CA-CHC01 I EASTA VENT-MOB/LE CH/CO, CA EBI PROJECT 61063526 August 10, 2006 Prepared for: CLEARWIRE CORPORATION EBI CONSULTING FOUR A STREET BURLINGTON, MAO 1803 800-786-2346 PROJECT #61063526 RADIOFREQUENCY EMISSIONS COMPLIANCE REPORT CA-CHCOII EA S TA VEIT- MOBIL E CH/CO, CA August 10, 2006 Prepared for.- Clearwire Corporation and Epic Wireless Group t UEBI Four A Street Burlington, MA 01803 Tel: 781273.2500 Cc�NSUL`t'I(YG www.ebiconsulting,com Fax: 781.273.3311 s August 10, 2006 Mr. Bryon Sattler ClearWire Corporation c/o Epic Wireless Group ' 381 S. Lexington Drive, Suite 103 Folsom, CA 95630 Subject Radiofrequency Emissions Compliance Report EastAve/T-Mobile, Chico (CA-CHC011) ' 1110 W. East Road, Chico California 95926 EBI Project #61063526 Dear Mr. Sattler: Attached please find our RAD/OFREQUENCYEM/SS/ONSCOMPLIANCE REPORT, (the Report) for the proposed telecommunications installation at the address noted above (the Subject Property). The purpose of this Report is to evaluate the above -referenced property for radiofrequency emissions compliance requirements as specified by the Federal Communications Commission (FCC) and Butte County Zoning Code 24-262 and general industry standards. tThe Report was completed according to the terms and conditions authorized by you. There are no intended or unintended third party beneficiaries to this Report, unless specifically named. EBI is an independent contractor, not an employee of either the property owner or the project proponent, and its compensation was not based on the findings or recommendations made in the Report or on the closing of any business transaction. t n Thank you for. the opportunity to prepare this Report; and assist you with this project. Please call us if you have any questions or if we may be of further assistance. Respectfully Submitted, Mr. Richard Beauregard RF-EME Plan Preparer (617) 715-1823 Mr. Kevin McManus RF-EME Program Director (617) 715-1835 L6--7-2�� Ms. Julia Jongsma Program Manager (206) 774-8473 Radiofrequency Emissions Compliance Report C4-CHC011 /0 W. East Road, Chico, CA TABLE OF CONTENTS Page iI. INTRODUCTION 2 II. PROJECT DESCRIPTION 3 III. SITE DESCRIPTION 4 IV. FCC RADIOFREQUENCY EMISSIONS REQUIREMENTS 4 ' V. EMISSIONS COMPLIANCE EVALUATION FOR CLEARWIRE AND OTHER CO-LOCATED CARRIERS 5 VI. EMISSIONS FROM OTHER SOURCES (LOCATED WITHIN 2,000 FEET OF PROJECT SITE) 7 VII. SUMMARY AND CONCLUSIONS 8 VIII. LIMITATIONS 9 IX REFERENCES c 10 APPENDIX A: Site for Proposed Questionnaire Clearwire Corporation Telecommunications Equipment APPENDIX B: Site Plans APPENDIX C: Other RF Emissions Sources in Vicinity of Project Site APPENDIX D: RoofView® Export Files 1 Radiofrequency Emissions Compliance Report G4-CHC0/ / ///0 W. East Road, Chico, CA I. INTRODUCTION ' EBI CONSULTING (EBI) has prepared this Radiofrequency Emissions Compliance Report Radiofrequency Emissions Compliance Report on behalf of Clearwire, Inc. for the proposed installation of telecommunications equipment at an existing lattice tower located on I 110 East Avenue, Chico, California. The Butte County Zoning Code 24-262 requires the preparation of a report by a qualified radiofrequency engineer stating the maximum radiofrequency radiation to be emitted by the project, and an evaluation of compliance with Federal Communications Commission (FCC) safety standards. The conclusions provided by EBI are based solely on the information obtained by file review at the Butte County planning office, information obtained from the agencies noted in the Report, and information provided by the Client. It is our understanding that this Report is to be used and distributed exclusively for purposes connected with the permitting for telecommunications site construction and operation. This Report may be relied upon by others, as authorized by EBI in writing, subject to the limitations set forth in this document and other referenced documents. t IEBI Consulting 2 t 1 Radiofrequency Emissions Compliance Report CA-CHCO/ / / / /0 W. East Road, Chico, CA II. PROJECT DESCRIPTION ' This project involves the addition of three (4) panel antennas and four (5) microwave dish antennas and associated equipment by Clearwire Corporation to an existing cellular communications tower facility located at I 110 East Avenue in Chico, California. Butte County Zoning Code 24-262 requires a report by a qualified radiofrequency engineer stating the maximum radiofrequency radiation to be emitted by the facility and demonstrating that the proposed equipment will confirm to FCC safety standards (as stated in FCC OET Technical Bulletin 65 (1997) titled, "Evaluating Compliance with FCC Guidelines for Human Exposure to IRadiofrequency Electromagnetic field. '). For this analysis, EBI Consulting has utilized several sources of information regarding the existing ' and proposed telecommunications equipment for the facility. This includes a consultation and a file review with the Butte County Planning Department, review of previous RF-EME compliance I reports submitted for the site, theoretical worst-case modeling for both the panel antennas and microwave dish antennas, and assessment of other license holders within 2,000 feet of the facility. t [l EBI Consulting 3 t n IJ Radiofrequency Emissions Compliance Report CA-CHCOI / ///0 W. East Road, Chico, CA III. SITE DESCRIPTION ' The proposed equipment will be installed at an existing lattice tower site located at I 110 East P Pg Avenue in Chico, California. An existing 130 -foot tall lattice tower and associated telecommunications equipment shelters and utilities are located behind (to the north) the Masonic Temple at the western side of the property. The tower is owned by T -Mobile, and T - t s Mobile is currently operating panel and microwave antennas at the site. The existing panel and microwave antennas are located at an approximate height of 120 and 125 feet respectively, above ground level. ClearWire Corporation is proposing to mount four panel antennas at a centerline height of 106 feet above grade and four microwave dishes at a centerline height of 110 feet above grade. The locations and configuration of equipment proposed by ClearWire Corporation, as well as existing site equipment, are shown in Appendix B (Site Plans). IV. FCC RADIOFREQUENCY EMISSIONS REQUIREMENTS Radiofrequency energy, a form of non -ionizing electromagnetic energy (RF EME), is emitted from telecommunications antennas. Under certain conditions, human exposure to radiofrequency energy can cause partial body heating. The Federal Communications Commission (FCC) has developed maximum permissible exposure limits (MPE) that help identify risks associated with human exposure to radiofrequency energy. First, the occupational, or controlled MPE,'applies to individuals who may come into contact with radiofrequency energy as a consequence of their employment, but have been made fully aware of the potential for exposure and have the ability to exercise control over the exposure. Second, the uncontrolled, or general population MPE, applies to the exposure the general public may experience, and they are generally unaware of the potential for exposure. The FCC's MPEs are measured in terms of the power that emits through the antenna, (power density) extending over a surface area. These MPEs vary with the frequency of the emitted RF energy, as shown below in Figure 1. Cellular/PCS frequencies typically range from 800 megahertz (MHz) to 2.5 gigahertz (GHz). Microwave frequencies typically utilize higher frequencies, ranging up to 50 GHz. For the equipment evaluated within this analysis, the FCC's most stringent limit for uncontrolled/general population is I mw/cm2 (based upon the T -Mobile equipment that is assumed to be operating at a frequency of 1900 MHz). As the focus of this report is on the potential impacts to the general public outside the controlled areas of the facility, EBI has evaluated compliance relative to the FCC's uncontrolled MPE limit. EBI Consulting 4 Radiofrequency Emissions Compliance Report CA-CHC01 / ///0 W. East Road, Chico, CA a Figure r. FCC Lhwi:s ;or )Maximum PennissrLle Fxioosure (?,IPES P iave-,vave Equiva and PQ4uer DensrPy, j I 1 ?L 0_0j 3ener:? Fo���.;c':�'iir;cc:atroi;ec'.�x�+psu:s Frequency (r-:1Hz) Source: Federal Communications Commission, Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields, OET Bulletin 65, Edition 97-01, August 1997, p. 68 The FCC has established several different methods for determining the power density emitted from an antenna. For the purposes of this safety plan, EBI has utilized theoretical models to estimate power density. The FCC recognizes that these theoretical models over-estimate the actual exposure one would experience and generally considers the results to represent a worst- case exposure scenario. The actual power density is expected to be much less because the antennas do not operate continuously at full power. V. EMISSIONS COMPLIANCE EVALUATION FOR CLEARWIRE CORPORATION AND CO -LOCATED CARRIERS To assess the cumulative RF impacts of the proposed ClearWire equipment and other co -located carriers from the site, EBI has compiled available antenna operational specifications from previous report submittals and run a RoofView® analysis to predict worst-case RF emissions fields at the nearest property boundary. RoofView® is a widely -used predictive modeling package that has been developed by Richard Tell Associates to predict both near field and far field RF power density values for roof -top and tower telecommunications sites produced by vertical collinear 1 antennas that are typically used in the cellular, PCS, paging and other communications services. The model utilizes several operational specifications for different types of antennas to produce a EBI Consulting 5 t t t t t t Radiofrequency Emissions Compliance Report CA-CHCOI / l / l0 W. East Road, Chico, CA plot of spatially -averaged power densities that can be expressed as a percentage of the applicable exposure limit. For this report, EBI utilized the FCC's general exposure limits outlined in OET Bulletin 65. NOTE EN retained Richard Tell Associates to provide technical support services in modeling and evaluating compliance with FCC and municipal requirements. To augment this analysis, EBI has also conducted a separate evaluation the RF emissions fields resulting from the microwave dishes. These antennas must be evaluated separately