Loading...
HomeMy WebLinkAboutB19-2449 (2)BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE ,uLLe County 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot gu rantee inspections on the date requested DEVEIOPWw SERVICES Office: 530.552.3700 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B 19-2449 Issued: 7/26/2019 APN: 024-090-074 Address: 287 O'BRIEN AVE, GRIDLEY Owner: SANNAR CHARLES N & KATHRINE L Permit Type: SOLAR ROOF -RES Description: ROOF MOUNT SOLAR (15.9 KW) Flood Zone: SRA Area: SETBACKS for Zoning. AG. SRA. PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 OFFICE COPY Setbacl Bldg Permit: Pool Pl� l �iN Mrd Gas Te Address: 4� Pre -Gu Pre -DO Pool D GAS By: Date: n Pre-Pla Electric By: i Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL 'Froject Mal is a Certificate of Uccupancy for (Kesldential Unly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION 7/25/2019 yourodoFp1ans.. ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 287 Obrien Avenue Gridley, CA 95948 Job: Sannar, Charles Prepared For: Kuubix Energy, Inc. 8200 W. Doe Ave. Visalia, CA 93291 (559) 372-5002 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2016 / ASCE 7-10 2 - Wind: 110 MPH, Exposure: C 3 - Wood Species: DF -L No. 2 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. Q � No. C70784 Exp. 06/30/2021 �rV 1 F CAS 1 -844 -PV ELITE I info@yoursolarplans.com 3000 E. Birch Street Suite 201 1 Brea CA 92821 WIND LOADING ANALYSIS - Roof Components and Cladding Per ASCE 7-10 Code for Bldgs. of Any Height with Gable Roof 0 <= 450 or Monoslope Roof 8 <= 30 Using Part 1 & 3: Analytical Procedure Section 30.4 & 30.6 Job Name: ISannar, Charles I Subject: Job Number: I I Originator: I I Checker: Input Data: Wind Speed, V = 3ldg. Classification = xposure Category = Ridge Height, hr = Eave Height, he = Building Width = Building Length = Roof Type = Topo. Factor, Kzt = Direct. Factor, Kd = Enclosed? (Y/N) Hurricane Region? Component Name = Effective Area, Ae = Overhangs? (Y/N) 110 mph (Wind Map, Figure 26.5 -1A -C) II (Table 1-1 Occupancy Category) C (Sect. 26.7) 11.40 ft. (hr >= he) 8.00 ft. (he <= hr) 35.00 ft. (Normal to Building Ridge) 100.00 ft. (Parallel to Building Ridge) Gable (Gable or Monoslope) 1.00 (Sect. 26.8 & Figure 26.8-1) 0.85 (Table 26.6) Y (Sect. 28.6-1 & Figure 26.11-1) N 9.50 Fastener (Purlin, Joist, Decking, or Fastener) 936 ft.^2 (Area Tributary to C&C) N (if used, overhangs on all sides) Resulting Parameters and Coefficients: Plan hr 0 a h he L Elevation RoofAngle,0=1 11.00 Ideg. Mean Roof Ht., h = 15.00 ft. (h = (hr+he)/2, for roof angle >10 deg.) Roof External Pressure Coefficients, GCp: �I 0.30 (Fig. 30.4-2A, 30.4-213, and 30.4-2C) GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-213, and 30.4-2C) Plan hr 0 a h he L Elevation RoofAngle,0=1 11.00 Ideg. Mean Roof Ht., h = 15.00 ft. (h = (hr+he)/2, for roof angle >10 deg.) Roof External Pressure Coefficients, GCp: 3Cp Zone 1-3 Pos. = 0.30 (Fig. 30.4-2A, 30.4-213, and 30.4-2C) GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-213, and 30.4-2C) GCp Zone 2 Neg. = -1.20 (Fig. 30.4-2A, 30.4-213, and 30.4-2C) GCp Zone 3 Neg. = -2.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) Positive & Negative Internal Pressure Coefficients, GCpi (Figure 26.11-1): +GCpi Coef. = 0.18 (positive internal pressure) -GCpi Coef. = 0.18 (negative internal pressure) If z <= 15 then: Kz = 2.01 *(15/zg)^(2/a) , If z > 15 then: Kz = 2.01 *(z/zg)^(2/a) (Table 30.3-1) a = 9.50 (Table 26.9-1) zg = 900 (Table 26.9-1) Kh = 0.85 (Kh = Kz evaluated at z = h) Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd *VA 2 (Sect. 30.3.2, Eq. 30.3-1) qh = 22.35 psf qh = 0.00256*Kh*Kzt*Kd *VA 2 (qz evaluated at z = h) Design Net External Wind Pressures (Sect. 30.4 & 30.6): For h <= 60 ft.: p = qh*((GCp) - (+/-GCpi)) (psf) For h > 60 ft.: p = q*(GCp) - qi*(+/-GCpi) (psf) where: q = qh for roof qi = qh for roof (conservatively assumed per Sect. 30.6) Wind Load Tabulation for Roof Components & Cladding Component z ft.) Kh qh (psf) = Net Desi n Pressures sf !one 1,2,3 + Zone 1 - Zone 2 - Zone 3 - Fastener For z = hr: For z = he: Forz=h:l 0 0.85 22.35 10.73 -21.90 -30.84 -48.72 11.40 0.85 22.35 10.73 -21.90 -30.84 -48.72 -30.84 -30.84 8.00 0.85 22.35 10.73 -21.90 -48.72 15.00 0.85 22.35 10.73 -21.90 1 -48.72 Notes: 1. (+) and (-) signs signify wind pressures acting toward & away from respective surfaces. 2. Width of Zone 2 (edge), V= 3.50 ft. 3. Width of Zone 3 (corner), V= 3.50 ft. 4. For monoslope roofs with 0 <= 3 degrees, use Fig. 30.4-2A for 'GCp' values with 'qh'. 5. For buildings with h > 60' and 0 > 10 degrees, use Fig. 30.6-1 for'GCpi' values with 'qh'. 6. For all buildings with overhangs, use Fig. 30.4-213 for'GCp' values per Sect. 30.10. 7. If a parapet >= 3' in height is provided around perimeter of roof with 0 <= 10 degrees, Zone 3 shall be treated as Zone 2. 8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf. 9. Reference: a. ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures". b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10" by: Kishor C. Mehta and James M. Delahay (2004). Roof Components and Cladding: O; O ._.___a__ 1 tO O _.; .__..__r_ ! -..@ 1 1 ©; o 9 I , 1 t Q 1 � I I I , L I I Roof Zones for Buildings with h > 60 ft. I I ,I I O; O ._.___a__ 1 tO O _.; .__..__r_ ! -..@ 1 1 ©; o 9 1 (V 0 , 1 �7 a �. 0 0) _©d O 00 0 0 0 <= 7 deg. 7 deg. < 0 <= 27 deg. I 27 deg. < 0 <= 45 deg. Roof Zones for Buildings with h <= 60 ft. (for Gable Roofs <= 450 and Monoslope Roofs <= 30) (for Gable Roofs <= 100 and Monoslope Roofs <= 3°) `✓r.j__ 2_ t � , 1 t Q 1 I ! z ( : I I I , L I ROOF PLAN Roof Zones for Buildings with h > 60 ft. (for Gable Roofs <= 100 and Monoslope Roofs <= 3°) Gravity Load Data Panel Data Panel: TSM-300DD05A.05(II) Number of Modules: 53 Weight of PV Module 41.00 lbs PV Module Dimensions L = 65.00 in W= 39.10 in Roof Data Roof Material: Comp. Roof Dead Load QD = 10 psf PV System Dead Load QpV = 3 psf Framing Spacing sroof = 24 in Linear Dead Load WD = (QD + Qpv) * sroof = 26 plf Lag Screw Check Lumber: DF -L No. 2 Uplift Demand Design Wind Pressure Trib. Depth for Each Rail Trib. Depth for Each Rail Screw Anchor Spacing Uplift Force on Each Screw, Portrait Uplift Force on Each Screw,Landscape p = -30.8 psf (Zone 2) dpi = U2 = 2.71 ft bpi = W/2 = 1.63 ft spv = 6.00 ft (max.) UL _ (p + Qp) * dp„ * sp„ _ -452 lbs (Upwards) UW = (p + Qp„) * bp„ * sp„ _ -272 lbs (Upwards) Design Uplift Force P„pnfi = 0.6 * [Max (UL , UW )] _ -271 lbs (Upwards) Uplift Capacity NDS 2015 Adjustment Factors CD = 1.6 CM = 1 Ct = 1 SG = 0.50 Speicfic Gravity of Lumber Diameter of Lag Screw