because RoofView® is designed to address impacts from vertical collinear, and cannot be used for microwave dish configurations. The table below outlines the specifications for the proposed ClearWire equipment and other carriers' equipment utilized for the RoofView® analysis. Where information is incomplete or inconsistent with previous reports filed for the site, EBI has utilized worst-case conservative assumptions to maximize the predicted RF fields resulting from the model runs as indicated by a table footnote. Carrier Frequency Radiated # of Transmitters Beamwidth/ Antenna'Centerline (MHz) Power per Sector . Aperture Height (AGL) (Watts) (degrees/feet) (feet) ClearWire 2500- 50 I 90/3 108 Corporation 2686 T -Mobile 1900 1001 I 65/61 119 (approx.) T -Mobile 1900 1001 I Omni/101 135 (approx.) I Conservative assumption based upon technical knowledge In addition to the information presented above, the following conservative assumptions were used for RoofView® modeling: • All antennas on the tower were placed at the same location (given the same X,Y coordinates); • For existing carriers with multiple antennas per sector, it was assumed that all of the power for the sector would transmit from one antenna; • The antennas for the existing carriers are oriented in the same directions as the ClearWire Corporation antennas. EBI Consulting 6 [i 1 n Radiofrequency Emissions Compliance Report CA-CHCO/ / / l /0 W. East Road, Chico, CA RESULTS The RoofViewO Modeling results indicate that the worst-case emitted power density from the combined impacts from Clearwire's proposed equipment, together with that of existing carriers on the site, will not exceed the FCC's general exposure limits at ground level in any uncontrolled areas. At ground level, worst-case power densities at the closest property boundary are estimated at 0.0021 mW/cm', or 0.211 % of the FCC's uncontrolled limits. (MPE= I mW/cm' derived from the FCC calculation utilizing the lowest estimated frequency onsite of 1900MHz) The RF fields associated with the microwave antennas were calculated separately (see Appendix D). The power density from the microwave antennas were conservatively estimated using a methodology developed by Richard Tell Associates and presented in "Summary of Near Field Power Density Calculations for EB/ Consulting'. At ground level, worst-case power densities from the microwave antennas are estimated to be 0.0016 mW/cm', or 0.164% of the FCC's uncontrolled limits. Please note that this is a conservative estimate of power density as the equations for near field exposures were used in the calculations. It is likely that any public exposure would be beyond this near field region. Generally, beyond the near field region of microwave dish antennas, power density decreases inversely with distance, or inversely with the square of distance, depending upon the distance(s) under evaluation. As such, the power density beyond the near field region would likely be significantly less than the predicted value. VI. EMISSIONS FROM OTHER SOURCES (WITHIN 2,000 FEET OF PROJECT SITE) EBI has conducted a review of the FCC's database to determine the location of licensed telecommunications facilities within 2,000 feet of the project site. Our review indicates that there is one licensed facility in the vicinity, but it is located beyond 2,000 feet from the project site (See Appendix C). It should be noted that the FCC database is likely to be incomplete for many telecommunications sites, due to (a) the regional nature of cellular/PCS license authorizations, which can generate antenna/equipment installations that are not reported for this database; and (b) the FCC reporting thresholds which exempt many categories of facilities. However, the associated RF emissions fields associated with these unlisted sources would be attenuated very rapidly with increasing distances, and the height above ground for these structures. As a result, cumulative ground -level impacts from these sources, operating concurrently with the equipment at the Estes Drive site, are expected to be well below the FCC's general exposure guidelines. EBI Consulting 7 I [I 1 Radiofrequency Emissions Compliance Report CA-CHC01 / l l l0 W. East Road, Chico, CA VII. SUMMARY AND CONCLUSIONS In accordance with the Butte County Zoning Code 24-262, EBI has prepared a Radiofrequency Emissions Compliance Report for the proposed telecommunications equipment to be installed by Clearwire Corporation on an existing self-support lattice tower located at I 110 East Avenue in Chico, California. EBI has performed a review of existing and proposed equipment and conducted theoretical modeling to estimate the worst-case power density from each antenna. Our findings regarding the Subject Site are as follows: I. The worst-case emitted power density from the combined impacts from Clearwire's proposed equipment, operating concurrently with that of existing carriers on the site, will not exceed the FCC's general exposure limits at ground level in any uncontrolled areas. At ground level, worst-case power densities at the closest property boundary are estimated at 0.0037 mW/cm2, or 0.375% of the FCC's uncontrolled limits. Members of the general public will continue to be restricted from areas where potential exceedances can be found (on the tower, directly in front of antenna faces), by site control and access restrictions. 2. The only potential exceedances of FCC's limits are for occupational exposures to telecommunications workers conducting work on the monopole. The power densities will also not exceed FCC occupational exposure limits in the center of the tower but may exceed the FCC's occupational limit directly in front of the antenna faces. Workers involved in tower operation and maintenance activities are typically provided detailed RF - safety training; they follow detailed standard operating procedures (SOPS), including the use of personal RF monitors, antenna lockout-tagout protocols, and limits on the time of exposures in front of active antennas, to ensure compliance with the FCC's occupational exposure limits. 3. There are no significant cumulative, ground -level impacts from other known RF emissions sources located within 2,000 feet of the facility, due to the rapid attenuation of RF power density fields associated with the proposed and existing equipment, and the distances of the nearest FCC licensed facilities. EBI Consulting 8 t Radiofrequency Emissions Compliance Report C4-CHCOI l ///0 W. East Road, Chico, CA VIII. LIMITATIONS This Report was prepared for the use of ClearWire Corporation. It was performed in accordance with generally accepted practices of other consultants undertaking similar studies at the same time and in the same locale under like circumstances. The conclusions provided by EBI are based solely on the information obtained by visual inspection of the Subject Property, information obtained from the agencies noted in the Report, and information provided by the client. The observations in this Report are valid on the date of the investigation. Any additional information that becomes available concerning the Subject Property should be provided to EBI so that our conclusions may be revised and modified, if necessary. This Report has been prepared in accordance with Standard Conditions For Engagement and authorized proposal, both of which are integral parts of this Report. No other warranty, expressed or implied, is made. L C� fl 1 1 t EBI Consulting 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Radiofrequency Emissions Compliance Report IX. REFERENCES CA-CHCOI l l l /0 W. East Road, Chico, CA Federal Communications Commission, Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields OET Bulletin 65, Edition 97-0/, August 1997, p. 68 Richard Tell and Associates. Summary of Nearreld Power Density Calculations for EBI Consulting. July 21, 2006 EBI Consulting 10 i Radiofrequency Emissions Compliance Report CA-CHCOI / IEast Avenue/T-Mobile, Chico, CA i t L s 1, U, 1 t APPENDIX A Site Questionnaire for Proposed Clearwire Telecommunications Equipment EBI Consulting Radiofrequency Emissions Compliance Report C4-CHC011 East Avenue/T-Mobile, Chico, CA RF-EME Site Compliance Questionnaire CA-CHC01 I—I 110 East Avenue/T-Mobile, Chico CA EBI Consulting 12 Site Data I. Antenna Latitude (or UTM 39-44-45.5 coordinate) 2. Antenna Longitude (or UTM 121-52-56.1 coordinate) 3. Location (City, State, Zip) Chico, CA 95926 4. Maximum Design RF EME Output per 50W Sector (Watts or dBM) 5. Frequency (MHz) 2500-2686 mHz 6. Antenna Gain (dB) 17 db, 7. Total Line Loss from all components ? (assume 1.5) 8. Type of Antenna Feed line and size 7/8" LDF (diameter) of coaxial cable 9. Type of Antenna 4- Stella Doradus #26SD9890 Microwave Orthogon OS Gemini Lite 5.8 GHz Orthogon OS Gemini Lite 5.8 GHz Dragonwave 24 GHz Dragon ave 24 GHz 10. # of Transmitters per Sector 11. # of operating antennas to be 4 panel antennas & 4 MW dishes modeled 12. Other Carriers/Equipment on Site? 1. T -Mobile (specify if known) 13. Antenna Height above Ground or 4 panel antennas @ 110' & 4 MW Roof Level? dishes 106'. (specify height from ground or roof to base of antenna) EBI Consulting 12 Radiofrequency Emissions Compliance Report CA-CHCOI l East Avenue/T-Mobile, Chico, CA APPENDIX B SITE PLANS EBI Consulting 13 EAST AVE. / T -MOBILE cn-a+con PROSECT DESCRIPTION CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (9) ANTENNAS (FOUR (4) PANEL & FIVE (5) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. VICINITY MAP t SITE Z:\Cleorwire\Drawings\PTS\2005\05255 (CA-CHCO11 East Ave - T- Mobile)\Dwgs\CD\CA-CHC011 MAP.bmp • SITE INFORMATION PROJECT CONTACTS SITE ADDRESS: 1110 W. EAST ROAD GENERAL CONTACT: LONNIE GUIN CHICO, CA. 95926 CLEARWIRE 5508 LAKE WASHINGTON BLVD. KIRKLAND. WA 98033 (425) 216-7821 PARCEL NUMBER: 042-070-197 FAX (425) 216-7900 SITE DESIGN: STEVE ISHIHARA LATITUDE: 39' 44' 45.5' N PACIFIC TELECOM SERVICES (206) 464-4412 LONGITUDE: 121' 52' 56.1' 8 FAX (206) 903-8513 SISHIHARAOPTSWA.COM DRIVING DIRECTIONS LAT/LONG TYPE: NAD 83 SITE CONTACT: DAN DUTTON —FROM REDDING. MERGE ONTO 1-5 (SOUTH) ELEVATION: 167' LEGACY WIRELESS SERVICES —TAKE THE CA-99/CA-36EX1T TOWARD CHICO/ (503) 656-5300 LASSEN PARK. CURRENT USE: TEMPLE MASONIC/ FAX (503) 656-5305 TELECOMMUNICATIONS DDUTTON® —TURN SLIGHT RIGHT ONTO CA-36/CA-99 CONTINUE FACILITY LEGACY—WIRELESS.COM TO FOLLOW CA -99 S. PROPOSED USE: TELECOMMUNICATIONS FACILITY PROPERTY OWNER: CHICO—LELAND STANDFORD MASONIC TEMPLE —TAKE EAST AVE. RAMP. POWER: PG & E ASSOCIATION P.O. BOX 784 —TURN RIGHT ONTO EAST AVE. TELCO: SBC PACIFIC BELL CHICO. CA. 95927 530-342-7143 —ARRIVE AT 1110 W. EAST AVE. JURISDICTION: BUTTE COUNTY ZONING: A-5 AGRICULTURE SITE OWNER: T—MOBILE DIANE TARDIFF APPLICABLE CODE: 2001 CALIFORNIA BUILDING 425-398-7550 STANDARDS CODE - - - CONSTRUCTION TYPE: V—N OCCUPANCY TYPE: UNOCCUIPED PROJECT AREA: 49 SQ. FT. PR.OJECT TEAM clearw're° -- PACIFIC TELECOM LEGACY wireless services 5508 LAKE WASHINGTON BLVD, 568 FIRST AVE S, SUITE 650' 4252 SE INTERNATIONAL SUITE 300 SEATTLE, WA 98104-2804 SUITE F KIRKLAND, WA 98033 MILWAUKIE, OR 97222 DRAWING INDEX SHEET CON TEN TS T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ` ENLARGED SITE PLAN AND ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS A-5 ANTENNA DETAILS E-1 GROUNDING PLAN AND DETAILS clearWre° PACIFIC TELECOM GAZLEY PLOWMAN 2701 NW Vaughn ARCHITECTS Suite 764 lord cL Or. 97210 503 274 7800 T-1 nilE SHEET AND GENERAL INFORMATION REVISION i 0 U 3 L2 a 3 co3 3 M N I M O al 'a O N X Q 4 0 0 0 m N d M 0 O .Ni Z O 2 a d O m m 3 W H Q O N IO V1 w Q H (A GJ to V) w U w w Ini 0 U w U LL U 4 rr��GZLEY "'1" -Mobile PLOWMAN ARCHITECTS 19807 N. CREEK PARKWAY N. 2701 NW VAUGHN, SUITE 764 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS BOTHELL, WA 98011 PORTLAND, OR 97210 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. clearWre° PACIFIC TELECOM GAZLEY PLOWMAN 2701 NW Vaughn ARCHITECTS Suite 764 lord cL Or. 97210 503 274 7800 T-1 nilE SHEET AND GENERAL INFORMATION REVISION i 0 U 3 L2 a 3 co3 3 M N I M O al 'a O N X Q 4 0 0 0 m N d M 0 O .Ni Z O 2 a d O m m 3 W H Q O N IO V1 w Q H (A GJ to V) w U w w Ini 0 U w U LL U 4 11 1 1 I t r t 1 GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCUM. WRITTEN DIMENSIONS TAKE MCM04M THIS SET OF DOCUMENTS 6 INTENDED TO BE USED FOR CIAC A MMATIC PHIMOSES ONLY. UNLESS NOTED OTHERWISE TIE GEN RK CONTRACTOR'S SCOPE OF WON SHALL INCLUDE FURNISHING ALL MATERIALS. EQUIPMENT. LABOR. AND ANY REWIEMENTS DEOMID NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED N THE ORAWECS ANO OVWHER'S PROJECT MANUAL 2. THE PROPOSED FACILITY WILL BE UNMANNED NO DOES NOT REQUIRE POTABLE WATER OR SEVIER SERVICE. 3, THE PROPOSED FACILITY 6 UNMANNED AND 6 NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS 5 REQUIRED), A. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS NO DRAWINGS PROVIDED BY THE SITE OWNER DRAWINGS WERE PREPARED FROM SITE SPEOFIC DETAILS AND STANDARDIZED DETAILS DENMOPEO BY PACIFIC TELECOM SERVICES. LLL STANDARDIZED DETAILS ARE M BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTORR, THE CONTRACTOR SHALL FIELD VERIFY ALL O ENSIGNS MCDIFWATDI6 DUE TO FIELD ONO110N5 MUST BE SUBMITTED 70. AND APPROVED BY. OEAIMIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE & CONSTRUCTION OPERATION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTADDC ALL PERMITS AND I.SWIOHS & REQUIRED FOR CONSTRUCTION. CONTRACTOR SHALL RFHOW ALL TRASH AND DEBRIS FROM THE STE ON A DALY BASIS 7. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMIUARQE THEMSELVES WITH ALL OONDMONS AFFECTING THE PROPOSED PROJECT. IL CONTRACTORS 94 LL 'AST THE CONSTRUCTION STE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL eE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY ERRORS. OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARONECT/ENGIEER YOBALLY AND N NOTING THE GENERAL CONTRACTOR SMALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STMTNG WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE I' CONSTRUCTION DRAVINGS/COMTRACT DOONENTS THE CONTRACTOR SMALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL lO' CONSTRUCTION MEAMS. METHODS TECHNIQUES, SEOU04CM AID PROCEDURES FOR COO DNATUC ALL PORTIONS OF THE WORK UNDER THE CONTRACT. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MAMUFACTURER5D /VEOYW S SPECIFICATIONS UNLESS NOTED OTHERWISE OR ERE LOCAL Il. CODES OR ORDINANCES TAKE PRECEDENCE ALL VIM PERFORMED ON THE PROJECT AMD MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APC1BUL LJHE CODER. REGULATIONS. AND ORDNANCE& CONTRACTOR 12 SHALL ONE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUMOM. MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS. AND LOCAL AND STATE JURISDICTION& CODES BEARING ON THE PERFORMANCE OF THE WORK THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITES ARE NOT TO 13. BE ALTERED BY TOS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE SEK ALL PEETRATONS TROUGH FIRE—RATED AREAS WITH U.L LISTED OR FIRE IA. MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACEUTY AND OR PROJECT SITE CONTRACTOR IE TO PROVIDE A PORTABLE FEXTINGUISHER WITH A RATING of NOT LESS MAN 2—A OR 2—AIWC WITHIN 73 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT 13. AREA WRING CONSTRUCTION CONTRACTOR SHALL HAKE NECESSARY PROVISIONS TO PROTECT EoSTINO OFRO14NEMi& EASEMENTS. PAWING WRING ETC. WRING CONSTRUCTION UPON COMPLETION OF WORK. Is. 0 CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DIE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. THE AROOTECTS/EIFAME)LS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT OOGNENIS THE COMPLETE SCOPE OF WORK. 17. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MOON OMISSIONS OR ERRORS N THE DRAWINGS AND OR SPECIFICATIONS SMALL NOT DOWSE SAID CONTRACTOR FROM COMPLETING THE PROECT AND IMPROVEMENTS N ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SMALL BEM THE RESPONSIBILITY OF NOTIFYING (N WRITING) THE ARODTECT/EUAEED OF MY CONFLICTS, ERRO!L OR OMISSIONS PION TO SUDM690N OF CONTRACTORS PROPOSAL IN THE EVER OF DISCREPANCIES THE CONTRACTOR 94ALL PRICE THE MORE COSILY AIR EX10/9VE WORK, UNLESS DIRECTED OTHERWISE THE CONTRACTOR SMALL PERFORM VOW DURING OWNER'S PREFERRED HOURS TO AVIOID DISTIBNG NORMAL BUSINESS, ,EL CONTRACTOR SHALL CALL LINDERCROLI D SEANCE ALERT (USA) IN CALIFORNIA FOR UNDERGROUND UTILITY MARKWY PRIOR TO CONSTRUCTION. 1—IEEE-227-2600. 10. ABBREVIATIONS: ADJ ADJUSTABLE Q AND APPROX APPRODMATE O AT BTS BASE TRANSMISSION STATION CAB CABINET CLG CEILING CONC CONCRETE CONT CONTINUOUS DIA OR I DIAMETER DWG DRAWING EA EACH ELEC ELECTRICAL ETEV ELEVATION EO EQUAL EQUIP EQUIPMENT EGB EQUIPMENT GROUND BAR (E) EXISTING EXT EXTERIOR FF FDOSHEO FLOOR GA GAUGE GALv GALVANIZED GC GENERAL CONTRACTOR GRND GROUND LG LONG MAX MAXIMUM MECH MECHANICAL NFT( MANUFACTURER MOB MASTER GROUND BAR MIN MINIMUM MTL METAL NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OPP OPPOSITE PCs PERSONAL COMMUNICATION SYSTEM SF SOUARE FOOT SHT SHEET SIM SIMILAR SS STAINLESS STEEL STL STEEL TOC TOP OF CONCRETE TOM TOP OF MASONRY TYP TYPICAL VG VERIFY IN FIELD LION UNLESS OTHERWISE NOTED WWF WELDED WIRE FABRIC W/ WITH clearw're• PACIFIC TELECOM v GAZLEY PLOWMAN 7m "W va,ym ARCHITECTS LILA 76A N0WM4 G. 97210 103 274 78W L LJ CC) O f"" U \ U Ld iU L LJ GO W) N- O1 In W U 3 C � U U G-1 GENERAL NOTES REvRSMON T • n O O O rn I N d n 0 O W z O I OL O D to zk 0 Q D D 0 6 " I ZONE: AR -AG. RES. I I ZONE: AR -AG. RES. I ZONE AR -AG. RES (BUTTE COUNTY I I BUTTE COUNTY 1 BUTTE COUNTY. I I ZONE R4 . I I RESIDENTIAL TOWNHOUSES BUTTE "COUNTY ADJACENT ONIN • I ZONE: AR -AGRICULTURAL I RESIDENTIAL I ---- ------ ---- BUTTE COUNTY ZONE: R4 I \ I \ RESIDENTIAL TOWNHOUSES ZONE AR -AG. RES BUTTE COUNTY ^ ZONE: AR -AG. / BUTTE COUNTY RES. ZONE AR -AG. RES BUTTE COUNTY I BUTTE COUNTY \ I �ZONE: IZONE: R4 � ZONE: AR -AG. RES. / BUTTE COUNTY ZONE: AR -AG. RESN. BUTTE COUNTY AR -AG. RES. BUTTE COUNTY RESIDENTIAL TOWNHOUSES' - — BUTTE COUNTY ',EXISTING / / PROPERTY UINE 656'=7' FGA( DESCPRIPTION: o I 150' i- �TOBILE LATTICE EXIST L LANDSCAPING ALL THAT CERTAIN REAL PROPERTY n n (POWER W/ PROPOSED SITUATE, IN THE STATE OF CALIFORNIA, W / CITY OF CHICO, DESCRIBED z (C LEARWIRE ANTENNAS I AS FOLLOWS: :3 ix TAX PARCEL ID: ¢ Wa I MAP 42, LOT 197, BLOCK 07 a I o EXISTING u MASONIC 1j m 1 W TEMPLE Z¢ • `V 17 j ZONE: A-5 AGRICULTURAL BUTTE COUNTY W 1 �g L O I 11 I EXISTING LLi EXIST. PARKING LOT ,o GARAGE ADJACENT ZONING ZONE A-5 AGRICULTURAL BUTTE COUNTY 122'11 347 1• - 50'-0• l sc.-LE.T11• % in ,• - ,ar-0• PROPERTY LINE 656'-7' F- TN Q W I I I I ADJACENT ZONING ZONE: S -R-1/2 SUBURBAN RESIDENTIAL BUTTE COUNTY I—SITE ENTRY ADJACENT ZONING 1 ZONE: S -R-1/2 SUBURBAN RESIDENTIAL I I BUTTE COUNTY 1 I I " 1 1 1 \ 1 5B•_7' 6'-0' LEASE AREA 602•-2• \ 1 666'-3' \ \ I \ \ EXISTING \ I LANDSCAPING ADJACENT 70NING \ \ ZONE: A-5 AGRICULTURAL \ BUTTE COUNTY I I NORD AVE. SOME SITE PLAN I clearw're• J PACIFIC TELECOM v GAZLEY PLOWMAN ;7m . Va„y,,, ARCHITECTS sine 794 PorOm4 Or. 97210 503 274 7900 L.LJ cc < N O it N \ U W U LL) 3c U L.LJ A-1 SITE PLAN 9 clearw'reO PACIFIC TELECOM GAZLEY EXISTING 4 EXISTING OMNI PLOWMAN 2701 NW Vygh. ARCHITECTS MADE MAN + ANTENNAS sdl. 764 P.MWd. Or. 97210 GATE. iii 78003 �-, - x - x - x • 5503 Fm EXISTING EXISTING MW DISH ANTENNA (BY OTHERS) • EXISTING PANEL ANTENNAS (BY OTHERS) SHROUD CONC.� I U a SLAB W a x N _ PROPOSED (5) CLEARWIRE e MICROWAVE ANTENNAS O p 110•-0' 4 Sr PI. X1511 G GARA PROPOSED CLEARWIRE (4) SECTOR ANTENNA ARRAY F?O. W/1 FUTURE O 106'-0" 4 . rn X x o '�O XN I �y X W N O 2� I n x x -x x x -x J z w o � r r EXISTING 6' HIGH w 0 \ CHAIN-UNK FENCE W/ 3 = r EXISTING 150'-0' J w v W 3 STRANDS OF T -MOBILE LATTICE BARBED WIRE. or TOWER r EXISTING EXISTING 150' T -MOBILE m 12 EQUIPMENT LATTICE TOWER W/ 1 3 a PROPOSED CLEARWIRE EXISTING EQUIPMENT (3) SECTOR ANTENNA CABINETS (BY OTHERS) ARRAY (1 FUTURE) & (5) MICROWAVE ANTENNA. SEE z N NOTE BELOW w U ✓ PROPOSED CLEARWIRE c o UNDERGROUND CONDUIT e PROPOSED CLEARWIRE SITE n SUPPORT CABINET ON 3'X6' e a • PLATFORM. 3 O O � 3'-7" 6'-0' U N m m 0 0 cEXISTING FIR TREE w Zw� ^ - EXISTING GARAGE (BEYOND N c n 34'-0' EXISTING FENCED AREA SITE) > 0 s uE0 PROPOSED CLEARWIRE SITE 0 SUPPORT CABINET ON 3'X6' 3 e D w PLATFORM D N N EXISTING 6'-0' HIGH CHAIN - LINK FENCE WITH (3) - STRAND BARBED WIRE NOTE: LOCATEMV ANTENNAS O 1-16.25'• 2-112.63', EXISTING EQUIPMENT 3-126.39•, 4-130.79', CABINETS (BY OTHERS) -2 5-268.29' (FOR SIZES SEE SHEET A4 & A5) EXISTING EQUIPMENT ENLARG 7/D STE PUN AND ELEVA110N SCALE i,11' ri,'/W=,'-� �• ENLARGED SITE PLAN 2 - f,': �TI';n =�-0 �. WEST ELEVATION I SCALE •] 2 1 0 • 8 6. 