Withdraw Design /in Depth of Embeddment Total Nominal Withdrawal Value Withdrawal Design Vaule Ce, Ce9 , C9, Cd;, Ct, are not appicable SG = 0.50 NDS Supplement Table 4a D = 5/16 in 1800*SG"*W'4 = 266 lbs/in NDS 2015 12.1-1 Ip = 2.50 in W=W*Ip= 665 lbs W' = W * CD * CM * Ct = 1064 lbs NDS 2015 Table 11.3.1 Demand -Capacity Ratio P„ p„ ft / W' = 0.26 < 1 [OKAY] Beam/ Top Chord Check Lumber: DF -L No. 2 Moment Demand Span] 1 1 2 1 ::p Lenght(ft):1 11.81 7.5 Linear Dead Load wd = 26 plf Wind Load, Portrait UL= -452 lbs Wind Load, Landscape UW = -272 lbs # of Attachment per Rafter NA = 6 M(x)=Rj(x—Lj)—Pj(x—lj)— wdxZ 2 2000 — --� — 1000 -- 41 0 " E 010 5.0 0 -1000 -2000 i TT I 15.0 20.0 25.0 Length x (ft) Ma, Moment Dead 564 Ib -ft Dead + Wind 1706 Ib -ft Dead + Snow 564 Ib -ft Orientation j L(ft) pj (Ibs) Portrait 1 3.8 -452 2 7.7 -452 Portrait 3 9.2 -452 4 13.1 -452 Portrait 5 14.6 -452 6 1 18.5 -452 Moment Capacity Framing Member Size 2x6 Lumber Grade: DF -L No. 2 CM = 1 Ct = 1 Cr= 1.15 CF = 1.3 fb = 900 psi Cf, and C; are not applicable Breadth b = 1.50 in Depth d = 5.50 in Section Modulus S,, = bd2 / 6 = 7.56 in Bending Stress Capacity Fb = CM * Ct * C, * CF * fb = 1346 psi Table 4.3.1 NDS 2015 Dead 0.9 1211 psi 895 psi D 895 psi 0.74 OKAY Dead + Wind 1.6 2153 psi 2707 psi .6W+.6D 1624 psi 0.75 OKAY Dead + Snow 1.15 1547 psi 895 psi D+S 895 psi 0.58 OKAY Deflection Limit E = 1600 ksi I = 20.80 in Transient Deflection 0.371 in Transient Deflection Allowed 381 > 180 [OKAY] Total Deflection 0.742 in Total Deflection Allowed 190 > 120 [OKAY] SEISMIC WEIGHT COMPARISON / ANALYSIS - (PER CBC 2016 Part 10 Chapter 4 Section 402 PV System Weight Module Model TSM-300DD05A.05(ll) Panel Weight Wpanel = 41 lbs Number of Panels NPv = 53 Total PV System Weight WPv = Wpanel * NPv = 2173 lbs Existing Roof Weight Roof Weight Building Length Building Width Roof Area Building Perimeter Wall Height Wall weight Interior wall weight Roof Load Wall Load Total Story Weight Qp = 10.0 psf Lbuild = 100 ft Wbuild = 35 ft Abuild = 3500 ft` Pbuild = 270 ft ht = 8 ft Qweli = 15 psf Qint = 10 psf Wfloor = Abuild * Qo = 35000 lbs Nwau = ht /2 * Qwau * Pbuild + Abuild * Qint /2 = 33700 lbs Wbuild = Wfloor + Wwall = 68700 lbs Percentage Weight Increa WPv / Wb„ itd = 3.16% < 10% OKAY PHOTOVOLTAIC GENERAL NOTES 1. ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK 15. ALL PHOTOVOLTAIC SYSTEM CONDUCTORS WILL BE 90°C RATED PER NEC PERFORMED SHALL BE IN ACCORDANCE WITH THE FOLLOWING 690.31 (A), TABLE 310.15(B)(16), TABLE 310.15(B)(17). CODES: • 2016 CBC / 2015 IBC • 2016 CRC / 2015 IRC • 2016 CEC / 2014 NEC • 2016 CMC / 2015 UMC • 2016 CPC / 2015 UPC • 2016 CFC / 2015 IFC • 2016 BUILDING ENERGY EFFICIENCY STANDARDS 2. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 3. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURES INSTRUCTIONS. 4. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 5. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. 6. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES [NEC 690.9(A)] 7. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [NEC 690.611 8. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTORS SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT-CIRCUITING, OPEN -CIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING [NEC 690.181 9. PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS [NEC 690.4(C)] 10. ALL CONDUCTORS EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT [NEC 690.31(C), NEC 310.10(D)] 11. THE MODULE CONDUCTORS MUST BE TYPE USE -2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE (UL 4703 & 854 LISTED) [NEC 690.31(C)] 12. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION [NEC 690.31(B)] 13. ALL GROUNDED CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION AND SHALL BE PROPERLY COLOR IDENTIFIED AS WHITE [NEC 200.61 14. WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER [NEC 110.26] 16. ALL NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS 17. PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SERVICE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING [NEC 705.12(D)]: A. EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS [NEC 705.12(D)(1)] B: THE SUM OF AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUS -BAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE BUS -BAR RATING OR CONDUCTOR [NEC 705.12(D)(2)] C. THE INTERCONNECTION POINT SHALL BE ON THE LINE SIDE OF ALL GROUND -FAULT PROTECTION EQUIPMENT [NEC 705.12(D)(3)] D. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS- BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(D)(4)] E. CIRCUIT BREAKER, IF BACK -FED, SHALL BE SUITABLE FOR SUCH OPERATION [NEC 705.12(D)(5)] F. THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE MAIN SERVICE DISCONNECT [NEC M5.12(D)(7)] 18. METALLIC RACEWAYS OR METALLIC ENCLOSURES ARE REQUIRED WIRING METHOD FOR INSIDE A BUILDING OR PV SYSTEM [NEC 690.31(G)] 19. FLEXIBLE, FINE -STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTORS THAT ARE IDENTIFIED AND LISTED FOR SUCH USE [NEC 690.31(H) & 110.14(A)] 20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING OVER 30 VOLTS SHALL REQUIRE A TOOL TO OPEN AND SHALL BE MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING' [NEC 690.33(C), NEC 690.33(E)(2)] 21. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE -RESISTANCE RATING THAN THE BUILDING ROOF -COVERING MATERIAL 22. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR [NEC 690.46 & 250.120(C)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV SOURCE AND PV OUTPUT CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH 250.122. WHERE NO OVERCURRENT PROTECTION DEVICE IS USED IN THE CIRCUIT, AN ASSUMED OVERCURRENT DEVICE RATED AT THE PV MAX CIRCUIT CURRENT SHALL BE USED WHEN APPLYING TABLE 250.122. INCREASED IN EQUIMPMENT GROUNDING CONDUCTOR SIZE TO ADDRESS VOLTAGE DROP CONSIDERATIONS SHALL NOT BE REQUIRED. [NEC 690.451 24. FINE -STRANDED CABLES USED FOR BATTERY TERMINALS, DEVICES, AND CONNECTIONS REQUIRE LUGS AND TERMINALS LISTED AND MARKED FOR SUCH USE [NEC 690.74(A)] 25. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2016 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. (CRC 314,315) 26. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS 314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD. 27. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS (NEC 314.15) ROOFTOP -MOUNTED PHOTOVOLTAIC PANEL SYSTEMS INSTALLED ON OR ABOVE THE ROOF COVERING SHALL BE TESTED, LISTED AND IDENTIFIED WITH A FIRE CLASSIFICATION (CLASS C MINIMUM) IN ACCORDANCE WITH UL1703. AS PER 2016 CRC SECTION R902.4, AND CBC SECTIONS 1505.8 & 1505.9 AND TABLE 1505.1 0i z O w Of WLLI 00 :) � E cc _3 Z = Q Q ti t U Z U o (D-w}rn O Q J a QO2o r. U) N :L N L L) �c >wo�o = L9>M�M a xQrn;4_LU N Z 0 V � o W 0 ur) , O ooh �ZU a m L �N�QcA p !e 00 > CL U e I Page 1 OF 11 PROJECT INFORMATION NAME: SANNAR, CHARLES ADDRESS: 287 OBRIEN AVENUE, GRIDLEY, CA 95948 APN: 024090074000 JURISDICTION: GRIDLEY CONTRACTOR INFORMATION CONTRACTOR: KUUBIX ENERGY, INC ADDRESS: 8200 W DOE AVE, VISALIA, CA 93291 PHONE: 559-747-7491 LICENSE #/TYPE: C-10: 1030786 SYSTEM INFORMATION SIZE(kw): 15.900 (DC) / 14.071 (AC) MODULE TYPE: 53 TRINA SOLAR TSM-30ODD05A.05(II) INVERTERS(S): 53 ENPHASE IQ7-60-2-US INVERTER TYPE: I MICRO -INVERTER SCOPE OF WORK: INSTALL (53) ROOF MOUNTED PV SOLAR MODULES, (53) ENPHASE IQ7-60-2-US INVERTER(S)(24OV). UPGRADE MAIN SERVICE PANEL FROM 200A BUS / 200A MAIN BREAKRE TO 225A BUS / 200A MAIN BREAKER. TABLE OF CONTENTS PAGE 1 COVER PAGE PAGE 2 SITE PLAN PAGE 3 PLOT PLAN PAGE 4 SINGLE LINE DIAGRAM PAGE 5 STRUCTURAL ATTACHMENT DETAIL PAGE 6 LABELS AND WARNING SIGNAGE PAGE 7 PV MODULE SPEC SHEET PAGE 8 INVERTER SPEC SHEET PAGE 9 UL LISTING PAGE 10 GROUNDING PAGE 11 RAPID SHUTDOWN ROOFTOP -MOUNTED PHOTOVOLTAIC PANEL SYSTEMS INSTALLED ON OR ABOVE THE ROOF COVERING SHALL BE TESTED, LISTED AND IDENTIFIED WITH A FIRE CLASSIFICATION (CLASS C MINIMUM) IN ACCORDANCE WITH UL1703. AS PER 2016 CRC SECTION R902.4, AND CBC SECTIONS 1505.8 & 1505.9 AND TABLE 1505.1 0i z O w Of WLLI 00 :) � E cc _3 Z = Q Q ti t U Z U o (D-w}rn O Q J a QO2o r. U) N :L N L L) �c >wo�o = L9>M�M a xQrn;4_LU N Z 0 V � o W 0 ur) , O ooh �ZU a m L �N�QcA p !e 00 > CL U e I Page 1 OF 11 PROPERTY LINE 00 N I44 v W CO 00 4 0 -o0 3 O,o M ���CD 0 z O O -n X m M cn � o v m z z 0 M A m I � PROPERTY LINE T ,. KUUBIX ENERGY, INC 15.900 kW DC / 14.071 kW AC Project Name REVISIONS: ON � 8200 W DOE AVEC VISALIA, CA 93291 PHOTOVOLTAIC SYSTEM SANNAR, CHARLES -n 0) 287 OBRIEN AVENUE, DRAWN BY: DATE: CD PHONE: 559-747-7491 GRIDLEY, CA 95948 CSLB: C-10: 1030786 SITE PLAN 024090074000 ontractors Signature: zc 07/25/2019 SYSTEM SPECIFICATIONS SIZE(kW): 15.900 MODULE: (53) TRINA SOLAR TSM-300DD05A.05(II) INVERTER(S): (53)ENPHASE IQ7-60-2-US INVERTER TYPE: MICRO -INVERTER STRING SCHEDULE: 1 CIRCUIT(S) OF 14 MODULES 3 CIRCUIT(S) OF 13 MODULES SYSTEM WEIGHT(Ibs) 2438.00 ARRAY AREA(sq.ft) 935.41 ARRAY AZIMUTH('): 1800 LBS/SQ. FT 2.61 BUILDING SPECIFICATIONS TYPE: S.F.D STORIES: 1 BUILDING HEIGHT: 12' BUILDING SQ.FT. 3160 sq.ft ROOF SLOPE(S): 11° ROOF FRAME MEMBER: 2X6 RAFTERS O.C. SPACING: 24" MAX SPAN: 11'-9" IN BETWEEN SUPPORTS MIN LAG BOLT EMBEDMENT: 2-1/2" MOUNTING AND STANDOFF SPECIFICATIONS ROOFING MATERIAL: SINGLE LAYER COMP RACKING SYSTEM: EVEREST STANDOFF DISTANCE(IN.): 72 MOUNTING TYPE: FLUSH MOUNT TILT LEG HEIGHT (IN.) N/A HEIGHT OF PV MODULE ABOVE ROOF SURFACE: 3" TO 5" MAX CANTILEVER: 24" ROOF MOUNTED NOTES: - SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE (GROUP R3 BUILDINGS). -THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. -SOLAR PANELS SHALL BE INSTALLED WITH NO PORTION MORE THAN 18 INCHES ABOVE THE ROOF IMMEDIATELY BELOW. -IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. ADDITIONAL BUILDING DATA 0 TOTAL ARRAY AREA (SQ. FT.): 935.41 TOTAL PLAN VIEW ROOF AREA (SQ. FT.): 3160 OCCUPYING PV PERCENTAGE: 29.60% SPRINKLER SYSTEM INSTALLED (IFC 903.3.1.3) NO PROJECT COORDINATES: 39.347413,-121.674751 ROOF ACCESS POINTS PER 2016 CFC 2018 SUPPLEMENT R324 (IFC 1204) Exceptions: 1. These requirements shall not apply to structures designed and constructed in accordance with the International Residential Code. 2. These requirements shall not aDDly to roofs with slopes of 2 units vertical in 12 units horizontal or less. R324.6.1 Pathways: Not less than two minimum 36-inchwide pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. At least one pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, a minimum 36 -inch -wide pathway from the lowest roof edge to ridge shall be provided on the same roof plane as the photovoltaic arrav, on an adiacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. R324.6.2 Setback at ridge: For photovoltaic arrays occupying not more than 33 percent of the plan view total roof area, not less than an 18 -inch clear set back is required on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 33 percent of the plan view total roof area, not less than a 36 -inch clear set back is required on both sides of a horizontal ridge R324.6.2.1 Alternative setback at ridge: Where an automatic sprinkler system is installed within the dwelling in accordance with NFPA 13D setbacks at ridges shall conform with one of the following: 1. For photovoltaic arrays occupying 66 percent or less of the plan view total roof area, not less than an 18 -inch clear setback is required on both sides of a horizontal ridge. 2. For photovoltaic arrays occupying more than 66 percent of the plan view total roof area, not less than a 36 -inch clear setback is required on both sides of a horizontal ridge. N 66 Z O W of LLI W :D CT E ww10o Z J: < < UZUo W } 0j o a�Jo a ZZ 0 C) C/5 N 0 IN Q W W Y U r � ti O U) r Q F— C) i 130 �O O O 0 L6 Z r � 0 Z d H O J CL rn 0 N L0 N r` O 0 N ai U L Z rn co r >_ W ~ O 0 CQ ) a W < Cn C) Z O U LO o O m Z U m � =5N O U C YoD>aU r0 Page 3 OF 11 0 0 o a 1W O O o I O EJ 3' 3' 3'3' ------- ----------------- 71Ad 4Jtl dSW NEMA 3R JUNCTION BOX CONDUIT RUN IN -ATTIC (SEE ADDITIONAL NOTES) ADDITIONAL NOTES: �OQtZ�FESS/O�q� CIRCUITS RUN THROUGH ATTIC W/Q� ?� (N) 225A MAIN SERVICE PANEL 120/240VAC SINGLE PHASE METAL CLAD CABLE PER NEC 690.31(E) � NO. C7O784 j, AND 250.118(10) (N) 100A AC DISCONNECT 2P - NON FUSIBLE THE LOCATION OF DC * Exp. 0613012021 RACEWAYS BENEATH THE ROOF (N) ENPHASE AC COMBINER BOX 240VAC, NEMA 3R TO BE NOT CLOSER THAN AND �, 1 TO RUN PERPENDICULAR TO 10" OF ROOF DECK AS REQUIRED qTF OF CA FIRE ACCESS POINTS BY CEC 690.31 (D)(1) 7 Scale: 1" = 10' (For 11x17 Print) 66 Z O W of LLI W :D CT E ww10o Z J: < < UZUo W } 0j o a�Jo a ZZ 0 C) C/5 N 0 IN Q W W Y U r � ti O U) r Q F— C) i 130 �O O O 0 L6 Z r � 0 Z d H O J CL rn 0 N L0 N r` O 0 N ai U L Z rn co r >_ W ~ O 0 CQ ) a W < Cn C) Z O U LO o O m Z U m � =5N O U C YoD>aU r0 Page 3 OF 11 1YIIl.KV IIVVtKItK INVUI (UG JIUt) POWER: 30OW < MAX INPUT POWER OK VOLTAGE: 39.8 x 1.14 x 1 = 45.37V < 48V OK SHORT CIRCUIT: 9.77 x 1.25 = 12.21A < 15A OK WIRE CHECK FROM ABOVE TABLE ENPHASE Q CABLE CONTAINS (2) #12 THWN-2 AWG WIRES: 24.65A < 30A OK 53 TOTAL MODULES 53 TOTAL INVERTERS CIRCUIT 1 - 14 MODULES 1.1 A #6 BARE COPPER ...... GROUND- CIRCUIT 2 -13 MODULES 1.2 EQUIPMENT A #6 BARE I COPPER ----------------------------- GROUND- '_._._._._._._._._._._._._.