2 0 C: u C STE SUPPORT CABINET ELEVATION B SITE SUPPORT CABINET ELEVATION CPS ANTENNA 4 IENT 3672LV) io D SITE SUPPORT CABINET ELEVATION aSITE SUPPORT CABINET ELEVATION EQUIPMENT ELEVATIONS SCALE (24'XW8 ]/P -t' -W SCALE: (11 -Mr), '-1/2• - 1'-0' 0 e CPS AN 4 TELCO I ELECTPANEL I (> PANEL POWER RECEPTA NOTE: A(t� FOR ANCHORING PLATFORM S 6/A4 EQUIPMENT PLAN SCALE (24-p9•k SCALE (n M7 ): r -'•-w clearw're♦ PACIFIC TELECOM CAZLEY PLOWMAN 2701 MrV-9h. ARCHITECTS Su to lea Parma Or. 97x'0 30.7 274 7909 30.7 274 7803 Fm LJJ 1 ' DIA. RGS m SITE SUPPORT o CABINET a = o O U ELECTRICAL o l W U U PANEL to i IJ m POWER RECEPTACLE O o U I m I^ u 2' DIA SCH. 40 1 n PVC POWER STEEL CONDUIT EOUIPMI I TELCO BOX PLATF01 (PPHe 2' DIA SCH. 40 PHP -3E PVC TELCO as CONDUIT IENT 3672LV) io D SITE SUPPORT CABINET ELEVATION aSITE SUPPORT CABINET ELEVATION EQUIPMENT ELEVATIONS SCALE (24'XW8 ]/P -t' -W SCALE: (11 -Mr), '-1/2• - 1'-0' 0 e CPS AN 4 TELCO I ELECTPANEL I (> PANEL POWER RECEPTA NOTE: A(t� FOR ANCHORING PLATFORM S 6/A4 EQUIPMENT PLAN SCALE (24-p9•k SCALE (n M7 ): r -'•-w clearw're♦ PACIFIC TELECOM CAZLEY PLOWMAN 2701 MrV-9h. ARCHITECTS Su to lea Parma Or. 97x'0 30.7 274 7909 30.7 274 7803 Fm m 0 U ODQ a h N I 0 0 m 00 0 N LLx Q ♦ O O O 0' I N a n 00 O N w Z O I a • 0 m m 3 W F w w VI O N t0 U Q H N LO t0 U) w U S w w i 0 U w U U Q a LJJ 1 REVISION 2 0 O U o W r \ l W U U i IJ �� L.L J m 0 U ODQ a h N I 0 0 m 00 0 N LLx Q ♦ O O O 0' I N a n 00 O N w Z O I a • 0 m m 3 W F w w VI O N t0 U Q H N LO t0 U) w U S w w i 0 U w U U Q a A-3 EOUIPM NT DETAILS 1 REVISION 2 m 0 U ODQ a h N I 0 0 m 00 0 N LLx Q ♦ O O O 0' I N a n 00 O N w Z O I a • 0 m m 3 W F w w VI O N t0 U Q H N LO t0 U) w U S w w i 0 U w U U Q a 6 1/6• 0 LENGTH: 5' (127 MM) WIDTH: 6.12' (155 MMJG) WEIGHT: 12.8 OZ (363 O DIAMETER: SEE NOTE DEPTH: 8.2' OFFSET: 12.2' WEIGHT: 27 LBS LATTI( 2" NO io NOTE: � PROVIDE (3) 2' DIA. & (2) 1' DIA. MICROWAVE ANTENNAS 2 MICROV 1-16.2 GPS SPECIFICATION MICROWAVE SPECIFICATION SECTOF SCALE (24'106': NOT TO SCALE 3 SCALE (24'06'): NOT TO SCALE SCALE: (Il'IOY): NOT TO SCALE SCALE (Il'x17-k NOT TO SCALE MICRO HARD) MANU' >�t 8 x 5- 11' c07 HARDI MANUI ANUI LENGTH: 35.8" LENGTH: 19.3' (49 CM) WIDTH: 5.5" WIDTH: 11.3" 128.5 CM) DEPTH: 4.5" DEPTH: 5.1' (13 CM) I WEIGHT: 5.5 LBS WEIGHT: }$ LBS (16 KG) � I e BTS r z�- O e ANTED ANTENNA SPECIFICATION BTS SPECIFICATION SCALE: (24'x36': NOT TO SCALE 7-J SCALE (21'06': MOT TO SCALE 4 SCALE (11'x17-): NOT TO SCALE SCALE (11-XWk NOT TO SCALE COAX ANTED PROVIDE 5/8" HILT) ETHER KWIK BOL -IIS WITH FROM PREFAB EQUIP 4' EMBEDMENT (AS TELCC BAS - REOUIRED O EACH SEE MFCR. SPECS PLATFORM LEG) SLOPE 6' THICK CONC. SLAB WITH 04 REBAR AT 12" ON WACH WAY AT MID SLAB TYP.�4, NOTE: VERIFY LOCATION OF RE -BAR EXISTING CRUSHED PRIOR TO ROCK BASE INSTALLATION (1'_ L 2'_ EXISTING NATIVE EARTH UNIT ANCHOR DETAIL SCALE (24'06'} NOT TO SCALE 6 SCALE: (iMr);NOT TO SCALE TOWER SECTION SCALE-' (24')06? 1-1/Y - 1'-d SCALE (Irma 3/4' - 1'-0' clearw're• PACIFIC TELECOM v GAZLEY PLOWMAN I mNr vw,. ARCHITECTS wt. 764 WUMIL Or. 97210 to Z 0 LJ U m O U - 0 N Q °1 T to \ (J W QU O Y U ' U L 1A-4 ANTENNA OETALS REVISION 2 2 0 U 3 a • n N O) I n 0 m L0 O cmX • 0 0 0 m I N a n 10 O Et w z O S O. a 0 01 m 3 w w • 0 in (D x n Q ' I- U) 01 .o i U) w U 5 w w 2 O U w _j a. F U w U a I 0 U 3 to H a • n N O I n 0 m N x Q W • O O O m I N d m 0 Et N w z 0 x a • d O m m Q 3 w 0 Q W InO N to In Q F- V) m 0 i clearw're• ' MICROWAVE • 130.79' e PACIFIC TELECOM GAZLEY PLOWMAN 2701 NW Vaughn ARCHITECTS ' 0 2' NOM. DIA. MOUNTING PIPE Suit. 764 .11 Portl-4 Or. 97210 503 274 7600 603 274 78W I- eMICROWAVE O 126.39' 0 I LATTICE TOWER m e MICROWAVE O 112.63' m 1 O 0 ca Wr�'' Q ; U_ V MICROWAVE MOUNTING HARDWARE BY MICROWAVE MANUFACTURER ANTENNA MOUNTING HARDWARE BY ANTENNA Q MANUFACTURER Lo BTS e o o 0 o 0 C ZW5 3 ANTENNA m n C N iE0 L LL W J ✓v,1 N COAX JUMPER FROM ANTENNA TO BTS ETHERNET CABLE FROM BTS TO TELCO BOX A5 SLOPE PIPE MOUNT TOWER SECTION ® SECTION 2 ANMWA OEUgS sutra (24-X36'): 1-1/2' - V -O' , REVISION 2 SCALE (11'X177: 3/4' - 1'-O' I 0 U 3 to H a • n N O I n 0 m N x Q W • O O O m I N d m 0 Et N w z 0 x a • d O m m Q 3 w 0 Q W InO N to In Q F- V) m 0 i NOTEc• I. SERVICE POWER TO EQUIPMENT SHALL BE 120/24OVAC. 100A. SINGLE PHASE. 2. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY BEFORE THE START OF CONSTRUCTION. POWER AND TELEPHONE CONDUIT SHALL BE PROVIDED AND INSTALLED PER UTILITY REQUIREMENTS AND UTILITY. 3. ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH THE N.E.C., UTILITY COMPANY AND LOCAL CODE REQUIREMENTS. LOSS OF POWER RELAYS (LPRs) WILL MONITOR UTILITY POWER. 4. GENERATOR 1 POWER R GENERATOR 2 POWER. LPRs SHALL BE LOCATED WITHIN NEMA 311 JUNCTION BOX. LPRs SHOULD BE FUSED TO ELIMINATE THE RISK OF A LPR FAULT/FAILURE CAUSING THE MAIN POWER FUSES TO TRIP. UTILITY -120/240V 1—PHASE. 3W (3)—B3/0 IN 2" CONDUIT METER (BY CONTRACTOR) 3—/3/0 + 1—/3 GRD IN 2' CONDUIT 100A 120/24OV. 1—PHASE. 3W OISTIBUTION PANEL WW/INTERGRATED MANUAL TRANSFER SWATCH AND A/C POWER TVSS BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS A MECHANICAL CONNECTION 3—p/O + (DOUBLE HOLE LUG) 1—#3 GRD IN ■ CAD WELD CONNECTION 2" CONDUIT 1—/4 SPECIFICATIONS ----� I = IOOA II TOWER AT ANTENNA IN LEVEL DISCONNECT L ----J IMPORTED SOIL 3—/3/0 + 1—/3 GRD IN 2' CONDUIT 100A 120/24OV. 1—PHASE. 3W OISTIBUTION PANEL WW/INTERGRATED MANUAL TRANSFER SWATCH AND A/C POWER TVSS BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS A MECHANICAL CONNECTION (DOUBLE HOLE LUG) ■ CAD WELD CONNECTION COMPACTED CONNECT PER MANUFACTURER SPECIFICATIONS BACKFILL WITH GROUND BAR MOUNTED SATISFACTORY TOWER AT ANTENNA 'TO GROUND BAR LEVEL BTS IMPORTED SOIL /6 GROUND LEAD TO PROPOSED CLEARVARE ANTENNA MOUNT (TYP.) UTILITY WARNING ANTENNA 2'0 CONDUIT WHERE EXISTING GROUND RING CEDCE OF / SLAB /2 SOLID IN FLEXIBLE NON—METALLIC CONDUIT LEAD TO 6' MIN. TYP. ONE LINE DIAGRAM EXISTING GROUND SCALE (24-X30 NOT TO SCALE RING CD N 0 V W 0 cr 0 FFINISHED GRADE OR Z PAVING. MATCH SLOPE AND THICKNESS OF Z EXISTING CONDITIONS W SCALE (24'11707: NOT TO SCALE SCALLS Ormrk NOT TO SCALE /6 GROUND LEAD TO OTHER PROPOSED CLEARWIRE ANTENNA MOUNT (TYP.) - #2 GROUND LEAD TO EXISTING GROUND RING EXISTING GROUND RING ATTACH TO TOWER GROUND 62 SOLIDE IN FLEXIBLE NON—METAWC CONDUIT LEAD TO EXISTING GROUND RING I clearw're' PACIFIC TELECOM v GAZLEY PLOWMAN 2704 mw %ughn ARCHITECTS sea 754 Poroma Or. 97210 r E-1 CROUP(DWO PUN AND DETALLS i 0 U 3 F a • n W m I n O 0 0 O 11 x Q 0 O O 04 I N d n 0 O W z 0 x D. • d O co 04 Q 3 W (J W N • O O k In 6 H N D) rn W U K W i D U W A r `UNDISTURBED SOIL n COMPACTED BACKFILL WITH __ io •' SATISFACTORY -:'L<�'.w^•�: NATIVE OR .'•t . IMPORTED SOIL UTILITY WARNING 2'0 CONDUIT WHERE TAPE APPLICABLE COORDINATE SIZE AND TYPE WITH LOCAL UTILITY 6' MIN. TYP. 6' 6' MIN. TYP. ONE LINE DIAGRAM CONDUIT TRENCH SCALE (24-X30 NOT TO SCALE 3 SCALE: (24-M-; NOT TO SCALE 2 SCALE: (11 -Mn NOT TO SCALE SCALE (11'X)n NOT TO SCALE SCALE (24'11707: NOT TO SCALE SCALLS Ormrk NOT TO SCALE /6 GROUND LEAD TO OTHER PROPOSED CLEARWIRE ANTENNA MOUNT (TYP.) - #2 GROUND LEAD TO EXISTING GROUND RING EXISTING GROUND RING ATTACH TO TOWER GROUND 62 SOLIDE IN FLEXIBLE NON—METAWC CONDUIT LEAD TO EXISTING GROUND RING I clearw're' PACIFIC TELECOM v GAZLEY PLOWMAN 2704 mw %ughn ARCHITECTS sea 754 Poroma Or. 97210 r E-1 CROUP(DWO PUN AND DETALLS i 0 U 3 F a • n W m I n O 0 0 O 11 x Q 0 O O 04 I N d n 0 O W z 0 x D. • d O co 04 Q 3 W (J W N • O O k In 6 H N D) rn W U K W i D U W A r i t t Radiofrequency Emissions Compliance Report CA-CHCOI l East Avenue/T-Mobile, Chico, CA APPENDIX C Other RF Emissions Sources (from FCC database) in Vicinity of Project Site EBI Consulting 14 11 C|eamvireCorporoton 5508 Lake Washington Bou|evurd, Suite 300 Kirkland, WA 98033 CA'[HCU||-East Avenue/T'Mobi|e ||0\x/ East Road Chico, CA 95926 Vicinity Location A-71 EBI 11 11' f IN C. I I i I Radiofrequency Emissions Compliance Report CA-CHCOI l IEast AvenuelT-Mobile, Chico, CA 1 r t t 11, n t EBI Consulting APPENDIX D ROOFVIEW® CALCULATIONs/EXPORT FILES 15 MMMMMM no WOM .M M M"I"M W" rM maim 0" 'S1N•�ik�t'ii(_2+;(Fa' iri:tl�+i.:;-. �: J�� Elle. Edit VleW Insert Format Tools Data Window Help Adobe PDF tyl, yur�,b!n rui Iic!U R161 C46 - 4 lic I � ❑� Use Selected Area Only Nrina Coo.Yd Fra,,i,Rmuar — iM2nf, Ht • • ��� DblClk=ONOFF I�PMUse O O Set Area Antennas Only7 AN AFF CFIt:hg 6NcarjFarSpaHalAYg Map HecalcArea talc One Pixel Last Area Hooi thresholds Calculator Statistics Snap Photo 0 '10 20 30 40 50 60 70 40 3n 20 10_ N t r 00,A 0.2109073 is % MPE at this location( 26, 30). ..... ........ ,..,, UK � Y 3 T ....................... ..... �,:�.......... ;,,........ C1.............� ....a.-.....__...y..s..s.,.. k,(___Arraur(n IddDDdld.Z.Syiii1julTdLjle .IriLruJut.Liuri t;t3't • tiJ 2 (�.'!ti„�..�x ( 1�T.a�'.�'.'��rr13.s 1 �''s� ti:.'�t�•'. Map, Settings, Antenna, and Symbol Data Table .. Exported from workbook -> RoofView 4.15.x1s Done on 8/10/2006 at 2:02:20 PM. Use this format to prepare other data sets for the RoofView workbook file. You may use as many rows in this TOP header as you wish. The critical point are the cells in COLUMN ONE that read 'Start...' (eg. Start MapDefinition) If used, these (4) headers are required to be spelled exactly, as one word (eg. StartMapDefinition) The very next row will be considered the start of that data block. The first row of the data block can be a header (as shown below), but this is optional. When building a text file for import, Add the Map info first, then the Antenna data, followed by the symbol data. All rows above the first marker line 'Start...' will be ignored, no matter how many there are. This area is for you use for documentation. End of help comments. You can place as much text here as you wish as long as you don't place it below the Start Map Definition row below the blue line. You may insert more rows using the Insert menu. Should you need additional lines to document your project, simply insert additional rows by highlighting the row number adjacent to the blue line below and then clicking on the Insert menu and selecting rows. Roof Max )Roof Max )Map Max VMap Max XY Offset X Offset Number of envelope (ft) dBd BWdth 57 71 90 90 30 10 1 $U$134:$C$U$134:$CM$190 30 Sta(— rtSettingsData 3 17 90;90 30 106 VC 3 Standard Method Uptime Scale Fad, Low Thr Low Color Mid Thr Mid Color Hi Thr Hi Color Over ColorAp Ht Mult Ap Ht Method 4 2 1 1 20 1 50 2 100 2 3 1.5 1 StartAntennaData It is advisable to provide an ID (ant 1) for all antennas 30 120 VC 6 65;270 (MHz) Trans Trans Coax Coax Other Input Calc (ft) (ft) ID Name Freq Power Count Len Type Loss Power Power Mfg Model X Y A Clearwire 2500 50 50 Stella Dora26SD9890 31 B Clearwire 2500 50 50 Stella Dora 26SD9890 31 C Clearwire 2500 50 50 Stella Dora26SD9890 31 T1 T -mobile 1900 100 100 Unkown 31 T2 T -mobile 1900 100 100 Unkown 31 T3 T -mobile 1900 100 100 Unkown 31 T Omni T -mobile 1900 100 100 Unkown 31 St(_artto (Data (ft) (ft) dBd BWdth Z Type Aper Gain Pt Dir 30 106 VC 3 17 90;90 30 106 VC 3 17 90;180 30 106 VC 3 17 90;270 30 120 VC 6 65;90 30 120 VC 6 65;180 30 120 VC 6 65;270 30 135 VC 10 omni 0 1, 11 I I I I d t 11 I I Real Estate Services Site Investigation EHS Services Atlanta, GA Baltimore, MD Burlington, MA Chicago, IL Dallas,TX Denver, CO Exeter, NH Houston,TX Los Angeles, CA New York, NY . Phoenix,AZ Portland, OR San Francisco, CA Seattle, WA York, PA Telecom Services . :r ABi! MO..+ - SS 60 ACB NQ � ADC A 7 AE Ai C O N S U L T I N G Four Street Burlington, MA 01803 Tel: 781/273.2500 Toll Free: 800/786.2346 Fax: 781/273.3311 www.ebiconsulting.com Process Engineering I 1 1 1 1 ri t VICINITY MAP ® clearWre® EAST AVE./T-MOBILE sem ,.XT .A9Rc1a aw a ENGINEERING, LLC ` \\ ' \` IMAX MOD Bw RKEWAY. 6Y . N T.a 77014 11 Q\w _IbuM CA CHCO 11 `\ j\'y; ' _ fir „(., �.,' p -M F. nM6tC 13,115113 • , PROJEC"I' DE''SCHIPTIONS 2 ,; �\ n •. r 6n \, ��' \S\ EPIC w aau\\uWD. CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (8) ANTENNAS (FOUR (4) PANEL & FOUR (4) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE \ 9`��.,Ss \� •, UIY(J+ { SITE �:�.. .Y • 6 rW.SOM, G o e]0 ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. `e•': - /' % �. SITE INFORMATION PROJECTCONTACTS32 ,( g '�::"I g 3 -bY �•` q t`ae @ aa� SITE ADDRESS: 1110EAST ROAD ARCHITECT/ SAM LAMENDOIA cW. 95 926 ENGINEERING: MAX ENGINEERING, LLC CHICCA SOUTHWEST FREEWAY 9000 Y,` _ S F •'I ' . •� \ 9 � JF,t 4 g! ATL SffE/: CA-CHC011 SUITE /410 :7, 1�_ fli�•p{ Y'�' �Cy� j_L] HOUSTON, TX 77074 PARCEL NUMBER: 042-070-197 _ Yo8RE: (717) 873-0466 g . }p'I �+�1y,�{� ,, 6L?, Pl _{gFNEA.Cg n .31�� -� M LATITUDE: 39' 44' 45.5' N GENERAL CONTACT: DAVID WRTSEE EPIC WIRELESS GROUP _ k g �\ ,.,G'' W4� ;a O LONGITUDE: 121' 52' 56.1' W { SUI SOUTH LEXINGTON DR. 5017EC 'C /-^ I FOLSOM. CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (53o) 878-9117 DRIVING DIRECTIONS DRAWING INDEX dwiltsee®sbcglobdl.nel ELEVATION: 167' AYSL - SITE OWNER: T-MOBLEL CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF TELECOMMUNICATIONS PHONE: ({25) 398-7550 FACILITY -FROM FOLSOM. CA. TAKE BARTON ROAD NORTH -TURN LEFT (WEST) ON ROCKLIN ROAD SHEET CONTENTS 7-1 TITLE SHEET AND GENERAL INFORMATION 1 O Q PROPOSED USE: TELECOMMUNICATIONS PROPERTY OWNER: LELAND STANDFORD MASONIC -TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES t— U S MM FACILITY TEMPLE ASSOCIATION P.O. BOX 784 CHICO, CA. 95927 -TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES G-1 GENERAL NOTES A-1 SITE PLAN (n I ; Q' C POWER: PG @ E PHONE: (530) 342-7143 W L) V TELCO: AT&T -TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND GO. 20 MILES. A-2 ENLARGED SITE PLAN AND SOUTH ELEVATION JURISDICTION: BUTTE COUNTY -SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX A-3 EQUIPMENT DETAILS o ZONING: A-S.AGRICULTURE 37 PILES A-4 ANTENNA DETAILS APPLICABLE CODE: 2001 CALIFORNIA BUILOING - -EXIT INTO SR 149 AND GO APPROX. 4.6 MILES O STANDARDS CODE -MERGED INTO SR99. GO APPROX. 13 MILES. E-1 GROUNDING PLAN AND DETAILS TYPE: V -N -TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO Rgz U pCOOCNSSTRUCTION PROJECT MF PE: 60 SO. FT.D - APPROX. 1.8 MILES . -SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. N O I� z In ' W C C j PROJECT "TEAM °� At on new sery ces h grounding trenches, 'WARNING' .. Provide tope at 12" below C MAX ENGINEERING, LLC ... ° aad i GALL BEFORE YOU OIG" s■MOb1Ie' clearw°re° 9000 SW FREEWAY, Ste 410 u 1 -Boo -227-2600 ALERT NORTH 1 F EPIC WIRELEBB GROUP, INC. • CALIFORNIA UNDERGROUND SERVICE 1 5508 LAKE WASHINGTON BLVD, Houston, Texas 77074 381 S. LEXINGTON DR. 19807 Nt'CREEK PARKWAY N. SUITE 300 Phone (713) 773-2525 SUITE #103 BOTHEL, WA 98011 TITLE SHEET AND INFORMATION CONTAINED W THIS SET OF DOCUMENTS 15 KIRKLAND. WA 98033 Fax (713) 773"2558THE FOLSOM, CA 95830 GENERAL INFORMATION - PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS REVISION 0 ' STRICTLY PROHIBITED. GENERAL NOTES: I. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS TAKE PRECEDENCE. THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY. UNLESS NOTED OTHERWISE THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED .NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 2. THE PROPOSED FACIUTY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 3. THE PROPOSED FACIUTY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARICRE. LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO. AND APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 5. CONTRACTOR SMALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE ,CONSTRUCTION OPERATION. S. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 8. PRIOR TO THE SUBMISSION OF BIDS. CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL NSR THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SWILL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS. TECHNIQUES, SEQUENCES. AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SMALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE 1 LOCAL CODES OR ORDINANCES TAKE PRECEDENCE, 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES. REGULATIONS. AND ORDINANCES. CONTRACTOR SMALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES. RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MU NICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. It. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPUCABLE TO THIS FACIUTY AND OR PROJECT SITE. 15. CONTRACTORTO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-AIOBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. Fr 0 0 Z O $ W o 0 G-1 GENERAL NOTES REVISION 1 0 clearw're® sem ulu WA9mtTw aw x[ ABBREVIATIONS: wm 1300- - ImKI . - cemJ AOJ ADJUSTABLE ENGINE8RING, LLC 19. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING @ AND OW 8W FREEWAY, Me, RW IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON APPRO% APPROXIMATE 111AX 11WWIUA T.-7To71 ' COMPLETION OF WORK, CONTRACTOR SWILL REPAIR ANY DAMAGE THAT MAY HAVE Y AT IWbW R49 TTa-Y6Ye OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. BTS CAB BASE TRANSMISSION STATION CABINET F. .0 TT Iuall ' C G CEILING ' 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE GONG CONT CONCRETE CONTINUOUS CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. DM ORW DIAMETER CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR DWG DRAWING ~ OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SMALL NOT EA EACH Jet s. 1ExoIcloN m. EXCUSE SOD CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ELEC ED ELECTRICAL ELEVATION sart Elm ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE EO EQUAL rinslAl, a 0!6.10 RESPONSIBILITY OF NOTIFYING (IN MARRING) THE ARCHITECT/ENGINEER OF ANY EQUIP EQUIPMENT CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S EGB EQUIPMENT GROUND BAR , PROPOSAL IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE (E) EXISTING EXTERIOR MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. EXT E FF FINISHED FLOOR ' GA GAUGE 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO GALV GALVANIZED AVOID DISTURBING NORMA_ BUSINESS. GC GRND GENERAL CONTRACTOR GROUND LMAX LONG 19. CONTRACTOR SHALL CAL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR MAXIMUM UNDERGROUND UTIUTY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2800. MECH MECHANICAL WAR MANUFACTURER .i MOB MASTER GROUND BAR W MIN MTL MINIMUM METAL ' NIC NOT IN CONTRACT • NTS OC NOT TO SCALE ON CENTER Q OPP OPPOSITE PCS PERSONAL COMMUNICATION SYSTEM - SF SQUARE FOOT SKI SHEET EI SIM SIMILAR ' SS STAINLESS STEELSTL TOC TOP OF CONCRETE >l TOM TYP TOP OF MASONRY TYPICAL e Q U m VIF VERIFY IN FIELD LION WWF UNLESS OTHERWISE NOTED WELDED WIRE FABRIC Il S W/ WITH ; Q o IiN w U �� 0 0 Z O $ W o 0 G-1 GENERAL NOTES REVISION 1 0 ' ' ADJACENT ZONING ZONE: AR -AGRICULTURAL RESIDENTIAL BUTTE COUNTY ZONE: AR -AG. RES. I I SURE COUNTY I I I - - I I SONE: AR -AG. RES. ZONE: AR -AG. RES. I I ZONE: R4 I SURE COUNTY I BUTTE COUNTY I 1 BUTTE NTUL ,TOWNHOUSES I I I BORE COUNTY I I - _ - ( I I _ _ _ I ; I NRI Q 1 �RESLTOWNHOUSES I I ^ p® CIAB� ��M SWR NM RPItIAND JILS ENGINEERING, LLC om BW REEWAY• 9N . (D Hmtm To M74 SONE: AR -AG. RES. ^\ BUTTE COUNTY / / ZONE: AR -AG. BUTTE COUNTY NTIAL RES. ZONE: AR -AG. RES. \ I BUTTE COUNTY I BUR" COUNTY �` , Ph— Dm Rrftese Fu TTSTI R Mfl . ' I ZONE: AR -AG. RES. / SURE COUNTY I I (ZONE: R{ \ SONE: AR -AG. RES. ZONE: AR -AG. RES. RESIDENTIAL 1OWNHOUSES BORE COUNTY BUTTE COUNTY BUTTE COUNTY I F I W EPIC .n .ane..... i u' s `tx0'm WN sort I'm rmsw. a oslUo - — -I PROPERtt UNE 658'-7' IFf-A; DESCPRIPTION: 1 I ' +I EXIST LANDSCAPING7 ALL THAT CERTAIN REAL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, Cltt OF CHICO. DESCRIBED nl AS FOLLOWS:TAX i 1] • �I l'IEXISTI130'(!) T- 8111081LE U TOWER GG IWUFARROPPOESED ANTENNAS 1 ( 1 A YM 42.. PARCEL LOT[ EXISTIN197. BLOCK 07 G NIC TEMPLE 333 % ZONING j ZONE: A-5 AGRICULTURAL BUTTE COUNTY 1 I I 1 SITE ENTRY I _ _ 1 ADJACENT ZONING SONE: S -R-1/2 SUBURBAN RESIDENTIAL SURE COUNTY — _ _ — _ _ — _ _ _ - ADJACENT ZONING _ _ , w O I 1 EXSf. 1 I 1 ZONE: S -R-1/2 SUBURBAN RESIDENTIAL BUTTE COUNTY n PARKWG LJ] '--� • 1 1 I EXISTING LOT 7 1 I 78t C] 9 ADJACENT ZONING ZONE: A-5 AGRICULTURAL b ~ 1 - - 57'-7' GARAGE - -PROPERTY UNE 688' 60t• -e'! 1 t \ \ I\ � U W �% = BUTTE COUNTY I 7•_Tf \ " \ LEASE AREA \ I EXISTING LANDSCAPING \ \ n G - I. ADJACENT ZONING ZONE: A-5 AGRICULTURAL BUTTE COUNTY \ \ N Z oC z NORD -_ AVE. ______-_____-__� � \ \ A-1 SITE PLAN SITE PLAN ® SCALE:1'= 100'-0" (11 ii SIZE) 1 REV SIGN o Ce clearw're® - sme u%L rAalclo,I mro K sunT 1.1oP XIIIIID f1O01] - EXISTING 0 NJ Y ENGINEERING, LLC • ANTENNAS WOO 1111 WAY. 11110 JIM 11�OtOA T z TWT. ' EXISTING MW DISH :eao RIW r *& Fu M T262we ANTENNA EXISTING 4' � NG PANEL WIDE MAN / ANTENNAS ANTE GATE. I PROPOSED CLEMM7RE (4) ePlc . Mc 1.6 SECTOR ANTEMNA ARRAY W/1 a ]e, S LIXMrtfON OR. FUTURE. RC O 113' (t) 7EXISTING I ' PROPOSED (4) CLEARWRE. a• MICROWAVE ANTENNAS O 1,8 a PY]0 _ L' ExfST. 