-GROUND- CIRCUIT 3 -13 MODULES 1.2 EQUIPMENT ........ . ._._. r. #6 BARE COPPER L ........................... GROUND- CIRCUIT 4 - 13 MODULES 52 EQUIPMENT 0A -i #6 BARE COPPER L.-•_. ................ .i GROUND- INV# 1 EQUIPMENT (TYP•) PV MODULE RATINGS TRINA SOLAR BRAND AND MODEL: TSM-300DD05A.05(II) AMAX POWER [Pmax] (w): 300 MICROINVERTER TO JBOX INVERTER TYPE: [Vmpl (V): ITEM NUMBER OF MODULES ADJUSTED IN CIRCUIT TEMPERATURE CORRECTION CORRECTED Ifc (A) FOR AWG NEEDED WIRE SIZING NUMBER OF CONDUCTORS EGC SIZE CONDUIT 1.1 14 17.50 0.71 24.65 #12 THWN-2 L1, L2, G #6 ENPHASE Q CABLE 1.2 13 16.25 0.71 22.89 #12 THWN-2 L1, L2, G #6 ENPHASE Q CABLE 1YIIl.KV IIVVtKItK INVUI (UG JIUt) POWER: 30OW < MAX INPUT POWER OK VOLTAGE: 39.8 x 1.14 x 1 = 45.37V < 48V OK SHORT CIRCUIT: 9.77 x 1.25 = 12.21A < 15A OK WIRE CHECK FROM ABOVE TABLE ENPHASE Q CABLE CONTAINS (2) #12 THWN-2 AWG WIRES: 24.65A < 30A OK 53 TOTAL MODULES 53 TOTAL INVERTERS CIRCUIT 1 - 14 MODULES 1.1 A #6 BARE COPPER ...... GROUND- CIRCUIT 2 -13 MODULES 1.2 EQUIPMENT A #6 BARE I COPPER ----------------------------- GROUND- '_._._._._._._._._._._._._.-GROUND- CIRCUIT 3 -13 MODULES 1.2 EQUIPMENT ........ . ._._. r. #6 BARE COPPER L ........................... GROUND- CIRCUIT 4 - 13 MODULES 52 EQUIPMENT 0A -i #6 BARE COPPER L.-•_. ................ .i GROUND- INV# 1 EQUIPMENT (TYP•) PV MODULE RATINGS TRINA SOLAR BRAND AND MODEL: TSM-300DD05A.05(II) AMAX POWER [Pmax] (w): 300 MAX POWER -POINT VOLTAGE INVERTER TYPE: [Vmpl (V): 32.6 OPEN CIRCUIT VOLTAGE [Voc] MAX INPUT CURRENT (A): (V): 39.8 MAX POWER -POINT CURRENT MAX CONT. OUTPUT CURRENT (A►): [Imp] (A►): 9.19 SHORT CIRCUIT CURRENT [Isc] MAX POWER AT 25°C (W): (A): 9.77 MAX SERIES FUSE [OCPD] (A): 20 MAX SYSTEM VOLTAGE (V): 600 C 2.1 B 20A PV SOLAR ...... -•-• PA 20A PV SOLAR 20A PV SOLAR 20A PV SOLAR INVERTER VALUES: BRAND AND MODEL: ENPHASE IQ7-60-2-US INVERTER TYPE: MICRO -INVERTER MAX INPUT VOLTAGE (V): 48 MAX INPUT CURRENT (A): 15 NOMINAL OUTPUT VOLTAGE (V): 240 MAX CONT. OUTPUT CURRENT (A►): 1 INVERTER OCPD (A): 15 MAX POWER AT 25°C (W): 240 AMBIENT TEMPERATURE °F: -40 J -BOX TO LOAD CENTER CALCULATION ADJUSTED # ENERGIZED RACEWAY NUMBER OF ITEM (A) 31/7' FROM ROOF ADJUSTED (A) Ifc CONDUCTORS ADJUSTMENT ADJUSTED (A) AWG NEEDED CONDUCTORS IN RACEWAY FACTOR 2.1 17.50 0.71 1 24.65 1 8 0.70 1 35.21 1 #8 THWN-2 (4)L1, (4)L2, G (N)200A IN BREAKI END -FED 3.1) \D) r3.1 N ON1 T (N) 70A PV ero BREAKER OFF (N) SQUARE D F L--------- ZE:]Gj 100A, NON -FUSIBLE DU223RB A/C DISCONNECT LOAD CENTER TO MSP CALCULATION ITEM TOTAL INVERTER CONTINUOUS RESULT (A) TEMPERATURE CORRECTED (A) AWG NEEDED OPERATING TEMP (°C) OUTPUT(A) -72C TO 399C MAXIMUM VOLTAGE: CORRECTION V D 3.1 53.00 1.25 66.25 0.91 72.80 #6 THWN-2 INV #1: (N) 70A PV O BREAKER BREAKER FEEDER (N) 225A MAIN SERVICE > METER/PANEL 120/240VAC, 1 -PHASE, 3 -WIRE, 10KAIC RATING, MSP SUITABLE FOR USE WITH 60°C/75°C Cu/AI WIRE (N)200A IN BREAKI END -FED 3.1) \D) r3.1 N ON1 T (N) 70A PV ero BREAKER OFF (N) SQUARE D F L--------- ZE:]Gj 100A, NON -FUSIBLE DU223RB A/C DISCONNECT EGC/GEC PER NEC 250.122, 250.166, 690.47(C)(3), 250.64(E) SEE NOTES SYSTEM RATINGS NOMINAL SYSTEM VOLTAGE (V): VOLTAGE CORRECTION FACTOR: 240Vac AC INVERTER OUTPUT (A): 39,8 53.00 OPERATING TEMP (°C) ADJUSTED VOLTAGE: -72C TO 399C MAXIMUM VOLTAGE: 48 V MAXIMUM VOLTAGE & VOLTAGE CORRECTION FACTOR (DC SIDE) MICRO -INVERTER INPUT [CEC 690.7] LOWEST EXPECTED AMBIENT TEMPERATURE (°C): -7 °C VOLTAGE CORRECTION FACTOR: 1.14 MODULE OPEN CIRCUIT VOLTAGE: 39,8 MODULE PER MICRO -INVERTER 1 ADJUSTED VOLTAGE: 45.37 MAXIMUM VOLTAGE: 48 V M SEE NOTE 5 NUMBER OF CONDUCTORS L1, L2, N, G EGC SIZE CONDUIT Cl) O #8 3/4" EMT U) W EGC/GEC I CONDUIT #8 1 1" EMT EQUIPMENT LEGEND ITEM DESCRIPTION A (N) TRINA SOLAR 0 TSM-300DD05A.05(II) MODULE B (N) NEMA 3R JUNCTION BOX (2) O TOTAL. SEE LAYOUT. C (N) ENPHASE AC COMBINER BOX 1 Lij U to 240VAC, NEMA 3R, 10KAIC D (N) NEMA 3R 100A AC DISCONNECT W p u-) , �0, 240VAC 10,000AIC RATING, PV SOLAR BREAKER TO BE MOUNTED NON -FUSIBLE, BLADE TYPE VISIBLE J & LOCKABLE INV #1: (N) ENPHASE IQ7-60-2-US INVERTER CD W LLIco E ix W LO o Z = Q Q U Z U o a J O z 61Q I04 T c:) U)N0 U Y U) O 0 () C 0 USE ONLY A WATER PIPING GROUNDING ELECTRODE SYSTEM, AN ADDITIONAL G N O W LU Ln Q Q, 40 1 Lij U to Z NOTES: 1- ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (NEC 250.90, 250.96). 2- GROUNDING BUSHINGS ARE REQUIRED AROUND PREPUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (NEC 250.97) Y U) O 0 () OR ALL OF THE PREVIOUSLY MENTIONED). IN EXISTING ELECTRICAL SYSTEMS THAT Z 0) CD r USE ONLY A WATER PIPING GROUNDING ELECTRODE SYSTEM, AN ADDITIONAL ti � 0 O �QrntirA � 40 1 Lij U to Z Z Q LC) O L. C� W p u-) , �0, J W PV SOLAR BREAKER TO BE MOUNTED \ U J J 0 (-D Q ON THE OPPOSITE END OF THE BUSBAR FARTHEST FROM THE MAIN Q O Z E3 BREAKER FEEDER ` > C NOTES: 1- ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (NEC 250.90, 250.96). 2- GROUNDING BUSHINGS ARE REQUIRED AROUND PREPUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (NEC 250.97) 3- THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (NEC 250.64) () OR ALL OF THE PREVIOUSLY MENTIONED). IN EXISTING ELECTRICAL SYSTEMS THAT Z 0) CD r USE ONLY A WATER PIPING GROUNDING ELECTRODE SYSTEM, AN ADDITIONAL ti � 0 O �QrntirA � .PER NEC 250.53(2), A SINGLE ROD, PIPE OR PLATE ELECTRODE SHALL BE ELECTRODE OF TYPE SPECIFIED IN 250.52(A)(2) 1 Lij U to SUPPLEMENTED BY AN ADDITIONAL Z Q LC) O L. C� W p u-) , �0, EXCEPTION, IF A SINGLE ROD, PIPE OR PLATE GROUNDING ELECTRODE HAS A X Q LI JU V RESISTANCE TO EARTH OF 25 OHMS OR LESS, THE SUPPLEMENTAL ELECTRODE a m Q O J N (n 2 U G -#4 AWG CU TO UNDERGROUND METAL WATER PIPE THAT IS A MINIMUM 10 FOOT Y a0 LL U z BURIAL IN PIPE LENGTH. CONNECT GROUNDING ELECTRODE CONDUCTOR WITHIN FIVE FEET OF WHERE IT ENTERS BUILDING. 250.52(A)(1), 250.68(C). r O 0 N 3- THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (NEC 250.64) () OR ALL OF THE PREVIOUSLY MENTIONED). IN EXISTING ELECTRICAL SYSTEMS THAT Z 0) CD r 4 -THE EQUIPMENT GROUNDING CONDUCTOR MAY BE USED AS A GROUNDING ELECTRODE CONDUCTOR. (NEC 250.121 EXCEPTION, INSTALLED PER 250.6(A), II, III, VI.) 5 -INSTALLER TO IDENTIFY THE EXISTING GROUNDING ELECTRODE TYPE (I.E. DRIVEN ROD, LIFER, WATER PIPE, OR COMBINATION OF SOME () OR ALL OF THE PREVIOUSLY MENTIONED). IN EXISTING ELECTRICAL SYSTEMS THAT Z 0) CD r USE ONLY A WATER PIPING GROUNDING ELECTRODE SYSTEM, AN ADDITIONAL ti � GROUNDING ELECTRODE (LE DRIVEN ROD) SHALL BE PROVIDED. (NEC 250.50) >_ ; M NrM C �QrntirA � .PER NEC 250.53(2), A SINGLE ROD, PIPE OR PLATE ELECTRODE SHALL BE ELECTRODE OF TYPE SPECIFIED IN 250.52(A)(2) 1 Lij U to SUPPLEMENTED BY AN ADDITIONAL Z Q LC) O L. THROUGH (A)(8) SPACED NO LESS THAN 6FT APART. W p u-) , �0, EXCEPTION, IF A SINGLE ROD, PIPE OR PLATE GROUNDING ELECTRODE HAS A X Q LI JU V RESISTANCE TO EARTH OF 25 OHMS OR LESS, THE SUPPLEMENTAL ELECTRODE m J Z m rQ SHALL NOT BE REQUIRED. Q O J N (n 2 U G -#4 AWG CU TO UNDERGROUND METAL WATER PIPE THAT IS A MINIMUM 10 FOOT Y a0 LL U Page BURIAL IN PIPE LENGTH. CONNECT GROUNDING ELECTRODE CONDUCTOR WITHIN FIVE FEET OF WHERE IT ENTERS BUILDING. 