110• (t) vt •' CONC. SUB 7 1 I 1 00 TING GARAG LLJ 1 = EXISTING 130'(*) m O T -MOBILE LATTICE TOWER (DESIGNED BY OTHERS) EXISTING 6' HIGH CHAIN- UNK FENCE W/3 STRANDS w OF BARBED WIRE. : ^ O n Q U EXISTING z p UTILITY H -FRAME EXISTING 130'(*) T -MOBILE - F" Y LATTICE TOWER W/ 1 PROPOSED CLEARWIRE U) ; Q Q o EXISTING EQUIPMENT (4) SECTOR ANTENNA A-1 Lo u CABINETS (BY OTHERS) ARRAY R (4) MICROWAVE ANTENNA SEE NOTE BELOW PROPOSED CLEARWRE COAX 2 CABLE CONDUIT W/ SHROUT a 1O RUN ON CONIC. SLAB. PROPOSED CLEARWRE ' CABINET. ON EXISTING e - EXISTING FIR TREE CONCRETE SLAB i 13'-(r 11-0111'- EXISTING GARAGE (BEYONDCLEA 00 ? SITE) EASE ARE LL �� x._ CABNEf ONCE%X.. e OCONCRETE u EXISTING FENCED AREA SULK 0 NDTE: NEW GPS ANTENNA MOUNTED ] LOCATE MW ANTENNAS ON EXISTING CONCRETE 3 L,.1 u ' 1' MW DISH AZI O 16 SLAB E-1 tL' 2' MW DISH AZI O 69' EXISTING 6' HIGH CHAIN- I>Inn In • V MW DISH AZI O 131' LINK FENCE WITH (3) - • 2' MW DISH AZI O 266. STRAND BARBED VIRE 0 SEE DTL 6/A-4 FOR ANTENNA ORIENTATION EXISTING UTILITY H -FRAME A-2 ^ EXISTING EQUIPMENT EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) ENLARGED SITE PLAN AND ELEVATION ® SCALE: 1/4' = 1'-0' (24x36 SIZE) 1 WEST ELEVATION -0 SCALE: 1/8' = 1'• (24x3s slzE) 2 REVISION 1 0 ENLARGED SITE PLAN SCALE: 1/8' = 1'-0' (11x17 SIZE) SCALE: 1/16"= 1'-0' (11x17 SIZE) EAST AVE./T..MOBILE CA-CHC011 PROJECT DESCRIPTIONS CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (8) ANTENNAS (FOUR (4) PANEL & FOUR (4) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNAS AND A SITE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. SITE INFORMATION PROJECT CONTACTS SITE ADDRESS: 1110 W. EAST ROAD ARCHITECT/ SAM LAMENDOLA Mobile® CHICO. CA 95926 ENGINEERING: MAX ENGINEERING, LLC A-2 ENLARGED SITE PLAN AND SOUTH 9000 SOUTHWEST FREEWAY ATC SITE®: CA—CHC011 5508 LAKE WASHINGTON BLVD, SUITE #410 381 S. LEXINGTON DR. 19807 N. CREEK PARKWAY N. HOUSTON, TX 77074 PARCEL NUMBER: 042-070-197 BOTHEL, WA 98011 MOBILE: (717) 873-0466 LATITUDE: 39' 44' 45.5" N GENERAL CONTACT: DAVID WILTSEE U 0 0 W EPIC WIRELESS GROUP 381 SOUTH LEXINGTON DR. LONGITUDE: 121' 52' 56.1" W SUITE #103 FOLSOM, CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (530) 878-9117 dwiltsee@sbcglobal.net ELEVATION: 167' AMSL i SITE OWNER: T—MOBILE CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF o: TELECOMMUNICATIONS PHONE: (425) 398-7550 FACILITY 0 PROPERTY OWNER: LELAND STANDFORD MASONIC PROPOSED USE: TELECOMMUNICATIONS z TEMPLE ASSOCIATION FACILITY P.O. BOX. 784 CHICO, CA. 95927 POWER: PG & E PHONE: (530) 342-7143 TELCO: AT&T JURISDICTION: BUTTE COUNTY cr ZONING: A-5 AGRICULTURE APPLICABLE CODE: 2001 CALIFORNIA BUILDING 0 2 STANDARDS CODE CONSTRUCTION TYPE: V—N OCCUPANCY TYPE: ' UNOCCUPIED Uj PROJECT AREA: 49 SO. FT. PROJECT TEAM VICINITY MAP SITE ���.... 43, I DRIVING DIRECTIONS 1 i i FROM FOLSOM, CA, TAKE BARTON ROAD NORTH —TURN LEFT (WEST) ON ROCKLIN ROAD —TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES —TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES t —TURN RIGHT (NORTHWEST) ONTO SR 65 (G STREET) AND GO 20 MILES. —SR 65 BECOMES HWY 70, CONTINUE ON HWY 70 APPROX 37 MILES —EXIT INTO SR 149 AND GO APPROX. 4.6 MILES —MERGED INTO SR99, GO APPROX. 13 MILES. —TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO APPROX. 1.8 MILES . —SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. I e a r w 'r ® MAX ENGINEERING, LLC 'k—c f ®® T a m Mobile® GENERAL NOTES 9000 SW FREEWAY, Ste • 410 SITE PLAN A-2 ENLARGED SITE PLAN AND SOUTH Houston, Texas 77074 EPIC WIRELESS GROUP, INC. EQUIPMENT DETAILS 5508 LAKE WASHINGTON BLVD, ANTENNA DETAILS 381 S. LEXINGTON DR. 19807 N. CREEK PARKWAY N. SUITE 300 Phone (713) 773-2525 SUITE #103 BOTHEL, WA 98011 KIRKLAND, WA 98033 Fax (713) 773-2558 FOLSOM, CA 95630 o � C � r. r.. . ata f,�:�''1 t��{�i �'a'-•;.� DRAWING INDEX SHEET CONTENTS T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN AND SOUTH ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS E-1 GROUNDING PLAN AND DETAILS At all new services & grounding trenches, provide "WARNING" tope of 12" below grod �/ "CALL BEFORE YOU DIG" 1-800-227-2600 CALIFORNIA UNDERGROUND SERVICE ALERT NORTH THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. 'q� A clearw're° 5608 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste • 410 Houston Texas 77074 Phone 1713t 773-2626 Fax 1713) 773-2668 fl - EPIC WIRELESS GROUP. INC. 381 S. LEXINGTON DR. Sur1E 8103 FOLSOM, CA 95630 W to 0 I n n O o � U 0 0 W U T- I TITLE SHEET AND GENERAL INFORMATION REVISION 0 to n n 0 z 0 i o: 0 z O L) cr L 0 2 Uj w N 0 T- I TITLE SHEET AND GENERAL INFORMATION REVISION 0 clearw're° 5806 LAKE WASIaNG7ON BLVD NE GENERAL NOTES: ABBREVIATIONS: SDS 1300 KIRKLAND. WA 98033 ADJ ADJUSTABLE MAXENGINEERING, LLC 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING & AND 9000 SW FREEWAY, Bte • 41D SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY; IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON APPROX APPROXIMATE Houston, Texas 77074 a UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE O BTS AT Phone 1719) 779-2626 INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS OCCURRED DUE 70 CONSTRUCTION ON OR ABOUT THE PROPERTY. CAB BASE TRANSMISSION STATION CABINET Fax 1716)N DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS CLG CEILING ��•• AND OWNER'S PROJECT MANUAL. 17. THE ARCHITECTSENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE /ENGINEERS CONC CONT CONCRETE CONTINUOUS CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. DIA OR DIAMETER 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR DWG DRAWING EPIC WIRELESS GROUP. INC. WATER OR SEWER SERVICE. OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EA EACH 381 S. LEXINGTON OR EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ELEC ELEV ELECTRICAL ELEVATION SUITE /103 3. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE EQ EQUAL FOLSOM. CA 95630 HANDICAP ACCESS IS REQUIRED). RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY EQUIP EQUIPMENT CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S EGB EQUIPMENT GROUND BAR 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE (E) EXISTING DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM. SITE EXT EXTERIOR SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARWIRE, LLC. MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. FF FINISHED FLOOR STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY GA GAUGE THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO GALV GALVANIZED MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO, AND AVOID DISTURBING NORMAL BUSINESS. GC GENERAL CONTRACTOR APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH GRND GROUND CONSTRUCTION. LG LONG 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CAUFORNIA FOR MAX MAXIMUM UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. MECH MECHANICAL MFR MANUFACTURER 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE MGB MASTER GROUND BAR w CONSTRUCTION OPERATION. MIN MINIMUM MTL METAL 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND NIC NOT IN CONTRACT INSPECTIONS REQUIRED FOR CONSTRUCTION. NTS OC NOT E SCALE ON CENTER O OPP OPPOSITE 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY PCS PERSONAL COMMUNICATION SYSTEM BASIS. SF SQUARE FOOT SHT SHEET LI 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SIM SS SIMILAR STAINLESS STEEL \ SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED STL STEEL --I W PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE TOC TOP OF CONCRETE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM TOM TOP OF MASONRY TYPICAL N U THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH TYP VIF VERIFY IN FIELD (71 N CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO LI UN O UNLESS OTHERWISE NOTED = o, � THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. WWF WELDED WIRE FABRIC a Y) � 3� W/ WITH O o 0 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED W U U BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE o CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL n CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. o it. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO Z 0 MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE 1— LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12, ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN z N o STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND 0 v ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, cr O ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, I` MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE w JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. N 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT o TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE-RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. G-1 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. GENERAL NOTES REVISION 0 ADJACENT ZONING ZONE: AR—AGRICULTURAL RESIDENTIAL BUTTE COUNTY ADJACENT ZONING ZONE: A-5 AGRICULTURAL BUTTE COUNTY SITE PLAN ZONE: AR -AG. RES. I I ZONE: AR -AG. RES..' ZONE: AR -AG. RES. I I ZONE: R4 BUTTE COUNTY I I BUTTE COUNTY I BUTTE COUNTY I (RESIDENTIAL TOWNHOUSES I I I I BUTTE COUNTY 1 h -• - - - • • - - + - - I - - - - - - I I ZONE: R4 I � I I I RESIDENTIAL TOWNHOUSES I Q ZONE: AR—AG'. RES. \ ZONE: AR—AG. RES. ZONE: AR—AG. RES \ BUTTE COUNTY BUTTE COUNTY '- BUTTE COUNTY I BUTTE COUNTY U I Lu W ' ZONE: AR—AG. RES. ZONEAR—AG. RES. ZONE: AR—AG. RES. ZONE: R4 BUTTE COUNTY [BUTTE, COUNTY BUTTE COUNTY (RESIDENTIAL TOWNHOUSES JBUTTE COUNTY — IPROPERTY LINE 656'--7" EXIST LEGAL DESCPRIPTION: I + +I LANDSCAPING l ALL THAT CERTAIN REAL PROPERTY I ^ I dr) SITUATE IN THE STATE OF CALIFORNIA, �/CITY OF CHICO. DESCRIBED AS FOLLOWS: W Lai z 1 TAX PARCEL ID: I J MAP 42, LOT 197, BLOCK 07 I I Z R-11/26"SUBURBAN RESIDENTIAL Z EXISTING BUTTE COUNTY MASONIC 0 I a EXISTING 130 (t) T— TEMPLE cr ¢ (MOBILE LATTICE TOWERNIN I OL SITE ENTRY OL W/PROPOSED �RWI j ZONE: A-5 AGRICULTURAL (ANTENNAS BUTTE COUNTY 1 A I ADJACENT ZONING ZONE: S—R-1/2 SUBURBAN RESIDENTIAL b� i; H clearw'reO 5608 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC WOO SW FREEWAY, Ste • 410 Roustoa Texas 77074 Phone (719) 773-2625 Fax (713) 773-2668 .09 1 IL. WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SURE 0103 FOLSOM. CA 95630 m BUTTE COUNTY XIST. I PARKING I EXISTING LOT7 I I n GARAGE 1 1 - PROPERTY UNE 666' (+/—) 1 -7" 601'-T±: 1 \ 1 W T-� �� AREA \LEASE z EXISTING • LANDSCAPING - \ \ 0 \ \ ADJACENT ZONING ZONE: A-5 AGRICULTURAL BUTTE COUNTY \ U Of OfH- V% z NORD AVE. z 0 0 cr SCALE: 1" = 50'-0" (24x36 SIZE) o SCALE: 1" = 100'-0" (11x17 SIZE) clearw'reO 5608 LAKE WASHINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC WOO SW FREEWAY, Ste • 410 Roustoa Texas 77074 Phone (719) 773-2625 Fax (713) 773-2668 .09 1 IL. WIRELESS GROUP. INC. 381 S. LEXINGTON DR. SURE 0103 FOLSOM. CA 95630 SITE PLAN REVISION 0 m I- I n C •--1 O j \ `J I 0 (XCN D_' N rn Q o O W U �� SITE PLAN REVISION 0 m n 1. O z 0 U Of OfH- V% z z 0 0 cr o LLJ W all V) U) 0 SITE PLAN REVISION 0 EXISTING UTILITY H -FRAME EXISTING EQUIPMENT CABINETS (BY OTHERS) ENLARGED SITE PLAN clearw're® shoe INCE wASmINGTON BLVD NE SUITE /300 KIRKLAND. WA 98033 EXISTING OMNI ANTENNAS MAX ENGINEERING, LLC . MM SW FREEWAY. Ste • 00 _ Houston Texas 77074 - - Phone 013) 779-2525 EXISTING MW DISH Fax 1713) 773-2558 ANTENNA EXISTING 4' i� •�'• WIDE MAN / EXISTING PANEL GATE. ANTENNAS � -/- —x --x— x- x- X- x- X ' PROPOSED CLEARVARE (4) EPIC WIRELESS GROUP. INC. SECTOR ANTENNA ARRAY W/1 1'6 381 S. LEXINGTON DR. EXISTING n FUTURE, RC O 113 (t) A-4 SUITE /103 ti. ' COAX - I F'OLSOM. G 95630 . SHROUD .> PROPOSED (4) CLEARVIIRE 1.6 MICROWAVE ANTENNAS O A_4 oEXIST. 110' (t)CONC - Q .SLAB 7 f 0 EXISTING 6' HIGH CHAIN- LINK FENCE W/3 STRANDS OF BARBED WIRE. EXISTING 130'(1) T -MOBILE LATTICE TOWER W/ PROPOSED CLEARWIRE 1 (4) SECTOR ANTENNA A-4 ARRAY do (4) MICROWAVE ANTENNA. $SEE NOTE BELOW PROPOSED CLEARWIRE COAXEE CABLE CONDUIT W/ SHROUT RUN ON CONIC. SLAB. P CLEARWIRECABINET ON NG CONCRETE SLAB A-3 T -O' CLEARWIRE AND ELEVATION LEASE AREA 0 34'-0' t PING FENCED AREA NOTE: LOCATE MW ANTENNAS 1'MW DISH AZI O 16' 2' MW DISH AZI ® 89' 1' MW DISH AZI O 131' 2' MW DISH AZI 0261r. n SEE DTL 6/A-4 FOR ANTENNA ORIENTATION SCALE: 1/4" = 1'-0" (24x36 SIZE) WEST ELEVATION SCALE: 1/8" = 1'-0" (11x17 SIZE) EXISTING EQUIPMENT EXISTING 130'(±) T -MOBILE LATTICE TOWER (DESIGNED BY OTHERS) EXISTING FIR TREE EXISTING GARAGE (BEYOND SITE) PROPOSED CLEARWIRE e CABINET ON EXISTING A-3 CONCRETE SLAB NEW GPS ANTENNA MOUNTED e ON EXISTING CONCRETE SLAB E-1 EXISTING 6' HIGH CHAIN- LINK FENCE WITH (3) STRAND BARBED WIRE EXISTING UTILITY H -FRAME EXISTING TOWER FOUNDATION (DESIGNED BY OTHERS) SCALE: 1/8" = 1'-0" (24x36 SIZE) I I SCALE: 1/16" = 1'-0" (11x17 SIZE) 2 A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 MW E- n O 1 z I O m tL N I—� a U 3 0 Q o (� ul: A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 n n 0 z 0 U rr (n U) z o O c 0 L] w cn N 1-11 i it A-2 ENLARGED SITE PLAN AND ELEVATION REVISION 0 A r=i 0 f ESTES ROAD / SBA CA-CHCO07 PROJECT DESCRIPTIONS CLEARWIRE (CW) PROPOSES TO APPEND AN EXISTING CELLULAR FACILITY BY THE ADDITION OF (7) ANTENNAS (FOUR (4) PANEL & THREE (3) MICROWAVE) TO AN EXISTING LATTICE TOWER WITH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE ANTENNAS AND A SITE,SUPPORT CABINET NEAR. THE BASE OF THE SAME TOWER. SITE INFORMATION PROJECT CONTACTS SITE ADDRESS: ESTES ROAD ARCHITECT/ SAM LAMENDOLA CHICO, CA 95928 ENGINEERING: MAX ENGINEERING, LLC E-1 9000 SOUTHWEST FREEWAY SITE ID ESTES ROAD SUITE #410 PARCEL NUMBER: 039-4011 HOUSTON, TX 77074 MOBILE: (717) 873-0466 LATITUDE: 39' 42' 56.9" GENERAL CONTACT: JOSH JORDAN O EPIC WIRELESS GROUP 381 SOUTH LEXINGTON DR. LONGITUDE 121' 50' 13.2" SUITE #103 FOLSOM, CA 95630 LAT/LONG TYPE: NAD 83 PHONE: (916) 984-5928 00 josh.jordon@epicwireless.net ELEVATION: 184.00' m Cn SITE OWNER: SBA NETWORK SERVICES CURRENT USE: TELECOMMUNICATIONS ONE TOWN CENTER, 3rd FLOOR FACILITY BOCA RATON, FL 33486 } 1 CONTACT; MATT HAZARD PROPOSED USE: TELECOMMUNICATIONS PHONE: (360) 601-6100 FACILITY POWER: PG & E TELCO: AT&T JURISDICTION: CITY OF CHICO ZONING: r I 4 APPUCABLE CODE: 2001 CALIFORNIA BUILDING v Orre�- STANDARDS CODE �� CONSTRUCTION TYPE: V -N ' '"`r� OCCUPANCY TYPE: UNOCCUPIED PROJECT AREA: 49 SO. FT. PROJECT TEAM VICINITY MAP �t PY„ S eBab if -... I W rh uiros ' I App VA CL -E1' LN DRIVING DIRECTIONS -FROM FOLSOM, CA TAKE 1-80 TOWARDS SACRAMENTO -EXIT INTO 1-5 SOUTH -TAKE RAMP ONTO SR -36/ SR -99 (CA-99/CA-36 CHICO) -KEEP STRAIGHT ONTO SR -99 (ANTELOPE BLVD.) -TURN RIGHT ONTO RAMP (CA -32/ CHESTER/ ORLAND) -TURN LEFT ONTO W 8TH ST. -TURN LEFT ONTO CHERRY ST. -DRIVE THRU W 9TH ST. INTERSECTION AND TURN RIGHT ON DAYTON RD. -FOLLOW TO DEAD END, DRIVE AROUND BARRACADES AND TURN LEFT ON GRAVEL ROAD. -TOWER IS LOCATED APPROX. 1'/2 MILE ON EAST SIDE OF RR TRACKS m e ® MAX ENGINEERING, LLC dearw"rtz 9000 SW FREEWAY, Ste a 410 f'SBA Houston, Texas 77074 EPIC WIRELE89 GROUP, INC. 5508 LAKE WASHINGTON BLVD, Phone (713) 773-2525 381 S. LEXINGTON DR. ONE TOWN CENTER SUITE 300 SUITE #103 3rd FLOOR KIRKLAND, WA 98033 Fax (713) 773-2558 FOLSOM, CA 95630 BOCA RATON, FL 33486 DRAWING INDEX SHEET CONTENTS T=1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN AND ELEVATION A-3 EQUIPMENT DETAILS A-4 ANTENNA DETAILS E-1 GROUNDING PLAN AND DETAILS At all new services & grounding trenches, provide 'WARNING" tapesat 12' below grade. C -T_., IL, j "CALL BEFORE YOU DIG" 1_800_227_2600 CALIFORNIA UNDERGROUND SERVICE ALERT NORTH THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLEARWIRE SERVICES IS STRICTLY PROHIBITED. clearw're® 5808 LAKE WASKNGION BLVD NE SURE #300 KIRKLAND, WA 98033 MAX ENGINEERING, LLC 8000 8W FREEWAY. Ste • 4t0 HouetoR Texee 77074 Phmre 17181 773-2526 Fax mW TM2668 .06-1 IC vn"ELE®e BROUP, 381 S. LEXINGTON DR. SUITE #103 FOLSOM. CA 85630 N m M� W O o, U " rn L o °� Wyr � 00 1 m Cn Q ~ U W U U1 U } 1 z N T I TITLE SHEET AND GENERAL INFORMATION REVISION 1 0 m 0 n 0 z 0 U Cn " _O � o w N N 0 T I TITLE SHEET AND GENERAL INFORMATION REVISION 1 0 GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE _PRECEDENCE; THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL - INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. S. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY PACIFIC TELECOM SERVICES, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO, AND APPROVED BY, CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12, ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, . ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13, THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR -2-A1 OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPRUVLMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF. NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. ABBREVIATIONS: ADJ APPROX BTS CAB CLG CONC CONT DIA ORO DWG EA ELEC ELEV EQ EQUIP EGB (E) EXT FF GA GALV GC GRND LG MAX MECH MFR MGB MIN MTL NIC NTS OC OPP PCS SF SHT SIM SS STL TOC. TOM TYP VIF LION WWF W/ ADJUSTABLE AND APPROXIMATE AT BASE TRANSMISSION STATION CABINET CEILING CONCRETE CONTINUOUS DIAMETER DRAWING EACH ELECTRICAL ELEVATION EQUAL EQUIPMENT EQUIPMENT GROUND BAR EXISTING EXTERIOR FINISHED FLOOR GAUGE GALVANIZED GENERAL CONTRACTOR GROUND LONG MAXIMUM MECHANICAL MANUFACTURER MASTER GROUND BAR MINIMUM METAL NOT IN CONTRACT NOT TO SCALE ON CENTER OPPOSITE PERSONAL COMMUNICATION SYSTEM SQUARE FOOT SHEET SIMILAR STAINLESS STEEL STEEL TOP OF CONCRETE TOP OF MASONRY TYPICAL VERIFY IN FIELD UNLESS OTHERWISE NOTED WELDED WIRE FABRIC WITH clearw'.re° 5808 LAKE WASHIM N BLVD NE SUITE J300 KIRKLAND. WA 98033 MAX ENGINEERING, LLC 8000 8W FREEWAY, ata • 410 Houston Taxes 77074 Phone m3) 773-4948 Fax (713) 773-2568 .00-1 IU M RELee9 GROUP. 381 S. LEXINGTON DR. SURE 0103 FOLSOM. CA 95630 G-1 . GENERAL NOTES REVISION 0 to 0 n r 1 N V Ln cn o °' W oa 0 i or V l U W U W U G-1 . GENERAL NOTES REVISION 0 to 0 n 0 z 0 U u L) _O o Ldo En to rn 0 G-1 . GENERAL NOTES REVISION 0 ZONING / ZONE: AGRICULTURAL A-20 T \ \ ♦ USE: AGRICULTURAL ZONING ZONE: AGRICULTURAL A-20 / USE:, AGRICULTURAL 03� AnOq ZONE: AGRICULTURAL A-20 / \F`J} USE: AGRICULTURAL / \ \ 1 ' \-to \ \ I JV 0 / ADJACENT APARTMENTS Ji Q0 o Q� ADJACENT ZONING Ld / EXISTING TREE ZONING J ZONE: HEAVY INDUSTRIAL M-2 / USE: HEAVY INDUSTRIAL LINE (TYP.) ZONE: AGRICULTURAL A-20 USE: AGRICULTURAL / 0 /w e EXISTING SBA FENCED COMPOUND WITH PROPOSED 7'x7' WIR CL ARE LEI�SE AREA EXISTING 220.0' LATTICE 4 EXISTING TREES (TYP.) \ ( I TOWER WITH PROPOSED 1 / I I CLEARWIRE ANH NNAS ' / I I EXISTING GRAVEL/ I DIRT ROAD / -/ -- -- -- -- -PROPERTY UNE -- -- -- -- -- -- -- -- -- --L - -- UNION PACIFIC RAILROAD -- -- -- -- -- PROPERTY LINE -- -- -- -- -- -- -- -- -- ZONING ZONE: AGRICULTURAL A-20 USE: AGRICULTURAL . SITE PLAN • I• .I SCALE: 1'= 60'-O" (24"x36" SCALE: -1" = 120'-0" (11"x17" 1 clearw*re® 5809 LAID: WASHING= BLVD NE SUITE 8300 KIRKLAND, WA 98033 MAX ENGINEERING, LLC 9000 SW FREEWAY, Ste v 410 Houetoq Texae 77074 Phone (7131773-2626 Fax (713) 773-2688 '90-1 IG Wiwe�ee oaour. 381 S. LEXINGTON DR. SUITE 8103 ` FOLSOM. CA 95630 A. I SITE PLAN REVISION 0 co M� W cn C Q 0 0 O Go N cx c U 06 W' I cn I/I W U W U W I% A. I SITE PLAN REVISION 0 co C 0 r` 0 Z 0 U o z O � w 0 W o � w cncn 0 A. I SITE PLAN REVISION 0 1T1 x Z m z� MO 37'-6" ci r m Z 0 m �X—XX—XXX mx m Y \ x Z i N / > x I 0 L_ x m 71 pmm x cn ND x ADX O z �m mP1 z n r N LEASE AREA w v x { m 0 m x I 3 -- � � xz— �m4 �m x cv0i I x vLA x m x X X DOZS`� x D z �NN x N � Z m o m �z'� z Df0—/I�p� x ` Z C r OS C� mm Z D Fn 7- I X X X D m m D cn W m --I z Om l �f O D fA !n z v .—m AZI PANEL (7 C7 �vmi _ �^ �c�m m^ v^ c�z �wC Som m ANT 0 mm o\ XZ— om"���"Z x! ��� Z _� mm m u II �o mZz �� o �onxmA Azo b b yOy z oo� m m� ecojz 0 ANT 180 A ya G mZ � 0\ mpzZ > Z a n \ nv ppy33y (n D Kp O z Z 1�1 m p � m rn g j N Ln D N! 2 to- s m.Nm. w to z rn W m T— m D O Z 220'(±) AGL TOP OF EXISTING LATTICE TOWER AGL RAD CENTER OF PROPOSED CLEARWIRE ANTENNAS -ZX DX �x �` �x �x 2px QUI Z�� F: mz m� Z D�� _� mm� m -a WZGZ7 m� 1 zo ��� D zG) 00 NCO Z> Z. N Q �i'Q ��CJJ v v In �mO1 mr _ 0 o c Zv 3" NN D m `—z 0 m W z v Z m o O m vS OHO iA f K = mo r !A (A ^� mm _, G z yr s z 0 D mmil apv m II II z zN� Q O O O p q x N N m m IV REVISIONS 0 1 ISSUED FOR CONSTRUCTION 07/10/06 ESTES ROAD / SBA CA-CHCO07 ESTES ROAD CHICO, CA 95928 m iX =x 2: U) Z Dm �p OOp Z- my N3 N Z x m D n yg � x No G N N FG M f0 . i O x � \ V c C R m g 2 C$ S(D a rl I m • 131111111115� VICINITY MAP ® clearWre® EAST AVE IT -MOBILE S� \� 1`' til°l. '9 L, _�' �� Q¢� :{.. MAX ENGINEERING, LLC I, UC \Vk, ds°�s . WOG 9w 71mtOA NFEWAY, M. 4° Tu )1074 . M7 00 CA-CHCO11 Qh Y FA - • �' StP O EVIL ., """"'°""' PROJECT' DESCRIP'T'IONS/a ` CLEARWIRE (CW) PROPOSES'TO APPEND AN EXISTING CELLULAR FACILITY BY THE OF (8) ANTENNAS (FOUR (4) PANEL R FOUR (4) MICROWAVE) TO AN ADDITION WI EXISTING LATTICE TOWER TH BTS EQUIPMENT MOUNTED DIRECTLY BEHIND THE `�A.