250.52(A)(1), 250.68(C). -ADDITIONAL #4 AWG CONNECTION TO LIFER IF AVAILABLE PER 250.66. IF LIFER NOT AVAILABLE THEN TWO #6 AWG CU CONNECTIONS TO GROUND RODS SEPARATED 4A OF 11 OV AT 1 C1CT C CT 1(AICCnCI'l nC/1 77 NEM DATA BRAND AND MODEL: GROSS NAMEPLATE RATING (KVA): 12.720 GROSS DC NAMEPLATE RATING (kW): 15.900 NET NAMEPLATE RATING (kW): 14.071 OPERATING VOLTAGE (V): 240 POWER FACTOR (PF) RATING (%): N/A MAXIMUM PF ADJUSTMENT RANGE (%): N/A MINIMUM PF ADJUSTMENT RANGE (%): N/A SHORT CIRCUIT CURRENT (A): 53.00 PV MODULE RATINGS BRAND AND MODEL: 15.900 TRINA SOLAR TSM-300DD05A.05(II) MAX POWER [Pmax] (w): NUMBER OF INVERTER(S): 300 MAX POWER -POINT VOLTAGE [Vmp] (V): 32.6 OPEN CIRCUIT VOLTAGE [Voc] (V): 1 CIRCUIT(S) OF 14 MODULES 3 CIRCUIT(S) OF 13 MODULES 39.8 MAX POWER -POINT CURRENT [Imp] (A): 9.19 SHORT CIRCUIT CURRENT [Isc] (A): 9.77 MAX SERIES FUSE [OCPD] (A): 20 MAX SYSTEM VOLTAGE (V): 600 INVERTER VALUES: BRAND AND MODEL: ENPHASE IQ7-60-2-US TOPOLOGY: MICRO -INVERTER MAX INPUT VOLTAGE (V): 48 MAX INPUT CURRENT (A): 15 NOMINAL OUTPUT VOLTAGE (V): 240 MAX CONT. OUTPUT CURRENT (A): 1 INVERTER OCPD (A): 15 MAX POWER AT 25°C (W): 240 AMBIENT TEMPERATURE 9F: -40 SYSTEM INFORMATION SIZE(kW): 15.900 NUMBER OF MODULES: 53 NUMBER OF INVERTER(S): 53 INVERTER TYPE: MICRO -INVERTER STRING SCHEDULE: 1 CIRCUIT(S) OF 14 MODULES 3 CIRCUIT(S) OF 13 MODULES GROUNDING TYPE: GROUNDED z O W cc U Q N W H N oU) QZ d- U U� UI C)O �> w¢ O v o C�C:) °)m Ln z c) 0 N MEDIA zrn co w �ti� M }WNP- v �aoM)�� to Z WU V) O o W p , O X QtjU i m -j Z pp M 5NLox2U Ycc) >aU Page 4B OF 11 pv module Everest Solar Systems CrossRail 48-S .x� CrossRail 48-S is the latest addition to our residential product line. It has been optimized for installations with low to moderate snow loads, and can be used as a more economical solution for these markets. Y Cost effective solution for areas with snow loads under 40 psf Y 6' spans achieved under 10 psf snow load Y LL 2703 Listed System Y Available in mill or dark anodized finish Y Compatible with existing CrossRail hardware comp shingle roofing material roof rafter QROFESS/p lin support No. C70784 V' Exp. 0613012021 7 sqTF OV I\- F CA1 \E Everest Solar Systems so>Hry>re� CrossRail 48-S Technical data: 48-S Rail Connector Material: corrosion resistant aluminum and 1.811 in stainless steel [46 mm] Engineering: stamped engineering letters available for all solar states Warranty: 12 years Certification: UL 2703 Listed System for I bonding and fire 2.02jn__L —_ -y[52 I New rail connector uses only two bolts! CrossRail 48-S shown with EverFlash roof attachment 1 :gr -,r ryrtea 48-S Rail Profile 1.535 in [39 mm] I 1.890 in y [48 mm] I I Z Noce: apam oaseo on hxposure L.ace9ory o. -Son UOSSRa I engmeenng Leners tor Betanea span Cnarts ano In-211on. Table 1: Rail Selection Chart Enphau 215 Mnuntimd Yt Roof Slope 7 - 27 Degrees maml carr..» Roof Sloe 27 - 45 Degrees bW Cay Iry Clusswil48 W>I-Wll and Fknye Not(CR La Load Rail Spans - Zone 1, Exp 8 �TQ y:=� _ rtaq 1 Rail Spans - Zone 1, Exp B 3809 Ocean Ranch Blvd., Suite 111 Oceanside, CA 92056 Snow (psf) Wind (mph) 4' 6' 8' 4' 6' 8' +1.760.301.5300 110 ReG.m. EEa• suolmroEueresiSo* wE TUV.ISO ne celAsor) paaa'.t2'( 0 130 y gIhSstdv—ll.iwd [ondltinnl, including the exdpsrvp IimiteJ warranty set Troth therein. DCo^��on of M 2011.128 (rr) - 150 ) 9001:2008 150 www-everest-sclarsystems.coni LISTED vOE oetlaratlon¢y al ..... 170 110 CR 48-5 20150618-03 '7 CR 80 'o 30 � C7 0 N 150 CR 80 170 : .......................... ...... 110 CR 48-S CR 48 20 130 CR 48 150 170 ..............30 ............ 110 130 150 170 ............................... 110 40 130 150 170 .. _.._........................ 110j KEY KEY 50 130 48-S —48- 48-S _ . 150 48 170 IIII 8 Noce: apam oaseo on hxposure L.ace9ory o. -Son UOSSRa I engmeenng Leners tor Betanea span Cnarts ano In-211on. Table 1: Rail Selection Chart end / mid clamp pv module aeo.+w, ew CRAB (h) Vess'Innovatlor TW RheInI.M v0E Coalncate 2011.128(rr) -Iso (de) 9001:2008 20150618-03 L -Foot w/ hardware 2,1 to 5' Everest CrossRail hing (mastic -tape -mastic) (1) 5/16r'x 3" lag screw minimum 2-1/2" embedment Mounting systems for solar technology solar Isystem CROSSRAIL MAIN COMPONENTS 6_r Enphau 215 Mnuntimd Yt #Nrv. i . Ir l,xh ,.ns.n 41> wnfm:Ra.s,Mm cm:waa na - ,n>�I rm,>w. zx�rnrtur, maml carr..» Everest Solar Systems, LLC bW Cay Iry Clusswil48 W>I-Wll and Fknye Not(CR La C—bil 48-5 Just [ 0615 Product images am(or Owls liu putposes only. Specifications are SuhjeCt to 'W9, U OE �TQ y:=� _ rtaq 1 voE Q 3809 Ocean Ranch Blvd., Suite 111 Oceanside, CA 92056 U� voE With- nmice. All sales of nut roducts shall ha p z Bea.R.. Eaa> -`"'> aeo.++r. ESa> +1.760.301.5300 lt-4 IMI 11111 LLP ReG.m. EEa• suolmroEueresiSo* wE TUV.ISO ne celAsor) paaa'.t2'( voeonln.ce Infrl@everest-sclarsstems.com y y gIhSstdv—ll.iwd [ondltinnl, including the exdpsrvp IimiteJ warranty set Troth therein. DCo^��on of M 2011.128 (rr) - 150 ) 9001:2008 (ac) www-everest-sclarsystems.coni LISTED vOE oetlaratlon¢y al O 20150618-03 onre,m end / mid clamp pv module aeo.+w, ew CRAB (h) Vess'Innovatlor TW RheInI.M v0E Coalncate 2011.128(rr) -Iso (de) 9001:2008 20150618-03 L -Foot w/ hardware 2,1 to 5' Everest CrossRail hing (mastic -tape -mastic) (1) 5/16r'x 3" lag screw minimum 2-1/2" embedment Mounting systems for solar technology solar Isystem CROSSRAIL MAIN COMPONENTS 6_r Enphau 215 Mnuntimd Yt #Nrv. i . Ir l,xh ,.ns.n 41> wnfm:Ra.s,Mm cm:waa na - ,n>�I rm,>w. zx�rnrtur, maml carr..» � bW Cay Iry Clusswil48 W>I-Wll and Fknye Not(CR La 48) -_--- _ tt h Lwa,ww�F;.l,mrn„ 9 -arbl Sglnlza:r,> *a:ILawls Mlc Jlj,jV Na rbm>��l'+>rrarec vlJ R.Wn'Conn Sol C msYtal 41 wlw eWNlte Nane(1HnHlt Clip nna. tbx ��>'#�jr m sat .a3ab: cud Burndy UlEE6 Lug 8.0 `N'em[a nolo im J R—dy wFFR I Im 8.0 Rardwam Only :vBM:x Seel xrv.waacw logc�wu na Module End Cl, p Set .4a vaE `k: f>rtalz:lln Y W ,1Mur wrt : znp �" Nae.+an 'Nz.a Sqd lt-4 IMI 11111 LLP - M,adub Middh Cb,,lp 54 Iral.,mcmn-,nm ^--J Oak MuJuk End Ckvny a4 Ua MN[.vml `wcvMprgbnaakca4b Wiawa> as w� a,rx>r w� Dark Module Middle Clamp Set I wxw.>rrl�„n Q 00 O EVEREST SOLAR SYSTEMS CROSSRAIL PITCHED ROOF SOLUTION LU w�'t E ww�o Z =QQ� U Z U o C w).: oaw J� a- Z 0 CC4 C/5 N U Enphau 215 Mnuntimd Yt maml carr..» � bW Cay Iry Clusswil48 O Mn.v UJ I— N Jlj,jV � wlw eWNlte Nane(1HnHlt Clip nna. tbx �'' n •��1.. ,— Burndy UlEE6 Lug 8.0 `N'em[a nolo im J R—dy wFFR I Im 8.0 Rardwam Only :vBM:x Seel xrv.waacw logc�wu na .4a vaE `k: f>rtalz:lln �r lt-4 IMI 11111 LLP Lu IgI.nY SUIVeaSxl i—+' Ua MN[.vml `wcvMprgbnaakca4b Wiawa> as EVEREST SOLAR SYSTEMS CROSSRAIL PITCHED ROOF SOLUTION LU w�'t E ww�o Z =QQ� U Z U o C w).: oaw J� a- Z 0 CC4 C/5 N U � o '. ,1 ti 0 iL Qi 1 0 I- M aN �0)�� � N O W UJ I— N Jlj,jV R Fn Z m 6> U) J O Z �r U Lu L) < 00 w� O Q 00 O Z r � C7 0 N Z� Z � o '. ,1 ti 0 iL Qi 1 0 I- M aN �0)�� a W0 O L() 0 1 X3 �>+ Jlj,jV R Fn Z m 6> D N O f) Co Ycc) >a.U„ Page 5 OF 11 SOLAR ARRAY MAIN SERVICE PANEL MICRO- ►fimiA1140 7 J -BOX Xa— STANDARD LABEL SOLAR KWH METER /It 1 1--.4\ NOTE: LABELS SHOWN ARE NOT TO SCALE LABEL EVERY 10' 5.75"x 1.125" RED WITH WHITE LETTERS A WARNING: PHOTOVOLTAIC POWER SOURCE (NEC 690.31(G)(3)(4)) LABEL 5.75" x 1.125" RED WITH WHITE LETTERS B CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED (PER 2014 NEC 690.15, 705.12(D)(3)) LABEL 4 x 2" RED WITH WHITE LETTERS C 0 WARNINGs� MULTI - POWER SUPPLY SOURCES INCLUDE: UTILITY GRID, PV SOLAR (PER 2017 NEC 705.12(B)(3),2014 NEC 705.12(D)(3)) LABEL 4 x 2" RED WITH WHITE LETTERS D 0 WARNING 0 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE (PER 2017 NEC 705.12(B)(2)(c), 2014 NEC 705.12(D)(2)(3)(b)) LABEL 4" x 1" RED WITH WHITE LETTERS E k�&WARNING (PER 2017 NEC 690.13(F)(1), 705.12(B)(4)) ECTRIC BREAKER BACK FEED (2014 NEC 705.12(D)(4)) LABEL 4"x 1" RED WITH WHITE LETTERS PHOTOVOLTAIC NOTE: THIS LABEL VARIES & F IS FOR IDENTIFICATION PER kWh METER S 2017 NEC 705.12(B)(3), 2014 NEC 705.12(D)(3), 690.15 LABEL 4" x 2" RED WITH WHITE LETTERS PHOTOVOLTAIC SYSTEM G EQUIPPED WITH RAPID SHUTDOWN (2014 NEC 690.56(C)) PLACARD 5"x4.75" RED WITH WHITE LETTERS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. N 1 11 qp MAIN ELECTRIC SERVICE DISCONNECT PV SYSTEM DISCONNECT OR UTILITY OPERATION ENPHASEAC COMBINER BOX 287 OBRIEN AVENUE, GRIDLEY, CA 95948 OWARNING 0 ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Must show drawings of the property and equipment layout per NEC 890.56 0 PLACARD 4"x 4.5" RED WITH WHITE LETTERS PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT: 53.00 A OPERATING VOLTAGE: 240 V WARNING 0 ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINAL DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION (PER IFC 605.11.1, IFC 605.11.1.4, NEC 690.15 & NEC 690.14(C)(2)) DOUBLE J -BOX COVER 0 0 AC - JUNCTION BOX WARNING THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED 0 0 ALL SIGNAGE/LABELS SHALL BE IN THE FOLLOWING FORMAT: 1. WHITE LETTERING ON A RED BACKGROUND AND WEATHER RESISTANT 2. MINIMUM 3/8" LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT, NON -BOLD 5. SHALL BE IN ACCORDANCE WITH APPROPRIATE SECTIONS, TABLES, AND ARTICLES OF THE NEC, IFC, AND AHJ. NOT USED O O OO 09 vi z 0 W IY w W :)� E w W � o Z =Q Q � t U Z U o W } a Q� J� d z O ° o c/) 0c) N 2 I— /'\ U) U_ Q J 0 O O 0- NEI O N UJ s m z O LL! C� Z U) N U .- z rn toNt 00 >-W (n0 = (' > cy) 0)!• R _C to wODUo O X�QLLIV U M Jz�p � 04 C Y 0c) f , Page 6 OF 11 Mono Multi Solutions THE A L V /4 PLU5' L K'�' FRAMED 60 -CELL MODULE i (3 'tJ C L'7 � 7 L MONOCRYSTALLINE MODULE POWER OUTPUT RANGE 2. RED. 2®day MAXIMUM EFFICIENCY i el�. 0n POSITIVE POWER TOLERANCE t Fourldedln1457,TrkvSoW Istheworldsleading comprahensivesolutlons pnNIder for solarenargy. we bellewe ckae mopwatWnwittl ou rpartners is critical to skms.Tdna SoUrrwwdistributeslts PV products to over 60 coumtdesas war the wodd,Tdnaisabiatop wideexapdoralsenlw to aach custofrteri n each marketand supplement out Inrim2il e•r0abiepmducrswiththeb2cking of Trkn as a strong, bankabld partner. Weare conxttltted to riding strategic munMy bmulfkial coNaboratfon with instOws. deveiopiam cillsbutors and bthar parjrters, Comprehensive Products And System Certificates CE632L%IEU5rMLU70911E1b17MAF_C6Mr3 W 9001: Qu2Ihy Mann -gamont System 15014001: EmAronmontalManagement Systam 19014064: GmwihomglawsfmksbnsYedfimon OHSASIBM: occupation Haalthand Safaty Managertwnt9ystam R 0 �� o1ar= _. Maximize limited space with top -end efficiency • Up to 192W/mz power density tio!p r" • Low Thermal coeffidents for greater energy productJon at high operating temperatures Highly reliable duets stringent quality control • over 30In-housetests (Uv, TC, HF, and many more) • In-house testing goes well beyond certification requirements FID resistant • 100% EL double inspection • Selective emKtel: advanced surface texturing Certified to withstand the most challenging i environmental conditions .2400Pawlndload • 5400 Pa snow load • 35 mm hall sones at 97 km/h LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Wartffitty 14041 La L - I rears s la 1s zs 0 Trina Linear Warranty ShndardStepWwranty ALnL%X"ALUs' 3!71.38 PRODUCF5 POWER RANGE TSM-DD05A.08(II) 280-315W TSM-DD05A.05(II) 275-31OW DIMENSIONS OF PV MODULE(mm/inc Iles) oom.a a 992/39.1 Back View I•V CURVES OF W MODULE(305W) 100 p0 -1W 10 --- )0 40 - f to --- ,a - - o ,a zo w 4o v vdtageM - ,uncuon aax 350 60 cells (6 x 10) 4 ,p00Mfm7 Weight mxrapal• no ..alorim, 1275 I 280 I m I 295 300 AL JA 315 Power Output To lera nce-Pwx (W) e® so . - 4Aed4 W 30 Q •L t InANlag HOW TEMPERATURE RATINGS Maximum Power Voltage-Vmpp(V) 604aa a 31.7 I 31.8 I 92.2 32.5 32.6 32.9 13-0rAln Hab 133.3 a 992/39.1 Back View I•V CURVES OF W MODULE(305W) 100 p0 -1W 10 --- )0 40 - f to --- ,a - - o ,a zo w 4o v vdtageM FRAMED 60 -CELL MODULE ELECTRICAL DATA (STC) P -V CURVES OF PV MODULE(305W) 350 60 cells (6 x 10) Module Dimensions ,p00Mfm7 Weight 18.6 kg (41.0 lb) no ..alorim, 1275 I 280 I m I 295 300 305 ` 310 315 Power Output To lera nce-Pwx (W) nmy�m' so . - 010 W 30 Q •L t voltagem FRAMED 60 -CELL MODULE ELECTRICAL DATA (STC) I Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions I 1650 x 992 x 35 mm (65.0 x 39.1 x 1.339 inches) Weight 18.6 kg (41.0 lb) Glass Peak Power Watts-Pmnx(Wp)* 1275 I 280 I 285 1 290 I 295 300 305 ` 310 315 Power Output To lera nce-Pwx (W) 235 3 1000mm (39.4 inches) *5 0-5 MC4 or Amphenol LITX t l 1111 TEMPERATURE RATINGS Maximum Power Voltage-Vmpp(V) 131.4 1 31.7 I 31.8 I 92.2 32.5 32.6 32.9 ( 33.1 133.3 Maximum Power Cument-Iwp(A) 8.76 8.84 8,97 9.01 l 9.08 9.19 9.28 19.37 9.46 Open Circuit Voltage-Vcc(V) (` 138.4 1 38.4 1 38.5 f 38.9 r1 139.6 ' 39.8 40.0 ( 40.2 40.5 Short Circuit Current-Isc(A) 9.24 9.42 9.51 9.66 9.68 9.77 9.85 9.94 10.0 Module Efficiency ryn(%) 16.8 17.1 I 17.4 ( 17.7 ( 18,Q I 18,3 1 18.6 11.8.9 f 19.2 STC Irradlarice 1000W/ma, Cell Temperature 25"C.Air MassAM1.S. ' Mea sur! ng tolera nce:1390. ELECTRICAL DATA (NOCT) I Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions I 1650 x 992 x 35 mm (65.0 x 39.1 x 1.339 inches) Weight 18.6 kg (41.0 lb) Glass rt ! 