� - ;. �(� SITE00 `~�`v.rr4- rp50u, G G!4]0 aAa \ ANTENNAS ANDA 9TE SUPPORT CABINET NEAR THE BASE OF THE SAME TOWER. j� l � Y�r SITE INFORMA'T'ION PROJECT CONTACTS '�eA fi�'n%o4r"�� s yes ' SITE ADDRESS: 7110 w. EAST ROAD ARCHITECT/ SAM IAMENDOLA - 9� CHICO. CA 95926 ENGINEERING: MAX ENGINEERING. LLC 9DOO SOUTHWEST FREEWAY x :±. 1i'- �:7• i "�.i ATC SITE/: CA-CHC011 SUITE /410 .1 'B 4 'p�: ' HOUSTON, TX 77071 PARCEL NUMBER: 042-070-197 MOBILE: (717) 873-0466 _ _ ;✓' �. E GENERAL CONTACT: DAVID WILTSWIRELESS LATITUDE: 39' 44' 45.5' N 1 EPIC WIRELESS CROUP N �} ✓f g 'I `t•F• V���.�' O LONGITUDE: 121' 52' 56.1" w SUI SOUTH LEXINGTON DR. SUITE . FOLSOC PHONE:I, CA95630678 LAT/LONG TYPE: HAD 83 PHONE: (330) 878-8117 ' DRIVING DIREC fIONS DRAWING INDEX dwiltsee®sbcglobol.nel ELEVATION: 167' AMSL SITE OWNER: C NOBRE CURRENT USE: MASONIC TEMPLE/ CONTACT: DIANE TARDIFF TELECOMMUNICATIONS PHONE: (425) 398-7550 -FROM FOLSOM, LA, TAKE BARTON ROAD NORTH -TURN LEFT (WEST) ON ROCKLIN ROAD SHEET CONTENTS > 6 � e ¢ X FACILITY 7-1 TITLE SHEET AND GENERAL INFORMATION i° L PROPERTY OWNER: LELAND STANDFORD MASONIC PROPOSED USE: TELECOMMUNICATIONS -TUNRN RIGHT (NORTH) ON SIERRA COLLEGE ROAD AND TRAVEL NORTH APPROX. 7.9 MILES U s U) TEMPLE ASSOCIATION FACILITY P.O. BOX 784o G-1 GENERAL NOTES I d �' CA. 95927 POWER: PG Q E PHONE: (530) 342-7143 -TURN LEFT (WEST) ONTO SR 193 AND DRIVE 3 MILES A-1 SITE PN PLAN B U TELCO: AT&T GO 2U MILEHS (NORTHWEST) ONTO SR 65 (G STREET) AND A-2 ELLYATON SITE PLAN AND SOUTH JURISDICTION: BUTTE COUNTY -SR 65 BECOMES HWY 70. CONTINUE ON HWY 70 APPROX A-3 EOUIPMENT DETAILS o ZONING: A-5 AGRICULTURE 37 MILES -EXIT INTO SR 149 AND GO APPROX. 4.6 MILES A-4 ANTENNA DETAILS n APPLICABLE CODE: 2001 CALIFORNIA BUILDING STANDARDS CODE -MERGED WTO SR99, GO APPROX. 13 MILES. E -i GROUNDING PIAN AND DETAILS Z . COONSTRUUCCTION O�TITYPE: V-NCCU 'PT.EO - 49 p -TURN LEFT (SOUTHWEST) ONTO EAST AVENUE AND GO APPROX. 1.0 MILES PROTECT AR EA: 50. -SITE IS A LATTICE TOWER AT CORNER OF NORD AVE. AND W. EAST AVE. Z O W C C j PROJECT TEAM At all new services h grounding trenches. provide "WARNING' lope at 12- below c MAX ENGINEERING, LLC ...T..Mobile' .� BEFORE DIG' clearw°re° L 1-800-227-2600 8006) 0 SW FREEWAY, Ste m 410 EPIC wIR¢l.eee ORauv, INC. CALIFORNIA UNDERGROUND SERVICE ALERT NORTH GROUND VICEA T-1 Houston, Texas 77074 19807 N. CREEK PARKWAY N. 5508 LAKE WASHINGTON BLVD. 381 S. LEXINGTON DR. - SUITE 300 Phone (713) 773-2525 SUITE #103 BOTHEL, WA 98011 TITLE SHEET AND GENERAL INFORiMTgN THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS KIRKLAND. WA 98033 Fax (713) 773-2558 FOLSOM, CA 95630 REVISION 1 0 • PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLFARWIRE SERVICES IS STRICTLY PROHIBITED. GENERAL NOTES: I. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY. UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT. LABOR. AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNERS PROJECT MANUAL. 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. S. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 4. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY CLEARWIRE, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO. AND APPROVED BY. CLEARWIRE PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SMALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS. OMISSIONS. OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 10. THE CONTRACTOR SMALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS. TECHNIQUES. SEQUENCES. AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. IT. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE .. LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES. REGULATIONS. AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS. ORDINANCES. RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY. MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS. AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 10. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH ARATING OF NOT LESS THAN 2-A OR 2-A108C WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. g0 Lr !n Z O LJ o cc j N 0 G-1 GENERAL NOTES REVISION 1 0 clearw're® ee°e UEE •A9m6TIN &t K[ ABBREVIATIONS: wa NII NRXwm. u °eau ADJ ADJUSTABLE MAX ENGINEERING, LLCh 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS 70 PROTECT EXISTING AND WW ITIN RFSWAY. y„ m IMPROVEMENTS, EASEMENTS. PAVING. CURBING. ETC. DURING CONSTRUCTION. UPON APPROX APPROXIMATE H—tm T-77071 COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE C AT PI— —7Tb s OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. BTS CAB BASE TRANSMISSION STATION CABINET Fu D1e17Te-ee69 CLG CEILING �.••• 17. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONT CONT CONCRETE CONTINUOUS CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. DIA OR DIAMETER CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR DWG DRAWING OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT ELEC Mel 5. u:XwcloN oR. EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN EL EC ELEV ELECTRICAL ELEVATION sunt F1OJ ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE 81DOER SHALL BEAR THE EO EQUAL f0�O1• E'` 0e6°0 RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY EQUIP EQUIPMENT CONFLICTS. ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S EGB EQUIPMENT GROUND BAR PROPOSAL IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE (E) EXISTING EXTERIOR MORE COSTLY OR EXTENSIVE WORK. UNLESS DIRECTED OTHERWISE. EXT FF FINISHED FLOOR GA GAUGE 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO GALV GALVANIZED AVOID DISTURBING NORMAL BUSINESS. GC GRND GENERAL CONTRACTOR GROUND LAUJ( LONG 19. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA) IN CALIFORNIA FOR MAXIMUM UNDERGROUND UTILITY UARKOUT PRIOR TO CONSTRUCTION. 1-800-227-2600. MECH MECHANICAL " MFR MANUFACTURER MGB MASTER GROUND BAR W MIN MTL MINIMUM METAL NIC NOT IN CONTRACT HIS OC NOT 70 SCALE ON CENTER O OPP OPPOSITE - �•-• PCS PERSONAL COMMUNICATION SYSTEM rG SF SQUARE FOOT . SHT SHEET TI E� ' SIM SIMILAR ' SS STAINLESS STEEL STL TOC TOPE OF CONCRETE TOM TOP OF MASONRY TYPICAL U ' TYP VIF VERIFY IN FIELD UNLESS OTHERWISE NOTED n LION WWF WIRE FABRIC U W/ WELDED 3:S W U �� g0 Lr !n Z O LJ o cc j N 0 G-1 GENERAL NOTES REVISION 1 0 7(wE: AR-AG. RES. I I ZONE: AR-AG. RES. ZONE: AR-AG. RES I I ZONE: R{ I clearw're® ADJACENT ZONING BUTTE COUNTY I I I BUTTE COUNTY I BUTTE COUNTY I I RESIDENTIAL TOWNHOUSES I I BUTTE COUNTY I I IAu � &m K suTlE Iwo YlOI] ENGINEERING, LLC ZONE: AR-AGRICULTURAL _ _ _ _ I _ _ _ - _ _ I I RESIDENTIAL _ _ _ _ ; I o00 gW RFENAY, BN • IID BUTTE COUNTY ZONE: RI Q I 1 IMAX 11 tp TYLIA TRDI ' IZONE: AR-AG. RES. \ BUTTE COUNTY RESIDE] TOWNHOUSES + ZONE: AR-AG. RES. ZONE: AR-AG. RES. \ I BUTTE COUNTY XBBUTTE COUNTY I BUTTE COUNTY I I F. M T 50 Fu DoI TTYlNRI . W I IZONE: RI EPIC .n ~ ZONE: AR AD RES. i ZONE: AR-AC. RES. ZONE: AR-AG. RES. RESIDENTIAL TOWNHOUSES x+ s. +XxwcroH TW. ` BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY BUTTE COUNTY Surt[ l+off ------- ------ ---=-- PROPERTY UNE ' I LEGAL OESCPRIPTION: i I EXIST LANDSCAPING ALL THAT CERTAIN REAL PROPERTY I.. SITUATE IN THE STATE OF CALIFORNIA. CITY OF CHICO, DESCRIBED n I nl AS FOLLOWS: i TAX PARCEL ID: MAP 12. LOT 197, BLOCK 07 I I AOJACENT ZONING ZONE: S-R-1/2 SUBURBAN RESIDENTIAL EXISTING BUTTE COUNTY ((_) MASONIC g I TEMPLE, S La ILgBLLE 1A1710E YOWEtt SITE ENTRY Z41f1G I K D IWClE W.Op j ZONNE: A-5 AGRICULTURAL EoE BORE COUNTY (ANTENNAS O 1 1 A I ADJACENT ZONING z - I I I ZONE: S-R-1/2 SUBURBAN RESIDENTIAL BUTTE COUNTY n I NG I^ EXISTING LOT 7 GARAGE io z p n - - - E, s PROPERLY LINE 888' (1/-) 1 cn 1 3 ZONING \ i ADJACENT " ZONE: A-5 AGRICULTURAL- 801'- t \ \ LJ.] u = u ' BUTTE COUNTY \ LEASE ARIA ' I EXISTING LANDSCAPwG \ ^ o ADJACENT 20NING ZONE: A-5 AGRICULTURAL BUTTE COUNTY \ O \ \ uT o z N ' \----------------NDRD —AVE----- SITE PLAN SITE PLAN ® REVISION o SCALE: 1'= 00'-0l(11X17SZE)) clearw're® seoe IAIfL WWWGigI Inw H[ MXR Iwo xWxuNo, rA o..... EXISTING OMNI MA%SNGINBERING, LLC ANTENNAS MM SWTIELWA�r. eM. 4 o 1Aw1uT 77MT1 ' EXISTING AIV/ DISHSH ce 1 Fu. fNL 1731 T1Yl6p0 ANTENNA �.... ' EXISTING vNG PANEL WIDE MAN ANTE ANTENNAS —x—K—x—:� PROPOSED CLEARWIRE (�) i 6 EPIC w, .a.....e,,.., ~ _ W/1 a 38, Fjioy EXISTING MORE. RC O 11A3R (�3) ymE • COAX ' SHROUD .. , .� PROPOSED (A) CLEARWIRE t B IaL50N• W F]A10 EXIST. MICROWAVE ANTENNAS O 110' (i) e CONC. SLAB 7 b I EXI nNG GARAG ppyy b I I i EXISTING 130'(3) T—MOBILE LATTICE co O TOWER (DESIGNED BY ,OTHERS) [�I EXISfINO 6' HIGH CHNN— \ - UNK FENCE W/3 STRANDS w OF BARBED WIRE. F > $ N -EXISTING L7TIUTY H—FRAME EXISTING 130'(4) 7—MOBILE — V LATTICE TOWER W/ PROPOSED CL.FARWWE 1 I 3 Q ¢ c EOUIPMENT (�) SECTOR ANTENNA A—� L3] U = EXISTING CABINETS (BY OTHERS) Ak (X) MICROWAVE RRAY ANTENNA SEE NOTE BELOW PROPOSED CLEARWIRE COAX CABLE CONDUIT W/ SHROW ' RUN ON CONIC. SUB. E21 . PROPOSED CLEARWIRECABINET n . ON EXISTING EXISTING FIR TREE z CONCRETE SLAB A'3 0 3'—lY 7'—L1' 11'-0' EXISTING GARAGE (BEYOND CLEARWIRE SITE) Rc LEASE AREA Z z PROPOSED CLEARWIRE CABINET ON EXISnMG e O 34'-T CONCRETE SLAB VI z EXISTING FENCED AREA HIM, NEW CPS ANTENNA MOUNTED o LOCATE MW ANTENNAS ON EXISTING CONCRETE w 1' MW DISH AN O 16 SLAB E31 2- MW DISH AZI O 64 EXISTING 6' HIGH CNNN— N 1' MW DISH AllO 131' LINK FENCE WITH (}) 2' LLW DISH AZI O 268. STRAND BARBED WIRE o ' SEE DTL 6/A -I FOR ANTENNA ORIENTATION EXISTING UTILITY H -FRAME " ^ A-2 G EXISTING EOUIPMENT - EXISTING TOWER FOUNDATION ' (DESIGNED BY OTHERS) ENLARGED SITE PLAN AND ELEVATION ENLARGED SITE PLAN ® SCALE: 1/4' = 1'-0' (24x36 SIZE) 1 WEST ELEVATION SCALE: 1/8' = T'-0' (24x36 SIZE) 2 REVI SION o SCALE: 1/8"= 1'-0' (11x17 SIZE) SCALE: 1/16' = V -O" (11x17 SIZE) HEAk'2 CV -ciCo I f Lli'j i 20EV21 VAE*U-VIORIFC iI;vI vI r ,-s ....... .... 1 5 IIN Su -pq Pig Win ffn C:l LLJ > H CV L ClGgLMOL E.'i.o 15,2 ^���a s°11 s��HaH §� Y gs3��8gg�� B as G aq Al § g Sa'n . c 01.s C41a, '^® �: / 9 i, 3JI80M-T\.3VAT2A3 ITODH3-A3 2nOiyv79 vivoG� o s — Ir '',CV-CHCQII o vznromumwaaumcax m cool' . Ey21.b/ E'\1 %JOBIIE= S °� €m Nrn2io�z r e EVzi enE I— I h; kl- 'I felt fin .. I y' aqz €E r3a6 a 6 ��/ --€ i 511_ y.. n is IY / = I r 52i _ I � m 5 a� S I W ti N 5ry I.�w is z4eS� FR i Cb-Cl<,Od9 r M—.— oEH21 HAE'\l-WOBIf E a �� :4[� � RE 11/���""" HEAI210L,2 �C N if �i S � O D w L W N x w 80 I I W 0 S - w 1—m- Ixao w¢v