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Maximum Powe r-PmAx(Wp) 205 l 209 212 f ` 216 1I 220 223 227 231 235 3 1000mm (39.4 inches) Connector MC4 or Amphenol LITX t l 1111 TEMPERATURE RATINGS MAXIMUM RATINGS !!! Maximum Power Voltage-VmpP(V) 29.1 29.4 29.5 29.9 301 30.2 30.5 30.7 30.9 Maximum PowerCurrent-Impp(A) 7.04 f 7.10 1 7.21 7.24 17.30 f 7.38 17.46 7.53 17.60 ) 111 III Open Circuit Voltage -Vac (V) 357 35.7 35.8 36.2 36.8 37.0 372 37.4 37.6 Short Circuit Current-Isc(A) 7.46 f 7.61 1 7.68 7.80 17.82 17.89 1 7.95 18.03 18.10 NOCT: Irradiance at BOOW/mT Amblent Temperature 20°C, Wind Speed IM/S. MECHANICAL DATA Solar Cells I Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions I 1650 x 992 x 35 mm (65.0 x 39.1 x 1.339 inches) Weight 18.6 kg (41.0 lb) Glass rt ! 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Backsheet i White[DDO5A.0B(II)]; Black [DD05A.05(II)] Frame Black Anodized Aluminium Alloy [DD05A.08(ll),DDOSA.O5(ID] Illi ]-Box IP 67 or IP 68 rated I Cables Photovoltaic Technology Cable4.Omma (0.006 inches2), 1000mm (39.4 inches) Connector MC4 or Amphenol LITX Fire Type Type 1 or Type 2 TEMPERATURE RATINGS MAXIMUM RATINGS NOCT(Norrinal0perating Cell Temperature) 440C(t2°C) Temperature CoefffcientofPm= 0.39%/°C Temperature Coefficient ofVoc -0.29%/°C Temperature Coefficientoflsc 0.05%/°C WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Wa rranty (please refer to product warranty fordetalis) Operational Temperature -40-851C Maximum System Voltage 1000VDC(IEC) 1000V DC (UL) Max Series Fuse Rating 15A(Power<_285W) 20A (Power 229OW) (DO NOT connect ruse in Combiner8oxwith two or more strings In parallel connection) PACKAGING CONFIGURATION Modules perbox 30 pieces Modules per40' container 840 pieces CAUTION: RFAO SAFETYAND INSTALLATION INSTRUCTIONS 11111111111111111111 ©2017 Trina SolarLimited.Allrightsreserved.Specificationsincludedinthisdatasheetaresubjecttochangewithoutnotice. VR[maisolar Version number: TSM EN -2017-D www,trinasolar,com ai Z 0 U) W Of W 00 W � 't E 52wDO �o Z 2QQti t U Z U o yW } 'ElOQ W O a Z0Q U) co ( 7 U Q� o N ?� W N �2 \U) 0 0 /- o � O �U JQr U� 0� 00 2U > W a O () O0 O 2 } Q. Z T_ � � (D 0 N r INor, r r 0) Nt 00 W 0) ~ O M ! Q co 0) r W Q d) 06LO I�Jzm iC) o>a-0 Page 001761 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ i and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 MicroTM and Enphase IQ 7+ MicroW dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ BatteryTM, and the Enphase EnlightenTM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60 -cell and 72 -cell* modules More than a million hours of testing Class II double -insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741 -SA) * The IQ 7+ Micro is required to support 72 -cell modules. ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) I07 -60 -2 -US / IQ7-60-8-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' 235W -350W+ 235W -440W+ Module compatibility 60 -cell PV modules only 60 -cell and 72 -cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27 V - 37 V 27V -45V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additic ial DC side protection required; AC side protection requires max 2 A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L -L) voltage/rangez 240 V / 208V/ 240 V / 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L -L) branch circuit3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range Relative humidity range Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Dimensions (WxHxD) Weight Cooling Approved for wet locations Pollution degree -40°C to +65°C 4% to 100% (condensing) MC4 (or Amphenol H4 UTX with additional Q -DCC -5 adapter) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA -S20 -S22 PV2 to UTX: order ECA -S20 -S25 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 lbs) Natural convection - No fans Yes PD3 Enclosure Environmental category / UV exposure rating Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at httpc_ //enphase com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN PHAS E. @ 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 LUI00 W Q "t E wwLOo Z=aQ� t U Z U C3 o Q UJW 0 d Zqt 0 04 fn 00 U Q C o G N W N oU) cc0 _U w P �Q F -U F- I1J U J LL D 0 Z W O am 00 O 0_ L6 a M r � 0 O N Page 8 OF 11 TUVRheinland Certificate Registration No.: PV 50270736 Page 23 Report No.: 15042199.117 License Holder: Changzhou Trina Solar Energy Co., Ltd. No. 2 Tian He Road Electronics Park, New District Changzhou, Jiangsu 213031 P. R. China Manufacturing Plant: Changzhou Trina Solar Energy Co., Ltd No. 2 Tian He Road Electronics Park, New District Changzhou, Jiangsu 213031 P. R. China Basis: 1Z IEC 81730.1:2004+A1tA2 IEC 61730-2:2004+A1 EN 61730-1:2007+A1+A2 EN 61730-2:2007+A1 "Photovoltaic (PV) module safety qualification" I Factory Inspection To document the consistent qualify of the product, factory inspections.are performed periodically. Product: PV Modules Type: Same as Page 1 - 7 and Page 9 -14 & Page 17 - 22 In addition: With 6" mono c -Si cells: TSM-xxxDD05A,TSM-xzxDD05A, 05,TSM-xxxDD05A.08 TSM-xxxDD05A. 50,TSM-xxxDD05A.002 TSM-xxxDD05A.082, TSM-xxxDD05A.052 (x)6(=230-280, in steps of 5, 60 cells) TSM-) xzDD05A(II),TSM-xxxDD05A.05(ii) TSM-xxxDD05A.08(11) (xxxx270-31.5, in steps.of 5, 60 cells) TSM-xxxDD14A, TSM-xxxDD14A.05, TSM-xxxDD14A.08 (xxx=280-335, in steps of 5, 72 cells) TSM-xxxDD14A(ii), TSM-xxxD D 14A.05(II) TSM-xxxDD14A.08(.In (icxx=325-375, in steps of 5, 72 cells) ILI Is, i (WRhoinland 1' 11r1 1 e yrwWAW.com 10 000002+4632 Remarks: - Valid In conjunction with TOV Rheinland certificate PV 50270713 Page i - 7 & Page 9A 4 & Page, 47 - 23. - The above listed PV modules fulfil the requirements of Application Class A (Class II acc. to IEC 61140). They may be used in PV plants at a maximum system voltage (Voc at STC) of up to 1000 VDC. -The above listed PV modules fulfil the requirements of fire rating class C, - New model names were introduced as above. - This certificate Includes further manufacturing plants as listed on Attachment List of Factories. Conditions: The product test is voluritariiy according to technical regulations. Any change of the design, materials, components or processing may require the repetition of some of the qualification tests in order to retain type approval. The certificate is valid until 01 December 2018. Rr-ftJ�_Yt"_ei�1� 28 December 2015 body 1.. -Ing. (TU) Gerd Reirrlann TOV Rheinland LGA Products GmbH, Ttilystrasse 2, 90431 NUmberg, Germany / Contact: + 49 221 806 2477 email: en ri st _,de tuv.corq CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20150626-E467724 E467724-20150108 2015 -JUNE -26 Issued to: Everest Solar Systems Ste 111 3809 Ocean Ranch Blvd Oceanside CA 92056 This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Everest Crossrail System, utilizing Crossrail 48 and 48-S rails for System Fire Classification and Bonding. Everest CrossRail System, utilizing CrossRail 80 for Bonding. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703, Outline of Investigation for Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.uI.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow -Up Service. Look for the UL Certification Mark on the product. Bruce Mahrenholz, Director North American CertitiWon Program UL LLG Any information and doctanentafon Invol Ung UL Nark eervtces aro proMded on behalf of UL LLc pu or any authorized licensee of UL For questions, plemte cattact a 1=1 UL C=omer Ser %ice Hepresettathe at htm i/w.com RtaautuMorndonsr Page 1 of 1 6 Z 0 D w Wui W E w5")o cc Z =QQti 6 U Z U o A)C uJ}ccn� o QJ� a CO QO0o co 00 N U W a W o r >„ O W �U r Q U_j DO 3:O �e F— C:) O � aLO Z m D rn 0 N Z rn ca .�., >-w�~O a t7>MItM a 1 o OL. W U LO t � m�JZ[0 � 04 U) Yao>l1U fIt Page 9 OF 11 (C) RAIL SPLICE GROUNDING EITHER METHOD 1-3 PER MANUFACTURERS INSTALL INSTRUCTIONS (1) BOND STRIP GROUNDS RAIL TO RAIL SPLICES - STAR WASHERS USED TO BOND RAIL TO BONDING STRIP RAIL 1 0) [j� (2) #6 BARE COPPER (2) SPLICE BAR, SELF -TAP SCREWS JOIN RAILS. BONDING STRIPS USED ON RAILS WITH GROUND LUGS. Q RAIL 2 9LJj' j IF SPLICE BAR HAS INTEGRATED (3) GROUND, BONDING STRIP IS NOT NECESSARY. (3) WHERE NEITHER BONDING STRIP, INTEGRATED GROUNDING SPLICE BAR, OR INTEGRATED GROUNDING MIDCLAMP ARE USED, UL 2703 APPROVED GROUND LUG WITH #6 BARE COPPER SHALL BE USED TO GROUND SPLICED RAILS. USE METHOD (2) RAIL TO RAIL BONDING' 44C o AM � COPPER JBOX GROL BUSH REQ. CONDUIT O F OMNITTIGESSIO ENCLOSURE LOCK N GROUNDING-/ U ab— CONTINUOUS BUSHING GROUND WITH LAY -IN LUG STRIP INSULATION CONDUIT GROUNDING DETAIL EQUIPMENT GROUND BUSHINGS REQ. FOR SYSTEMS OVER 250V Everest Solar Systems Bonding Mid Clamp Spec Sheet >Integrated bonding > UL 2703 component Y Fast, simple installation > Rugged design complies with a wide variety of module manufacturer's requirements > Secured in place with MK2 for single -hand installation > High strength, corrosion resistant stainless steel construction . L2 -- - 0 2 3 3 - 4 4 5 -4W 5 - 4W nark Mi�;,re, S- US00 4000349 Mid Clamp U12703 Set, Black, 30.40mm 1. Allen Bolt, Black 2. Lock Washer 3. Universal Mid Clamp, Black 4. Clamp Spring S. MK2 Slot Nut U500_4000350 Mid Clamp UL 2703,S5,BlackSet 41-50mm 1. Allen Bolt, Black 2. Lock Washer 3. Universal Mid Clamp, Black 4. Clamp Spring 5. MK2 Slot Nut MIDCLAMP TEETH MODULE PENETRATION 0 ERESrT blain Mid [lama Rntc U900_4000347 Mid Clamp UL 2703,55 Set 30.40mm 1. Allen Bolt 2. Lock Washer 3. Universal Mid Clamp 4. Clamp Spring S. MK2 Slot Nut 0500 4000348 Mid Clamp UL 2703,SS Set 41-50mm 1. Allen Bolt 2. Lock Washer 3. Universal Mid Clamp 4. Clamp Spring S. MK2 Slot Nut U� CSTB CSTB e �� oe O REG.n.ESaa VDE CEIAB (rr) Daasnnnovatlar 111V 0.neinlaM VDE Cerdric— D,,Uarauon 0 2D31-128 (fir) -.So (dc) ConrOrmlN 'Wr zo0a GROUNDING MID CLAMP EACH GROUNDING MID CLAMP PIERCES THROUGH THE ANODIZED COATINGS OF BOTH THE MODULE FRAME AND THE MOUNTING RAIL TO FORM SECURE ELECTRICAL BONDS, WHICH ARE REPEATED THROUGHOUT THE ARRAY AND AT LEAST TWICE PER PANEL. MODULE SHALL BE GROUNDED AT LEAST TWICE OVER WITH A MINIMUM OF TWO MIDCLAMPS. -EVEREST GROUNDING MID CLAMP WITH SERRATED TEETH 20150428-03 TILIZATION OF RAIL 14" SPACING TED T -BOLT BONDS TO RAIL 66 z O Lu LLI CO W :) d' E x Lu 6 Z =Q <,4, t UZUo W >:o QJ ED � d << _j co co (D N CD Z_ 0 Z) V rn V N 3 Z It 0 �w(~o a C7>C14I-CF) Q�9O in W O U LO O U mZ m 5ND02V p Yao>a.0 f% Page 10 OF 11 r sZ C .e i Z zM Z to A N. C V PA rh N l'J 19 C a -0 n C r a3r V 15.900 kW DC / 14.071 kW AC Vd� REVISIONS: i '� m m'o3 al Q a Q to MON N p 04 0303 Q 287 OBRIEN AVENUE., mm�' c3o 98 C DRAWN BY: RAPID i, @-.- PHONE: 559-747-7491 a� Qrtc Q as �+ 'n I r a O Q3 j O 7 3 faa -1'O _, C N 07/25/2019 v iV X?t N 0 rr03 d 3 r- H 0ul 7 Q i 3.d o m A S (N 't: tx C C , N K Z y C cC 2 N N �' ?tl r x. r A. t .N fJ Q 4 1A t N (A (A d ntii C A",v If �iC (�11 iCIJ D0? C A 2 rt toO aI v v as N, v v ;w C 3 N K y, � ='' tD 8C O M r7 fly' 41 g 3 N -r7 V <I1 Z d1 ate.rb 10 7 N@ t ID 7j r+ G C, �3ortt3g 0 H 3m�, C O 8 m C O eo 0 c a r18 g 3 rt- .Q C0 C R C o u=,, �'°' =10 Am fa p C_ 9 Illcccy ! to Qa M o 110 a@ 7 M 3 C C I N p on, 09 038 tD O H m G m O y d �v0 E;,:,— 0rN3to ae_3t O I b, �t n c Go ao m � a r to A Cr z 90 el CQC- % COQ %V CO- COg ei9 'a, .ei� Oft � "C05 S- O- e%0 .O- S4 NNCOCn Occe - N-O.� a.� N90 �O•�" %C �a9 C A 9. C•., C R C e� C �"► C e� C O �' C A CC K C eT G C' go C C et *90 A e� <Y .. � ., et et e* ,• e► et• .0 e► er et , e►' • rF. mg m m m m m D .m O O O al O O .m O D O �.. N N• 2 N N a O O � d O � � e � ►+ gypp+ tA+ ,rp e r sZ C .e i Z zM Z to A N. C V PA rh N l'J 19 C a -0 n C r a3r 0 Cr -q m(D0 '1ami 15.900 kW DC / 14.071 kW AC N � REVISIONS: � m m'o3 al Q a Q to MON N p N at p r 0303 Q 287 OBRIEN AVENUE., mm�' c3o 98 C DRAWN BY: RAPID Ol G)a @-.- PHONE: 559-747-7491 N O Qrtc Q as ac $ n m —� -' r 0 Q3 j O 7 3 faa -1'O _, C N 07/25/2019 N a -" H N 0 rr03 d 3 r- H 0ul 7 Q i 3.d o m 0— a 7 =ryyD�t fo 4t Ay 7o a' v fJ Q 4 1A ufv fD a gdc8 3'"K m o —M m coz Znc m `. Iro A H 2ul S93, a D0? C A 2 rt toO aI d N 3 Q A OrD 7 :6 5'0 O ;w C 3 N K y, � ='' tD 8C O M r7 v C 0 H 41 g 3 N -r7 <I1 3�'�t d1 ate.rb 10 7 N@ ID 7j r+ G C, �3ortt3g 0 H 3m�, C O 8 m C O eo 0 c a r18 3 rt- .Q C0 C R "3 a,y�p9 24 o u=,, �'°' =10 Am fa p C_ 9 Illcccy ! to Qa M o 110 a@ 7 M p on, 09 038 tD O H m G m O y d �v0 E;,:,— 0rN3to ae_3t O om b, �t n c Go ao m � a r to A KUUBIX ENERGY, INC 15.900 kW DC / 14.071 kW AC Project Name REVISIONS: 8200 W DOE AVE VISALIA, CA 93291 r, PHOTOVOLTAIC SYSTEM SANNAR, CHARLES O v 287 OBRIEN AVENUE., DRAWN BY: RAPID DATE: -n CD ca PHONE: 559-747-7491 GRIDLEY, CA 95948 —� -' CSLB: C-10: 1030786 ontractors Signature: zG SHUTDOWN 07/25/2019 024090074000 D r M 2 M D O M O X z D r r M X C M KUUBIX ENERGY, INC 15.900 kW DC / 14.071 kW AC Project Name REVISIONS: M X 8200 W DOE AVE �� VISALIA, CA 93291 PHOTOVOLTAIC SYSTEM SANNAR, CHARLES --I oPHONE: 287 OBRIEN AVENUE, DRAWN BY: MODULE SATE: 559-747-7491 GRIDLEY, CA 95948 DCD CSLB: C-10: 1030786 024090074000 ontractors Sianature: ZG LAYOUT 07/25/2019